Patient and Surgeon Radiation Exposure: Comparison of Standard and Mini-C-Arm Fluoroscopy

被引:66
作者
Giordano, Brian D. [1 ]
Baumhauer, Judith F. [1 ]
Morgan, Thomas L. [1 ]
Rechtine, Glenn R., II [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Orthopaed & Rehabil, Rochester, NY 14642 USA
关键词
PEDICLE SCREW INSERTION; IONIZING-RADIATION; INTERVENTIONAL CARDIOLOGY; ORTHOPEDIC TRAINEES; SCATTER RADIATION; ANGIOGRAPHY; FRACTURES; RISKS; STAFF;
D O I
10.2106/JBJS.H.00407
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Use of c-arm fluoroscopy is common in the operating room, outpatient clinic, and emergency department. Consequently, there is a concern regarding radiation exposure. Mini-c-arm fluoroscopes have gained popularity; however, few studies have quantified exposure during mini-c-arm imaging of a body part larger than a hand or wrist. The purpose of this study was to measure radiation exposure sustained by the patient and surgeon during the use of large and mini-c-arm fluoroscopy of an ankle specimen. Methods: Standard and mini-c-arm fluoroscopes were used to image a cadaver ankle specimen, which was suspended on an adjustable platform. Dosimeters were mounted at specific positions and angulations to detect direct and scatter radiation. Testing was conducted under various scenarios that altered the proximity of the specimen and the radiation source. We attempted to capture a range of exposure data under conditions ranging from a best to a worst-case scenario, as one may encounter in a procedural setting. Results: With all configurations tested, measurable exposure during use of the large-c-arm fluoroscope was considerably higher than that during use of the mini-c-arm fluoroscope. Patient and surgeon exposure was notably amplified when the specimen was positioned closerto the x-ray source. The exposure values that we measured during ankle fluoroscopy were consistently higher than the exposure values that have been recorded previously during hand or wrist imaging. Conclusions: Exposure of the patient and surgeon to radiation depends on the tissue density and the shape of the imaged extremity. Elevated exposure levels can be expected when larger body parts are imaged or when the extremity is positioned closer to the x-ray source. When it is possible to satisfactorily image an extremity with use of the mini c-arm, it should be chosen over its larger counterpart.
引用
收藏
页码:297 / 304
页数:8
相关论文
共 33 条
  • [1] Radiation exposure in hand surgery: Mini versus standard C-arm
    Athwal, GS
    Bueno, RA
    Wolfe, SW
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (06): : 1310 - 1316
  • [2] Radiation exposure with use of the mini-c-arm for routine orthopaedic imaging procedures
    Badman, BL
    Rill, L
    Butkovich, B
    Arreola, M
    Griend, RAV
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) : 13 - 17
  • [3] RADIATION EXPOSURE TO ANGIOGRAPHERS UNDER DIFFERENT FLUOROSCOPIC IMAGING CONDITIONS
    BOONE, JM
    LEVIN, DC
    [J]. RADIOLOGY, 1991, 180 (03) : 861 - 865
  • [4] Cancer risks attributable to low doses of ionizing radiation: Assessing what we really know
    Brenner, DJ
    Doll, R
    Goodhead, DT
    Hall, EJ
    Land, CE
    Little, JB
    Lubin, JH
    Preston, DL
    Preston, RJ
    Puskin, JS
    Ron, E
    Sachs, RK
    Samet, JM
    Setlow, RB
    Zaider, M
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (24) : 13761 - 13766
  • [5] REDUCTION OF RADIATION EXPOSURE WHILE MAINTAINING HIGH-QUALITY FLUOROSCOPIC IMAGES DURING INTERVENTIONAL CARDIOLOGY USING NOVEL X-RAY TUBE TECHNOLOGY WITH EXTRA BEAM FILTERING
    DENBOER, A
    DEFEYTER, PJ
    HUMMEL, WA
    KEANE, D
    ROELANDT, JRTC
    [J]. CIRCULATION, 1994, 89 (06) : 2710 - 2714
  • [6] DURAN EB, 2003, RAD PROTECTION SERVI
  • [7] Patient and staff dosimetry in vertebroplasty
    Fitousi, Niki T.
    Efstathopoulos, Efstathios P.
    Delis, Harry B.
    Kottou, Sofia
    Kelekis, Alexis D.
    Panayiotakis, George S.
    [J]. SPINE, 2006, 31 (23) : E884 - E889
  • [8] Fluoroscopy-induced chronic radiation skin injury -: A disease perhaps often overloohed
    Frazier, Thomas H.
    Richardson, Jeffrey B.
    Fabre, Vilma C.
    Callen, Jeffrey P.
    [J]. ARCHIVES OF DERMATOLOGY, 2007, 143 (05) : 637 - 640
  • [9] IRRADIATION OF THE SURGEON DURING PINNING OF FEMORAL FRACTURES
    GIACHINO, AA
    CHENG, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (02): : 227 - 229
  • [10] Ionising radiation during internal fixation of extracapsular neck of femur fractures
    Giannoudis, PV
    McGuigan, J
    Shaw, DL
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1998, 29 (06): : 469 - 472