Optimized multi-floor throughflow micro heat exchangers

被引:8
作者
Abdoli, Abas [1 ]
Dulikravich, George S. [1 ]
机构
[1] Florida Int Univ, Dept Mech & Mat Engn, MAIDROC Lab, Miami, FL 33174 USA
关键词
Convection heat transfer; Microchannels; Electronics cooling; High heat flux; Design optimization; Conjugate heat transfer; DESIGN OPTIMIZATION; NETWORKS;
D O I
10.1016/j.ijthermalsci.2013.12.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Multi-floor networks of straight-through counterflow liquid cooled microchannels have been investigated by performing conjugate heat transfer in a silicon substrate of size 15 x 15 x 1 mm. Two-floor and three-floor cooling configurations were analyzed with different numbers of microchannels on each floor, different diameters of the channels, and different clustering among the floors. Direction of microchannels on each floor changes by 90 degrees from the previous floor. Direction of flow in each microchannel is opposite of the flow direction in its neighbor channels. Conjugate heat transfer analysis was performed by developing a software package which uses quasi-1D thermo-fluid analysis and a fully 3D steady heat conduction analysis. These two solvers are coupled through their common boundaries representing surfaces of the cooling microchannels. Using quasi-1D solver significantly decreases overall computing time and its results are in good agreement with 3D Navier-Stokes equations solver for these types of application. Multi-objective optimization with modeFRONTIER software was performed using response surface approximations and genetic algorithm. Maximizing total amount of heat removed, minimizing coolant pressure drop, minimizing maximum temperature on the hot surface, and minimizing non-uniformity of temperature on the hot surface were four simultaneous objectives of the optimization. Maximum number of cooling microchannels on each floor, diameter ranges of the microchannels on each floor, and vertical clustering range of the floors were the specified constraints. Pareto-optimal solutions demonstrate that thermal loads of 800 W cm(-2) can be effectively managed with such multi-floor microchannel cooling networks. Two-floor microchannel configuration was also simulated with 1000 W cm(-2) uniform thermal load and shown to be feasible. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:111 / 123
页数:13
相关论文
共 26 条
[1]  
Abdoli A., 2013, ASME HEAT TRANSF C M
[2]  
[Anonymous], 200001 KANGAL IND I
[3]  
[Anonymous], 2000, OpenFOAM
[4]   EXPLICIT EQUATION FOR FRICTION FACTOR IN PIPE [J].
CHEN, NH .
INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1979, 18 (03) :296-297
[5]  
Colgan EG, 2005, P IEEE SEMICOND THER, P1
[6]  
Deb K., 1995, Complex Systems, V9, P115
[7]  
Dulikravich G. S., 2010, 14 INT HEAT TRANSF C
[8]   A Review of High-Heat-Flux Heat Removal Technologies [J].
Ebadian, M. A. ;
Lin, C. X. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (11)
[9]   Three-dimensional conjugate heat transfer in the microchannel heat sink for electronic packaging [J].
Fedorov, AG ;
Viskanta, R .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2000, 43 (03) :399-415
[10]  
Ghanbari A., 2011, Journal of Chemical Engineering and Materials Science, V2, P83