Performance assessment of the single photon emission microscope: high spatial resolution SPECT imaging of small animal organs

被引:3
作者
Mejia, J. [1 ]
Reis, M. A. [1 ,2 ]
Miranda, A. C. C. [1 ]
Batista, I. R. [1 ,2 ]
Barboza, M. R. F. [1 ]
Shih, M. C. [1 ]
Fu, G. [3 ]
Chen, C. T. [4 ]
Meng, L. J. [5 ]
Bressan, R. A. [1 ,2 ]
Amaro, E., Jr. [1 ]
机构
[1] Hosp Israelita Albert Einstein, Inst Cerebro, Sao Paulo, Brazil
[2] Univ Fed Sao Paulo, Dept Psiquiatria, Lab Interdisciplinar Neurociencias Clin, Sao Paulo, Brazil
[3] GE Global Res, Schenectady, NY USA
[4] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[5] Univ Illinois, Dept Nucl Plasma & Radiol Engn, Urbana, IL 61801 USA
基金
巴西圣保罗研究基金会;
关键词
Tomography; Preclinical imaging; Molecular imaging; Mice; CODED-APERTURE; PINHOLE; DETECTOR; DEVICE; CAMERA; SYSTEM;
D O I
10.1590/1414-431X20132764
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The single photon emission microscope (SPEM) is an instrument developed to obtain high spatial resolution single photon emission computed tomography (SPECT) images of small structures inside the mouse brain. SPEM consists of two independent imaging devices, which combine a multipinhole collimator, a high-resolution, thallium-doped cesium iodide [CsI(Tl)] columnar scintillator, a demagnifying/intensifier tube, and an electron-multiplying charge-coupling device (CCD). Collimators have 300- and 450-mm diameter pinholes on tungsten slabs, in hexagonal arrays of 19 and 7 holes. Projection data are acquired in a photon-counting strategy, where CCD frames are stored at 50 frames per second, with a radius of rotation of 35 mm and magnification factor of one. The image reconstruction software tool is based on the maximum likelihood algorithm. Our aim was to evaluate the spatial resolution and sensitivity attainable with the seven-pinhole imaging device, together with the linearity for quantification on the tomographic images, and to test the instrument in obtaining tomographic images of different mouse organs. A spatial resolution better than 500 mm and a sensitivity of 21.6 counts?.s(-1).MBq(-1) were reached, as well as a correlation coefficient between activity and intensity better than 0.99, when imaging Tc-99m sources. Images of the thyroid, heart, lungs, and bones of mice were registered using Tc-99m-labeled radiopharmaceuticals in times appropriate for routine preclinical experimentation of <1 h per projection data set. Detailed experimental protocols and images of the aforementioned organs are shown. We plan to extend the instrument's field of view to fix larger animals and to combine data from both detectors to reduce the acquisition time or applied activity.
引用
收藏
页码:936 / 942
页数:7
相关论文
共 21 条
  • [1] Accorsi R, 2001, IEEE T NUCL SCI, V48, P2411, DOI 10.1109/23.983251
  • [2] Detectors for small-animal SPECT I - Overview of technologies
    Barrett, HH
    Hunter, WCJ
    [J]. SMALL ANIMAL SPECT IMAGING, 2005, : 9 - 48
  • [3] The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging
    Beekman, Freek
    van der Have, Frans
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 (02) : 151 - 161
  • [4] Targeted multi-pinhole SPECT
    Branderhorst, Woutjan
    Vastenhouw, Brendan
    van der Have, Frans
    Blezer, Erwin L. A.
    Bleeker, Wim K.
    Beekman, Freek J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (03) : 552 - 561
  • [5] Design and performance of a multi-pinhole collimation device for small animal imaging with clinical SPECT and SPECT-CT scanners
    DiFilippo, Frank P.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (15) : 4185 - 4201
  • [6] SPEM: A state-of-the-art instrument for high resolution molecular imaging of small animal organs
    dos Reis, Marilia Alves
    Mejia, Jorge
    Batista, Ilza Rosa
    Felisa Figols de Barboza, Marycel Rosa
    Nogueira, Solange Amorim
    Wagner, Jairo
    Cabral, Francisco Romero
    Victorio Mendonca Davoglio, Petrick Marcellus
    Abilio, Vanessa Costhek
    Fu, Geng
    Li, Nan
    Meng, Ling Jian
    Shih, Ming Chi
    Chen, Chin-Tu
    Junior, Edson Amaro
    Bressan, Rodrigo Affonseca
    [J]. EINSTEIN-SAO PAULO, 2012, 10 (02): : 209 - 215
  • [7] FastSPECT II: A second-generation high-resolution dynamic SPECT imager
    Furenlid, LR
    Wilson, DW
    Chen, YC
    Kim, H
    Pietraski, PJ
    Crawford, MJ
    Barrett, HH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 631 - 635
  • [8] Small-animal SPECT and SPECT/CT: application in cardiovascular research
    Golestani, Reza
    Wu, Chao
    Tio, Rene A.
    Zeebregts, Clark J.
    Petrov, Artiom D.
    Beekman, Freek J.
    Dierckx, Rudi A. J. O.
    Boersma, Hendrikus H.
    Slart, Riemer H. J. A.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (09) : 1766 - 1777
  • [9] LANGE K, 1984, J COMPUT ASSIST TOMO, V8, P306
  • [10] Adaptive Angular Sampling for SPECT Imaging
    Li, Nan
    Meng, Ling-Jian
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (05) : 2205 - 2218