Stress-relaxation response of human menisci under confined compression conditions

被引:69
作者
Seitz, Andreas Martin [1 ]
Galbusera, Fabio [2 ]
Krais, Carina [1 ]
Ignatius, Anita [1 ]
Duerselen, Lutz [1 ]
机构
[1] Univ Ulm, Ctr Musculoskeletal Res Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
[2] IRCCS Ist Ortoped Galeazzi, Milan, Italy
关键词
Meniscus; In vitro; Finite element; Viscoelastic properties; Biphasic model; TIBIOFEMORAL CONTACT MECHANICS; CRUCIATE-DEFICIENT KNEE; HUMAN MEDIAL MENISCUS; FINITE-ELEMENT MODEL; ARTICULAR-CARTILAGE; BIOMECHANICAL PROPERTIES; VISCOELASTIC PROPERTIES; UNCONFINED COMPRESSION; MATRIX STABILIZATION; TISSUE EXPLANTS;
D O I
10.1016/j.jmbbm.2013.05.027
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The objective of this study was to determine the viscoelastic properties of human meniscal tissue during stress-relaxation under confined compression conditions. Lateral and medial longitudinal meniscus plugs of 25 donor knees (n(total)=150) were exposed to stress-relaxation tests under confined compression conditions at three compression levels (epsilon=0.1; 0.15; 0.2). Mathematical modelling using an exponential 1D-diffusion equation was used to predict the viscoelastic properties. Subsequently, finite element (FE) models were created using identical geometry, properties and test conditions as used for the in-vitro tests. Two constitutively different underlying mathematical formulations were applied to the FE models to reveal possible differences in their predictions for the relaxation response. While the first FE model mimicked the analytical model (FE1), the second FE model used a different biphasic, non-linear approach (FE2). Regression analyses showed promising coefficients of determination (R-2>0.73) between the experimental data and the predictions obtained from the diffusion equation and the two FE models. Mean aggregate modulus, predicted with the diffusion equation (H-A=64.0 kPa) was lower than those obtained with the two FE analyses (H-A,H-FE1=91.9 kPa; H-A,H-FE2=81.5 kPa). Mean hydraulic permeability (k(FE2)=1.5 x 10(-15) m(4)/N s) of the second FE2 approach was statistically lower (p<0.01) than the other permeability values (k=3.9 x 10(-15) m(4)/N s; k(FE1)= 3.4 x 10(-15) m(4)/N s). These differences are mainly due to the different underlying mathematical models used. However, when compared with corresponding literature, the results of the present study indicated good agreement. The results of the present study contribute to a better understanding of the complex nature of meniscal tissue and might also have an impact on the design of future meniscal substitutes. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:68 / 80
页数:13
相关论文
共 54 条
[21]   Effect of partial medial meniscectomy on the proprioceptive function of the knee [J].
Karahan, Mustafa ;
Kocaoglu, Baris ;
Cabukoglu, Cengiz ;
Akgun, Umut ;
Nuran, Rustu .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2010, 130 (03) :427-431
[22]   The region-dependent biphasic viscoelastic properties of human temporomandibular joint discs under confined compression [J].
Kuo, Jonathan ;
Zhang, Lixia ;
Bacroc, Thierry ;
Yao, Hai .
JOURNAL OF BIOMECHANICS, 2010, 43 (07) :1316-1321
[23]   Loading of the knee joint during activities of daily living measured in vivo in five subjects [J].
Kutzner, I. ;
Heinlein, B. ;
Graichen, F. ;
Bender, A. ;
Rohlmann, A. ;
Halder, A. ;
Beier, A. ;
Bergmann, G. .
JOURNAL OF BIOMECHANICS, 2010, 43 (11) :2164-2173
[24]   FUNDAMENTALS OF FLUID TRANSPORT THROUGH CARTILAGE IN COMPRESSION [J].
KWAN, MK ;
LAI, WM ;
MOW, VC .
ANNALS OF BIOMEDICAL ENGINEERING, 1984, 12 (06) :537-558
[25]   Meniscus and cartilage exhibit distinct intra-tissue strain distributions under unconfined compression [J].
Lai, J. H. ;
Levenston, M. E. .
OSTEOARTHRITIS AND CARTILAGE, 2010, 18 (10) :1291-1299
[26]   Superficial Zone Protein (Lubricin) in the Different Tissue Compartments of the Knee Joint: Modulation by Transforming Growth Factor Beta 1 and Interleukin-1 Beta [J].
Lee, Sang Yang ;
Niikura, Takahiro ;
Reddi, A. Hari .
TISSUE ENGINEERING PART A, 2008, 14 (11) :1799-1808
[27]   Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee [J].
Lee, Stephen J. ;
Aadalen, Kirk J. ;
Malaviya, Prasanna ;
Lorenz, Eric P. ;
Hayden, Jennifer K. ;
Farr, Jack ;
Kang, Richard W. ;
Cole, Brian J. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (08) :1334-1344
[28]   Experimental and biphasic FEM determinations of the material properties and hydraulic permeability of the meniscus in tension [J].
LeRoux, MA ;
Setton, LA .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (03) :315-321
[29]   Anisotropic response of the human knee joint meniscus to unconfined compression [J].
Leslie, BW ;
Gardner, DL ;
McGeough, JA ;
Moran, RS .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H6) :631-635
[30]   FEBio: Finite Elements for Biomechanics [J].
Maas, Steve A. ;
Ellis, Benjamin J. ;
Ateshian, Gerard A. ;
Weiss, Jeffrey A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (01)