Experimental study of a graphite disks absorber couple to a heat transformer

被引:19
作者
Olarte-Cortes, J. [1 ]
Torres-Merino, J. [2 ]
Siqueiros, J. [3 ]
机构
[1] Univ Autonoma Estado Morelos, Cuernavaca 62209, Morelos, Mexico
[2] Univ Nacl Autonoma Mexico, Fac Quim, Delegacion 04510, Coyoacan, Mexico
[3] Univ Autonoma Estado Morelos, Ctr Invest Ingn & Ciencias Aplicadas, Cuernavaca 62209, Morelos, Mexico
关键词
Absorber; Lithium bromide; Tar impregnated graphite disks; Heat transformer; FALLING FILM; VERTICAL TUBE; WATER-VAPOR; ABSORPTION; PERFORMANCE;
D O I
10.1016/j.expthermflusci.2012.11.013
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was performed on a graphite disk absorber coupled to an absorption heat transformer. The working solution used was H2O/LiBr. Due to corrosion caused to materials such as carbon steel and stainless steel with the solution H2O/LiBr, it was necessary to consider the use of another material such as tar impregnated graphite. This material has interesting properties of corrosion resistance, withstands high temperatures and presents a high thermal conductivity than the graphite without impregnation. However, there does not exist a well established methodology for designing heat exchangers with new geometries for its implementation in heat transformers. For this reason, the heat exchanger was designed with a stainless steel shell and graphite disks arranged internally in a column to carry out the absorption process. In the experimental tests carried out for a thermal load in the range from 625 to 1460 W, heat transfer coefficients in the absorber were obtained in the range from 723 to 1535 W/m(2) K. As the number of Reynolds increases from 110 to 144, the heat transfer coefficient increases up to a maximum value of 954 W/m(2) K, at Reynolds number at about 144, but when Reynolds number was increased above 147, the heat transfer coefficient decreased. (c) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:29 / 36
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 1999, WATER PURIFICATION U
[2]   Absorption of water vapour in the falling film of water-(LiBr plus LiI+LiNO3+LiCl)in a vertical tube at air-cooling thermal conditions [J].
Bourouis, M ;
Vallès, M ;
Medrano, M ;
Coronas, A .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2005, 44 (05) :491-498
[3]   Performance of a LiBr-water absorption chiller operating with plate heat exchangers [J].
de Vega, M. ;
Almendros-Ibanez, J. A. ;
Ruiz, G. .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (18-19) :3393-3407
[4]   Experimental studies on the characteristics of an absorber using LiBr/H2O solution as working fluid [J].
Deng, SM ;
Ma, WB .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (04) :293-301
[5]   Design and construction of a LiBr-water absorption machine [J].
Florides, GA ;
Kalogirou, SA ;
Tassou, SA ;
Wrobel, LC .
ENERGY CONVERSION AND MANAGEMENT, 2003, 44 (15) :2483-2508
[6]  
Greiter I., 1993, International Absorption Heat Pump Conference, V31, P225
[7]   Portable water purification system integrated to a heat transformer [J].
Huicochea, A ;
Siqueiros, J ;
Romero, RJ .
DESALINATION, 2004, 165 (1-3) :385-391
[8]  
Incropera F.P., 1998, FUNDAMENTALS HEAT MA, V4th
[9]   Experimental research on characteristics of corrosion-resisting nickel alloy tube used in triple-effect LiBr/H2O absorption chiller [J].
Jiangzhou, S ;
Wang, RZ .
APPLIED THERMAL ENGINEERING, 2001, 21 (11) :1161-1173
[10]  
Kim JK, 2002, PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, P315