Thermal analysis of chemical reactions in microchannels using highly sensitive thin-film heat-flux microsensor

被引:13
作者
Ammar, Houssein [1 ]
Garnier, Bertrand [1 ]
el Moctar, Ahmed Ould [1 ]
Willaime, Herve [2 ]
Monti, Fabrice [2 ]
Peerhossaini, Hassan [3 ]
机构
[1] UMR CNRS 6607, Lab Thermocinet, F-44306 Nantes, France
[2] CNRS ESPCI, Lab Microfluid MEMS & Nanostruct, F-75005 Paris, France
[3] Univ Paris Diderot, IED, F-75013 Paris, France
关键词
Heat-flux sensor; Reaction enthalpy; Microchannel; Micro-heat exchanger; Microreactor; Multifunctional heat exchanger;
D O I
10.1016/j.ces.2013.02.055
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Heat transfer in microfluidic devices and hence miniaturized thermal sensors has been widely analyzed in the last decade and is of great importance in applications such as micro-heat exchangers and microreactors. Here we report on some improvements in temperature measurement techniques, which can be the source of large errors due to their intrusiveness and the unreliability of conventional miniaturized thermal sensors. Gold thin films were deposited on a borosilicate substrate to create a low-cost, less intrusive 2D heat flux and temperature sensor for heat-transfer measurement along the main flow and within a microchannel. The performance of the new device for the thermal analysis inside a microreactor is illustrated with a neutralization reaction. The global heat flux released by the exothermal reaction is measured as a function of the flow rate and the reaction enthalpy is deduced. For a well studied acid-base reaction, the reaction enthalpy measured using this new heat-flux sensor had only a 5% discrepancy with the standard value, showing the efficiency of the new thin-film device. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 17 条
[1]   Bias effects on heat transfer measurements in microchannel flows [J].
Baviere, Roland ;
Favre-Marinet, Michel ;
Le Person, Stephane .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (19-20) :3325-3337
[2]  
Camps T., 2009, P S DES TEST INT PAC
[3]   Thermo-resistance based micro-calorimeter for continuous chemical enthalpy measurements [J].
Casquillas, G. Velve ;
Bertholle, F. ;
Le Berre, M. ;
Meance, S. ;
Malaquin, L. ;
Greffet, J. J. ;
Chen, Y. .
MICROELECTRONIC ENGINEERING, 2008, 85 (5-6) :1367-1369
[4]   Experimental approaches for understanding mixing performance of a minireactor [J].
Chen, GG ;
Luo, GS ;
Li, SW ;
Xu, JH ;
Wang, JD .
AICHE JOURNAL, 2005, 51 (11) :2923-2929
[6]   Rapid prototyping of microfluidic systems in poly(dimethylsiloxane) [J].
Duffy, DC ;
McDonald, JC ;
Schueller, OJA ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 1998, 70 (23) :4974-4984
[7]   A novel microreactor with 3D rotating flow to boost fluid reaction and mixing of viscous fluids [J].
Fang, Wei-Feng ;
Yang, Jing-Tang .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 140 (02) :629-642
[8]   Alternating mixing tabs in multifunctional heat exchanger-reactor [J].
Habchi, Charbel ;
Lemenand, Thierry ;
Della Valle, Dominique ;
Peerhossaini, Hassan .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2010, 49 (07) :653-661
[9]   Liquid/liquid dispersion in a chaotic advection flow [J].
Habchi, Charbel ;
Lemenand, Thierry ;
Della Valle, Dominique ;
Peerhossaini, Hassan .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2009, 35 (06) :485-497
[10]   A novel thin-film temperature and heat-flux microsensor for heat transfer measurements in microchannels [J].
Hamadi, David ;
Garnier, Bertrand ;
Willaime, Herve ;
Monti, Fabrice ;
Peerhossaini, Hassan .
LAB ON A CHIP, 2012, 12 (03) :652-658