A study on the thoron sensitivity of radon detectors available to Canadians

被引:8
作者
Chen, Jing [1 ]
Moir, Deborah [1 ]
机构
[1] Hlth Canada, Radiat Protect Bur, Ottawa, ON K1A 0K9, Canada
关键词
RN-220; MEASUREMENTS; EXPOSURE; TESTS;
D O I
10.1088/0952-4746/32/4/419
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Radon and its decay products have been identified as the second leading cause of lung cancer after tobacco smoking. Thoron is an isotope of radon. With increased awareness of radon, questions related to thoron are arising from the public. Currently, only radon detectors are commonly available to Canadian homeowners. A study on the thoron sensitivities of those radon detectors was undertaken. The average thoron sensitivity relative to radon varied from a factor of 0.012 to 0.74 for the five commonly available types of alpha track radon detectors. The potential impact of thoron sensitivity on radon test results is discussed.
引用
收藏
页码:419 / 425
页数:7
相关论文
共 15 条
[1]   Thoron: its metrology, health effects and implications for radon epidemiology: a summary of roundtable discussions [J].
Akiba, S. ;
Tokonami, S. ;
Bochicchio, F. ;
McLaughlin, J. ;
Tommasino, L. ;
Harley, N. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :477-481
[2]  
[Anonymous], 2000, SOURC EFF ION RAD SO
[3]  
[Anonymous], WHO HDB IND RAD
[4]   Estimate of annual average radon concentration in the normal living area from short-term tests [J].
Chen, J .
HEALTH PHYSICS, 2003, 85 (06) :740-744
[5]   Preliminary assessment of thoron exposure in Canada [J].
Chen, J. ;
Dessau, J. C. ;
Frenette, E. ;
Moir, D. ;
Cornett, R. J. .
RADIATION PROTECTION DOSIMETRY, 2010, 141 (04) :322-327
[6]   Preliminary results of simultaneous radon and thoron tests in Ottawa [J].
Chen, Jing ;
Tokonami, Shinji ;
Sorimachi, Atsuyuki ;
Takahashi, Hiroyuki ;
Falcomer, Renato .
RADIATION PROTECTION DOSIMETRY, 2008, 130 (02) :253-256
[7]   Assessment of test duration effect in indoor radon measurement by Monte Carlo simulations [J].
Chen, Jing ;
Moir, Deborah .
RADIATION PROTECTION DOSIMETRY, 2012, 150 (02) :248-258
[8]   The Concept of Equivalent Radon Concentration for Practical Consideration of Indoor Exposure to Thoron [J].
Chen, Jing ;
Moir, Deborah .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2012, 9 (01) :286-293
[9]   AN UPDATE ON THORON EXPOSURE IN CANADA WITH SIMULTANEOUS 222Rn AND 220Rn MEASUREMENTS IN FREDERICTON AND HALIFAX [J].
Chen, Jing ;
Moir, Deborah ;
Pronk, Toon ;
Goodwin, Terry ;
Janik, Miroslaw ;
Tokonami, Shinji .
RADIATION PROTECTION DOSIMETRY, 2011, 147 (04) :541-547
[10]   Simultaneous 222Rn and 220Rn measurements in Winnipeg, Canada [J].
Chen, Jing ;
Schroth, Eveline ;
MacKinlay, Esther ;
Fife, Ingvar ;
Sorimachi, Atsuyuki ;
Tokonami, Shinji .
RADIATION PROTECTION DOSIMETRY, 2009, 134 (02) :75-78