Standardisation of metalloimmunoassay protocols for assessment of silver nanoparticle antibody conjugates

被引:7
作者
Wilson, P. K. [1 ]
Szymanski, M. [2 ]
Porter, R. [1 ]
机构
[1] Argento Diagnost Ltd, Knowledge & Innovat Ctr, Natl Phys Lab, Teddington TW11 0LW, Middx, England
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
Troponin; Cardiac markers; Immunoassay; Metalloimmunoassay; Silver nanoparticles; Point-of-care diagnostics;
D O I
10.1016/j.jim.2012.08.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of silver nanoparticles to electrochemical metalloimmunoassays has previously been reported (Szymanski et al., 2009) and is now used in the electrochemical Argento immunoassay platform via UK Patent No. 2458420. The development of an immunoassay in this format requires the optimisation of the antibody to silver nanoparticle conjugation process. Issues such as pH, antibody concentration and other factors can affect the assay performance. In order to determine the effect of these variables it is necessary to understand and control the effects of other factors that may affect the assay signal. In this study a number of conditions which affect the assay signal were identified and methods developed to minimise variability in the assay signal, resulting in a standardised method allowing easy comparisons of silver nanoparticle conjugates prepared and assayed at different times. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 307
页数:5
相关论文
共 12 条
[1]   Ischaemic heart disease - The universal definition of myocardial infarction: a consensus document [J].
Alpert, Joseph S. ;
Thygesen, Kristian ;
Jaffe, Allan ;
White, Harvey D. .
HEART, 2008, 94 (10) :1335-1341
[2]  
Burtonwood C., 2006, 06020 NAT HLTH SERV
[3]   The use of nanoparticles in electroanalysis: an updated review [J].
Campbell, Fallyn W. ;
Compton, Richard G. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) :241-259
[4]   An electrochemical metalloimmunoassay based on a colloidal gold label [J].
Dequaire, M ;
Degrand, C ;
Limoges, B .
ANALYTICAL CHEMISTRY, 2000, 72 (22) :5521-5528
[5]   Combining different biochemical markers of myocardial ischemia does not improve risk stratification in chest pain patients compared to troponin I alone [J].
Eggers, KM ;
Oldgren, J ;
Nordenskjöld, A ;
Lindahl, B .
CORONARY ARTERY DISEASE, 2005, 16 (05) :315-319
[6]   Dynamic Light Scattering as a Powerful Tool for Gold Nanoparticle Bioconjugation and Biomolecular Binding Studies [J].
Jans, Hilde ;
Liu, Xiong ;
Austin, Lauren ;
Maes, Guido ;
Huo, Qun .
ANALYTICAL CHEMISTRY, 2009, 81 (22) :9425-9432
[7]   Evaluation of High-Sensitivity Assays for Cardiac Troponin [J].
Morrow, David A. ;
Antman, Elliott M. .
CLINICAL CHEMISTRY, 2009, 55 (01) :5-8
[8]   Standardization of troponin I measurements: an update [J].
Panteghini, Mauro ;
Bunk, David M. ;
Christenson, Robert H. ;
Katrukha, Alexei ;
Porter, Robert A. ;
Schimmel, Heinz ;
Wang, Lili ;
Tate, Jillian R. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (11) :1501-1506
[9]   A Novel, Generic, Electroanalytical Immunoassay Format Utilising Silver Nano-Particles as a Bio-Label [J].
Porter, Robert ;
Kabil, Alena ;
Forstern, Camilla ;
Slevin, Christopher ;
Kouwenberg, Katherine ;
Szymanski, Mateusz ;
Birch, Brian .
JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2009, 30 (04) :428-440
[10]  
Schreiber D. H., 2009, USE CARDIAC MARKERS