Margins between clinical target volume and planning target volume for electron beam therapy

被引:5
作者
Thomas, SJ [1 ]
机构
[1] Addenbrookes Hosp, Cambridge CB2 2QQ, England
关键词
D O I
10.1259/bjr/70202978
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When growing a clinical target volume (CTV) to a planning target volume (PTV), it is necessary to determine suitable margins, based on the systematic and random uncertainties. For electron therapy, where treatments are usually given with single fields, the factors affecting the margin are very different in the direction of the incident beam from those in the perpendicular directions, since set-up errors do not affect the depth of the 90% isodose. For a typical case, the perpendicular margins are three times the margin in the direction of the incident beam. This gives rise to problems with volume growing algorithms if the beam axis is not aligned with a cardinal axis.
引用
收藏
页码:244 / 247
页数:4
相关论文
共 50 条
  • [31] Definition of Planning Target Volume Margins for Carotid Sparing Intensity Modulated Radiation Therapy for Early Glottis Cancer
    Gujral, D. M.
    Long, M.
    Roe, J.
    Harrington, K.
    Nutting, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E314 - E314
  • [32] Correcting rotational error in rectal cancer radiation therapy: Can planning target volume margins be safely reduced?
    Seah, Vivian
    Dundas, Kylie
    Hudson, Felicity
    Surjan, Yolanda
    Bartlett, Rebecca
    Ko, Rebecca
    Smith, Sandie
    Arumugam, Sankar
    Johnston, Meredith
    Wong, Karen
    Lee, Mark
    [J]. JOURNAL OF MEDICAL RADIATION SCIENCES, 2022, 69 (04) : 473 - 483
  • [33] Defining clinical target volume
    Mirimanoff, RO
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S134 - S134
  • [34] Nonuniform Planning Target Volume Margins for Prostate Bed on the Basis of Surgical Clips on Daily Cone Beam Computed Tomography
    Song, Haijun
    Salama, Joseph K.
    Lee, William Robert
    Wu, Qiuwen
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2019, 4 (01) : 186 - 190
  • [35] Positioning error and expanding margins of planning target volume with kilovoltage cone beam computed tomography for prostate cancer radiotherapy
    Wang, Gang
    Wang, Wen-Ling
    Liu, Yi-Qun
    Dong, Hong-Min
    Hu, Yin-Xiang
    [J]. ONCOTARGETS AND THERAPY, 2018, 11 : 1981 - 1988
  • [36] Dose escalation resulting from reduced margins used to generate the planning target volume
    Nelson, C
    Starkschall, G
    Chang, J
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1946 - 1946
  • [37] Estimated limits of IMRT dose escalation using varied planning target volume margins
    Goulet, Christopher C.
    Herman, Michael G.
    Hillman, David W.
    Davis, Brian J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14) : 3777 - 3788
  • [38] Current challenges in clinical target volume definition: Tumour margins and microscopic extensions
    Moghaddasi, Leyla
    Bezak, Eva
    Marcu, Loredana G.
    [J]. ACTA ONCOLOGICA, 2012, 51 (08) : 984 - 995
  • [39] Indigenous groin board immobilization reduces planning target volume margins in groin radiotherapy
    Krishnatry, Rahul
    Mangaj, Akshay
    Bhajbhuje, Rajesh
    Murthy, Vedang
    [J]. JOURNAL OF MEDICAL PHYSICS, 2021, 46 (02) : 88 - 93
  • [40] Investigation on cone-beam computed tomography-based liver cancer radiotherapy clinical target volume planning target volume margin and analysis of dosimetric differences
    Zhenghuan, Li
    Manya, Wu
    Fantu, Kong
    Jie, Dong
    Yuan, Cheng
    Qinghe, Peng
    Junyue, Shi
    Huamei, Yan
    Xiangying, Xu
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (02)