Margins between clinical target volume and planning target volume for electron beam therapy

被引:5
|
作者
Thomas, SJ [1 ]
机构
[1] Addenbrookes Hosp, Cambridge CB2 2QQ, England
关键词
D O I
10.1259/bjr/70202978
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
When growing a clinical target volume (CTV) to a planning target volume (PTV), it is necessary to determine suitable margins, based on the systematic and random uncertainties. For electron therapy, where treatments are usually given with single fields, the factors affecting the margin are very different in the direction of the incident beam from those in the perpendicular directions, since set-up errors do not affect the depth of the 90% isodose. For a typical case, the perpendicular margins are three times the margin in the direction of the incident beam. This gives rise to problems with volume growing algorithms if the beam axis is not aligned with a cardinal axis.
引用
收藏
页码:244 / 247
页数:4
相关论文
共 50 条
  • [1] Combined Recipe for Clinical Target Volume and Planning Target Volume Margins
    Stroom, Joep
    Gilhuijs, Kenneth
    Vieira, Sandra
    Chen, Wei
    Salguero, Javier
    Moser, Elizabeth
    Sonke, Jan-Jakob
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 88 (03): : 708 - 714
  • [2] Target volume margins for lung cancer: Internal target volume/clinical target volume
    Jouin, A.
    Pourel, N.
    CANCER RADIOTHERAPIE, 2013, 17 (5-6): : 428 - 433
  • [3] Clinical to planning target volume margins in prostate cancer radiotherapy
    Ramiandrisoa, F.
    Duverge, L.
    Castelli, J.
    Nguyen, T. D.
    Servagi-Vernat, S.
    de Crevoisier, R.
    CANCER RADIOTHERAPIE, 2016, 20 (6-7): : 629 - 639
  • [4] Deriving Planning Target Volume Margins for Intracranial Stereotactic Radiation Therapy
    Li, W.
    Craig, T.
    Cho, Y.
    Wang, A.
    Jaffray, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S732 - S732
  • [5] The effect of image-guided radiation therapy on the margin between the clinical target volume and planning target volume in lung cancer
    Liang, Jun
    Li, Minghui
    Zhang, Tao
    Han, Wei
    Chen, Dongfu
    Hui, Zhouguang
    Lv, Jima
    Zhang, Zhong
    Zhang, Yin
    Zhang, Liansheng
    Zheng, Rong
    Dai, Jianrong
    Wang, Luhua
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2014, 61 (01): : 30 - 37
  • [6] The Effects of the Shape and Size of the Clinical Target Volume on the Planning Target Volume Margin
    Zheng, Buhong
    Huang, Zhiyu
    Li, Jinluan
    PLOS ONE, 2014, 9 (10):
  • [7] Does the Shape and Size of Clinical Target Volume Affect the Planning Target Volume Margin?
    Zheng, B.
    Liang, J.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [8] Optical Surface-guided Radiation Therapy for Upper and Lower Limb Sarcomas: An Analysis of Setup Errors and Clinical Target Volume-To-Planning Target Volume Margins
    Zhang, Yan-Xin
    Huan, Fu-Kui
    Wan, Bao
    Li, Zhao-Hui
    Li, Wei
    Zhu, Geng-Qiang
    Wang, Zhi-Wei
    Chen, Huan
    Hou, Lu
    Jing, Hao
    Wang, Shu-Lian
    Lu, Ning-Ning
    ADVANCES IN RADIATION ONCOLOGY, 2024, 9 (08)
  • [9] Determination of Optimal Clinical Target Volume to Planning Target Volume Margins for Conformal Radiotherapy Planning using Image Guidance System in Rectal Cancer in Prone Position
    Bansal, Shashank
    Bhattacharyya, Mouchumee
    Kalita, Apurba Kumar
    Singh, Moirangthem Nara
    Sunku, Rubu
    Medhi, Partha Pratim
    Bora, Ghritashee
    JOURNAL OF MEDICAL PHYSICS, 2019, 44 (01) : 65 - 67
  • [10] Prostate cancer radiation therapy with reduced planning target volume (PTV) margins.
    Sun, Kelly
    Brand, Timothy
    Tinnel, Brent
    Kathpal, Madeera
    Ninneman, Stephanie
    Hughs, Grant
    Halligan, John B.
    Brown, Michael
    Brooks, Joseph P.
    Macdonald, Dusten
    JOURNAL OF CLINICAL ONCOLOGY, 2015, 33 (07)