Poly(o-phenylenediamine)-carried nanogold particles as signal tags for sensitive electrochemical immunoassay of prolactin

被引:47
|
作者
Chen, Huafeng [1 ,2 ]
Cui, Yuling [1 ,2 ]
Zhang, Bing [1 ,2 ]
Liu, Bingqian [1 ,2 ]
Chen, Guonan [1 ,2 ]
Tang, Dianping [1 ,2 ]
机构
[1] Fuzhou Univ, Dept Chem, Key Lab Anal & Detect Food Safety, Minist Educ, Fuzhou 350108, Peoples R China
[2] Fuzhou Univ, Dept Chem, Fujian Prov Key Lab Anal & Detect Technol Food Sa, Fuzhou 350108, Peoples R China
基金
美国国家科学基金会; 中国国家自然科学基金; 高等学校博士学科点专项科研基金;
关键词
Electrochemical immunoassay; Nanogold-assembled; poly(o-phenylenediamine) microspheres; Nanolabels; Prolactin; CARCINOEMBRYONIC ANTIGEN; GOLD NANOPARTICLES; AMPLIFICATION; IONS; DNA; TRANSDUCTION; ENHANCEMENT; POLYMERS;
D O I
10.1016/j.aca.2012.03.052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel class of redox-active molecular tags, poly(o-phenylenediamine)-carried nanogold particles (GPPDs), was first synthesized and functionalized with horseradish peroxidase-anti-prolactin conjugates (HRP-anti-PRL). Thereafter, a specific sandwich-type electrochemical immunoassay was designed for determination of prolactin (PRL) by using GPPD-labeled HRP-anti-PRL conjugates as molecular tags on anti-PRL antibody-modified glassy carbon electrode. Compared with pure gold nanoparticles and poly(o-phenylenediamine) microspheres, the as-prepared GPPDs increased the surface coverage of the nanostructures, and enhanced the immobilization amount of biomolecules. Several labeling protocols compromising GPPD-labeled HRP-anti-PRL, nanogold particles-labeled HRP-anti-PRL and poly(o-phenylenediamine) microspheres-labeled HRP-anti-PRL, were investigated for detection of PRL, and improved analytical features were obtained with the GPPD-based strategy. With the GPPD labeling method, dependence of the electrochemical signals on the incubation time and pH of the assay solution were also studied. The strong attachment of HRP-anti-PRL to the GPPDs resulted in a good repeatability and intermediate reproducibility down to 9.8%. The dynamic concentration range spanned from 0.5 to 180 ng mL(-1) PRL with a detection limit of 0.1 ng mL(-1) at the 3S(blank) level. No significant differences at the 95% confidence level were encountered in the analysis of 10 spiked blank cattle serum samples between the developed immunoassay and enzyme-linked immunosorbent assay method for determination of PRL (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 25
页数:8
相关论文
共 18 条
  • [1] Nanogold-polyaniline-nanogold microspheres-functionalized molecular tags for sensitive electrochemical immunoassay of thyroid-stimulating hormone
    Cui, Yuling
    Chen, Huafeng
    Hou, Li
    Zhang, Bing
    Liu, Bingqian
    Chen, Guonan
    Tang, Dianping
    ANALYTICA CHIMICA ACTA, 2012, 738 : 76 - 84
  • [2] Poly(o-phenylenediamine) nanosphere-conjugated capture antibody immobilized on a glassy carbon electrode for electrochemical immunoassay of carcinoembryonic antigen
    Xu, Ti-Sen
    Li, Xiang-Yong
    Xie, Zhao-Hui
    Li, Xue-Gui
    Zhang, Hai-Ying
    MICROCHIMICA ACTA, 2015, 182 (15-16) : 2541 - 2549
  • [3] Enzyme-induced Fenton reaction coupling oxidation of o-phenylenediamine for sensitive and specific immunoassay
    Liu, Bingqian
    Shi, Weiping
    Yang, Yani
    Cai, Jie
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2020, 24 (03) : 633 - 640
  • [4] Revisiting the Structure and Electrochemical Performance of Poly(o-phenylenediamine) as an Organic Cathode Material
    Zhang, Xi
    Li, Gaofeng
    Wang, Junxiao
    Chu, Jun
    Wang, Feng
    Hu, Zijun
    Song, Zhiping
    ACS APPLIED MATERIALS & INTERFACES, 2022, 14 (24) : 27968 - 27978
  • [5] Poly(o-phenylenediamine) nanosphere-conjugated capture antibody immobilized on a glassy carbon electrode for electrochemical immunoassay of carcinoembryonic antigen
    Ti-Sen Xu
    Xiang-Yong Li
    Zhao-Hui Xie
    Xue-Gui Li
    Hai-Ying Zhang
    Microchimica Acta, 2015, 182 : 2541 - 2549
  • [6] Sensitive electrochemical immunoassay with signal enhancement based on nanogold-encapsulated poly(amidoamine) dendrimer-stimulated hydrogen evolution reaction
    Sun, Ai-Li
    ANALYST, 2015, 140 (23) : 7948 - 7954
  • [7] The preparation and characterization of poly(o-phenylenediamine)/gold nanoparticles interface for immunoassay by surface plasmon resonance and electrochemistry
    Wang, Qiong
    Tang, Hao
    Xie, Qingji
    Jia, Xueen
    Zhang, Youyu
    Tan, Liang
    Yao, Shouzhuo
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 63 (02) : 254 - 261
  • [8] Sensitive and selective determination of dopamine by electrochemical sensor based on molecularly imprinted electropolymerization of o-phenylenediamine
    Wu, Dan
    Li, He
    Xue, Xiaodong
    Fan, Haixia
    Xin, Qiang
    Wei, Qin
    ANALYTICAL METHODS, 2013, 5 (06) : 1469 - 1473
  • [9] Composite layers consisting of polyaniline and poly(o-phenylenediamine): Electrochemical deposition, electrochromic and electrocatalytic properties
    Duic, Lj.
    Rokovic, M. Kraljic
    Mandic, Z.
    POLYMER SCIENCE SERIES B, 2010, 52 (7-8) : 431 - 437
  • [10] Electrochemical aptasensor for mucin 1 based on dual signal amplification of poly(o-phenylenediamine) carrier and functionalized carbon nanotubes tracing tag
    Chen, Xiaojun
    Zhang, Qi
    Qian, Chunhua
    Hao, Ning
    Xu, Lin
    Yao, Cheng
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 485 - 492