Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 50 条
  • [41] A patient-specific 3D model of the knee to compare the femoral rollback before and after total knee arthroplasty (TKA)
    Mercader, Alexandra
    Roettinger, Timon
    Bigdeli, Amir
    Lueth, Tim C.
    Roettinger, Heinz
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2021, 8 (01)
  • [42] Clinical outcomes and patient satisfaction following revision of failed unicompartmental knee arthroplasty to total knee arthroplasty are as good as a primary total knee arthroplasty
    Lim, Jason Beng Teck
    Pang, Hee Nee
    Tay, Keng Jin Darren
    Chia, Shi-lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE, 2019, 26 (04) : 847 - 852
  • [43] The use of patient-specific instruments does not reduce blood loss during minimally invasive total knee arthroplasty?
    Emmanuel Thienpont
    Irina Grosu
    Frederic Paternostre
    Pierre-Emmanuel Schwab
    Jean Cyr Yombi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2055 - 2060
  • [44] Patient-specific instrumentation in total knee arthroplasty: a review of the current literature
    Schoenthaler, Wolfgang
    Dauwe, Jan
    Holzer, Lukas A.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 299 - 306
  • [45] Patient-Specific Instrumentation Does Not Improve Accuracy in Total Knee Arthroplasty
    Shen, Chong
    Tang, Zhi-Hong
    Hu, Jun-Zu
    Zou, Guo-Yao
    Xiao, Rong-Chi
    Yan, Dong-Xue
    ORTHOPEDICS, 2015, 38 (03) : E178 - E188
  • [46] Patient-specific instrumentation and custom total knee implants in total knee arthroplasty
    Isaacson, Mark
    Bunn, Kevin
    Incavo, Stephen
    CURRENT ORTHOPAEDIC PRACTICE, 2015, 26 (03): : 224 - 227
  • [47] Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty
    Gong, Song
    Xu, Weihua
    Wang, Ruoyu
    Wang, Zijian
    Wang, Bo
    Han, Lizhi
    Chen, Guo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2019, 27 (04) : 1083 - 1095
  • [48] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Sébastien Parratte
    Guillaume Blanc
    Thomas Boussemart
    Matthieu Ollivier
    Thomas Le Corroller
    Jean-Noël Argenson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2213 - 2219
  • [49] Patient-Specific Instrumentation Does Not Improve Alignment in Total Knee Arthroplasty
    Russell, Robert
    Brown, Timothy
    Huo, Michael
    Jones, Richard
    JOURNAL OF KNEE SURGERY, 2014, 27 (06) : 501 - 504
  • [50] Patient specific instrumentation in total knee arthroplasty: a state of the art
    Mattei, Lorenzo
    Pellegrino, Pietro
    Calo, Michel
    Bistolfi, Alessandro
    Castoldi, Filippo
    ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (07)