Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 50 条
  • [31] Total Knee Arthroplasty Using Patient-specific Blocks after Prior Femoral Fracture without Hardware Removal
    Vaishya, Raju
    Vijay, Vipul
    Agarwal, Amit K.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 154 - 160
  • [32] Biomechanical study of using patient-specific diaphyseal femoral cone in revision total knee arthroplasty (rTKA)
    Nourishirazi, Reza
    Moradkhani, Ghazaleh
    SharafatVaziri, Arash
    Nematy, Hamidreza
    Shayan-moghadam, Ramin
    Karimpour, Morad
    JOURNAL OF ORTHOPAEDICS, 2024, 57 : 65 - 71
  • [33] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [34] Accuracy and efficacy of osteotomy in total knee arthroplasty with patient-specific navigational template
    Gan, Yudong
    Ding, Jing
    Xu, Yongqing
    Hou, Chunlin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2015, 8 (08): : 12192 - 12201
  • [35] Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty
    Okada, Yohei
    Teramoto, Atsushi
    Suzuki, Tomoyuki
    Kii, Yuichiro
    Watanabe, Kota
    Yamashita, Toshihiko
    KNEE, 2017, 24 (06) : 1492 - 1497
  • [36] Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Zanini, Beatrice
    Compagnoni, Riccardo
    Ferrua, Paolo
    Randelli, Pietro
    JOURNAL OF KNEE SURGERY, 2019, 32 (06) : 483 - 489
  • [37] Patient-specific instrumentation in total knee arthroplasty
    Mathis, Dominic T.
    Hirschmann, Michael T.
    ARTHROSKOPIE, 2021, 34 (05) : 342 - 350
  • [38] Patient-Specific Instrumentation in Total Knee Arthroplasty
    Jauregui, Julio J.
    Cherian, Jeffrey J.
    Kapadia, Bhaveen H.
    Banerjee, Samik
    Issa, Kimona
    Harwin, Steven F.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2014, 27 (03) : 177 - 183
  • [39] Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty
    Asada, Shigeki
    Mori, Shigeshi
    Matsushita, Tetsunao
    Nakagawa, Koichi
    Tsukamoto, Ichiroh
    Akagi, Masao
    KNEE, 2014, 21 (06) : 1238 - 1243
  • [40] Total knee arthroplasty with the use of patient specific instruments. The VISIONAIRE system
    Tibesku, C. O.
    ORTHOPADE, 2016, 45 (04): : 286 - 293