Revision of partial knee to total knee arthroplasty with use of patient-specific instruments results in acceptable femoral rotation

被引:5
作者
Schotanus, Martijn G. M. [1 ]
Thijs, Elke [1 ]
Boonen, B. [1 ]
Kerens, B. [2 ]
Jong, B. [3 ]
Kort, Nanne P. [1 ]
机构
[1] Zuyderland Med Ctr, Dept Orthoped Surg & Traumatol, Dr H vd Hoffpl 1, NL-6162 AG Sittard Geleen, Netherlands
[2] AZ St Maarten, Mechelen, Belgium
[3] Zuyderland Med Ctr, Dept Radiol, Sittard Geleen, Netherlands
关键词
Patient-specific instruments; PSI; Revision; Partial knee arthroplasty; PKA; Unicompartmental knee arthroplasty; UKA; Total knee arthroplasty; TKA; CT-based; Outliers; Planning; Alignment; ALIGNMENT; REPLACEMENT; METAANALYSIS; CT; COMPONENTS; OUTCOMES; LEVEL; MRI;
D O I
10.1007/s00167-017-4674-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patient-specific instruments (PSI) were initially developed for the alignment of both total knee- (TKA) and partial knee arthroplasty (PKA). We hypothesize that CT-based PSI for PKA-to-TKA revision surgery can restore biomechanical limb alignment and prosthetic component positioning in vivo as calculated pre-operatively, resulting in a limited percentages of outliers. An imaging analysis was performed using CT-based 3D measurement methods based on a pre- and post-revision CT scan. Imaging data were gathered on 10 patients who were operated for PKA-to-TKA revision with the use of PSI based on CT imaging. The planned femur and tibia component position in vivo were compared with the pre-revision planned component position. Outliers were defined as deviations > 3.0A degrees from pre-revision planned position for the individual implant components. Adjustments (e.g. resection level and implant size) during surgery were recorded. The HKA axis was restored accurately in all patients with a mean post-operative HKA axis of 178.1A degrees (1.4A degrees). Five femoral (2 varus, 2 internal rotation and 1 extension) and 14 tibial guides (2 varus, 6 anterior slope, 3 internal rotation and 3 external rotation) on a total of 60 outcome measures were identified as outliers. During surgery, an intraoperative tibial resection of 2 mm extra was performed in three patients. In 80 and 70% for, respectively, the femur and tibia, the surgeon-planned size was implanted during surgery. All patient-specific guides fitted well in all patients. No intraoperative or post-operative complications related to surgery were registered. This study introduced a unique new concept regarding PSI, PKA-to-TKA revision surgery. Based on the results, we were unable to fully confirm our hypothesis. PSI as a "new" tool for PKA-to-TKA revision surgery appears to be an accurate tool for the alignment of the TKA femur component. The tibial guide seems more susceptible to errors, resulting in a substantial percentage of outliers. Prospective cohort study, Level II.
引用
收藏
页码:1656 / 1661
页数:6
相关论文
共 31 条
[1]  
Bargren JH, 1973, CLIN ORTHOP RELAT R, V173, P178
[2]   Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation [J].
Berhouet, J. ;
Beaufils, P. ;
Boisrenoult, P. ;
Frasca, D. ;
Pujol, N. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2011, 97 (07) :699-704
[3]   Patient-specific positioning guides for total knee arthroplasty: no significant difference between final component alignment and pre-operative digital plan except for tibial rotation [J].
Boonen, Bert ;
Schotanus, Martijn G. M. ;
Kerens, Bart ;
Hulsmans, Frans-Jan ;
Tuinebreijer, Wim E. ;
Kort, Nanne P. .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (09) :2809-2817
[4]   Total Knee Arthroplasty After Failed Unicompartmental Knee Arthroplasty. Clinical Results, Radiologic Findings, and Technical Tips [J].
Borrego Paredes, Estrella ;
Barrena Sanchez, Pablo ;
Serrano Toledano, David ;
Puente Gonzalez, Andres I. ;
Fornell Perez, Salvador ;
Fernandez de Bobadilla, Gabriel Domecq .
JOURNAL OF ARTHROPLASTY, 2017, 32 (01) :193-196
[5]   Computer-assisted Revision of Failed Unicompartmental Knee Arthroplasty [J].
Confalonieri, Norberto ;
Manzotti, Alfonso ;
Chemello, Cesare ;
Cerveri, Pietro .
ORTHOPEDICS, 2010, 33 (10) :52-57
[6]   Registry outcomes of unicompartmental knee arthroplasty revisions [J].
Dudley, Thomas E. ;
Gioe, Terence J. ;
Sinner, Penny ;
Mehle, Susan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (07) :1666-1670
[7]   MRI is more accurate than CT for patient-specific total knee arthroplasty [J].
Frye, Benjamin M. ;
Najim, Amjad A. ;
Adams, Joanne B. ;
Berend, Keith R. ;
Lombardi, Adolph V., Jr. .
KNEE, 2015, 22 (06) :609-612
[8]   Rotational References for Total Knee Arthroplasty Tibial Components Change with Level of Resection [J].
Graw, Bradley P. ;
Harris, Alexander H. ;
Tripuraneni, Krishna R. ;
Giori, Nicholas J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (10) :2734-2738
[9]   Improved femoral component rotation in TKA using patient-specific instrumentation [J].
Heyse, Thomas J. ;
Tibesku, Carsten O. .
KNEE, 2014, 21 (01) :268-271
[10]   Determination of neutral tibial rotational alignment in rotating platform TKA [J].
Huddleston, JI ;
Scott, RD ;
Wiinberley, DW .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (440) :101-106