Air pollutants generated by indoor and outdoor sources adversely affect indoor air quality in many microenvironments. Exposure to indoor air pollutants such as hazardous volatile organic compounds (VOCs), particulate matter with diameters less than 2.5m (PM2.5) and 1m (PM1), and oxocarbons (e.g. CO and CO2) is of great concern to policy makers and environmental authorities due to their adverse impact on public health. Indoor air pollution from smoking tobacco using a waterpipe has been a worldwide public health challenge due to its toxic, carcinogenic and cardiovascular effects. This study investigates the release of PM2.5, PM1, CO2, CO and 72 VOCs to assess the indoor air quality during waterpipe tobacco smoking in a controlled microenvironment and a public cafe. Particulate matters, CO and CO2 were measured using an OSIRIS instrument, a 3M EVM-7, and a CO2 meter, respectively. The VOCs were sampled using pre-evacuated silicon-coated stainless-steel canisters with a 6-l capacity and analysed by an Agilent gas chromatograph with an Entech cryogen system following the US EPA Compendium Method (TO15). All measured pollutants in the controlled microenvironment showed increasing concentrations during the waterpipe smoking session with PM2.5, PM1, CO2 and total VOC contents reaching 31.4, 26.6, 142 and 38.4%, respectively, above their respective background concentrations. CO showed a build-up rate of 0.6mgm(-3)min(-1) in the controlled microenvironment, reaching 16mgm(-3) at the end of the session. In the public waterpipe cafe, the maximum hourly concentrations of PM1, PM2.5, CO and CO2 reached 27 g m(-3), 92 g m(-3), 49.5 mg m(-3) and 3244 mg m(-3), respectively. These optimum values corresponded to the number of smokers present at the cafe late at night. Overall, the public waterpipe cafe had a higher concentration of pollutants compared with the controlled microenvironment due to the number of waterpipes used in the cafe. These results will provide exciting insight into waterpipe emissions in real-world settings.
引用
收藏
页码:2849 / 2854
页数:6
相关论文
共 50 条
  • [41] Indoor air quality impacts of ventilation ducts: Ozone removal and emissions of volatile organic compounds
    Morrison, Glenn C.
    Nazaroff, William W.
    Alejandro Cano-Ruiz, J.
    Hodgson, Alfred T.
    Modera, Mark P.
    Journal of the Air and Waste Management Association, 1998, 48 (10): : 941 - 952
  • [42] A Literature Survey of Research Trends of Volatile Organic Compounds and Field Indoor Air Quality in Korea
    Sohn, Jangyeul
    Pang, Seungki
    Cho, Woojin
    Lee, Chulgoo
    MOKUZAI GAKKAISHI, 2008, 54 (05): : 245 - 254
  • [43] Impact of smoking ban at indoor public places on indoor air quality
    Bilir, Nazmi
    Ozcebe, Hilal
    TUBERKULOZ VE TORAK-TUBERCULOSIS AND THORAX, 2012, 60 (01): : 41 - 46
  • [44] VOLATILE ORGANIC-COMPOUNDS IN INDOOR AIR AND IN EXPIRED AIR AS MARKERS OF ACTIVITIES
    CAILLEUX, A
    TURCANT, A
    PREMELCABIC, A
    ALLAIN, P
    CHROMATOGRAPHIA, 1993, 37 (1-2) : 57 - 59
  • [45] Performance of air cleaners for removing multiple volatile organic compounds in indoor air
    Chen, WH
    Zhang, JSS
    Zhang, ZB
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 1101 - 1114
  • [46] Impact of material emissions and sorption of volatile organic compounds on indoor air quality in a low energy building: Field measurements and modeling
    Rizk, Malak
    Guo, Fangfang
    Verriele, Marie
    Ward, Michael
    Dusanter, Sebastien
    Blond, Nadege
    Locoge, Nadine
    Schoemaecker, Coralie
    INDOOR AIR, 2018, 28 (06) : 924 - 935
  • [47] Under glass weathering of hemp fibers reinforced polypropylene biocomposites: Impact of Volatile Organic Compounds emissions on indoor air quality
    Badji, Celia
    Beigbeder, Joana
    Garay, Helene
    Bergeret, Anne
    Benezet, Jean-Charles
    Desauziers, Valerie
    POLYMER DEGRADATION AND STABILITY, 2018, 149 : 85 - 95
  • [48] Effect of spraying air freshener on particulate and volatile organic compounds in vehicles
    Lee, Myoungho
    Lee, Soyeon
    Park, Jongmin
    Yoon, Chungsik
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 916
  • [49] Quantile regression of indoor air concentrations of volatile organic compounds (VOC)
    Schlink, Uwe
    Thiem, Alexander
    Kohajda, Tibor
    Richter, Matthias
    Strebel, Kathrin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2010, 408 (18) : 3840 - 3851
  • [50] Diffusive sampling and measurement of microbial volatile organic compounds in indoor air
    Araki, A.
    Eitaki, Y.
    Kawai, T.
    Kanazawa, A.
    Takeda, M.
    Kishi, R.
    INDOOR AIR, 2009, 19 (05) : 421 - 432