Oxides of carbon, particulate matters and volatile organic compounds impact on indoor air quality during waterpipe smoking

被引:6
|
作者
Al-Dabbous, A. N. [1 ]
Khan, A. R. [2 ]
Al-Tamimi, S. A. [1 ]
Shalash, M. [1 ]
Bajoga, A. D. [3 ]
Malek, M. J. [1 ]
机构
[1] Kuwait Inst Sci Res, Environm & Life Sci Res Ctr, Crises Decis Support Program, POB 24885, Safat 13109, Kuwait
[2] Kuwait Inst Sci Res, Environm & Life Sci Res Ctr, Environm Pollut & Climate Program, Safat, Kuwait
[3] Gombe State Univ, Dept Phys, Gombe, Nigeria
关键词
Waterpipe; Oxides of carbon; Particulate matters; Volatile organic compounds; Indoor air quality; 2ND-HAND SMOKE; PIPE SMOKING; EXPOSURE; HOOKAH; NICOTINE; MONOXIDE; SHISHA; PM2.5; POLLUTION;
D O I
10.1007/s13762-018-1870-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Air pollutants generated by indoor and outdoor sources adversely affect indoor air quality in many microenvironments. Exposure to indoor air pollutants such as hazardous volatile organic compounds (VOCs), particulate matter with diameters less than 2.5m (PM2.5) and 1m (PM1), and oxocarbons (e.g. CO and CO2) is of great concern to policy makers and environmental authorities due to their adverse impact on public health. Indoor air pollution from smoking tobacco using a waterpipe has been a worldwide public health challenge due to its toxic, carcinogenic and cardiovascular effects. This study investigates the release of PM2.5, PM1, CO2, CO and 72 VOCs to assess the indoor air quality during waterpipe tobacco smoking in a controlled microenvironment and a public cafe. Particulate matters, CO and CO2 were measured using an OSIRIS instrument, a 3M EVM-7, and a CO2 meter, respectively. The VOCs were sampled using pre-evacuated silicon-coated stainless-steel canisters with a 6-l capacity and analysed by an Agilent gas chromatograph with an Entech cryogen system following the US EPA Compendium Method (TO15). All measured pollutants in the controlled microenvironment showed increasing concentrations during the waterpipe smoking session with PM2.5, PM1, CO2 and total VOC contents reaching 31.4, 26.6, 142 and 38.4%, respectively, above their respective background concentrations. CO showed a build-up rate of 0.6mgm(-3)min(-1) in the controlled microenvironment, reaching 16mgm(-3) at the end of the session. In the public waterpipe cafe, the maximum hourly concentrations of PM1, PM2.5, CO and CO2 reached 27 g m(-3), 92 g m(-3), 49.5 mg m(-3) and 3244 mg m(-3), respectively. These optimum values corresponded to the number of smokers present at the cafe late at night. Overall, the public waterpipe cafe had a higher concentration of pollutants compared with the controlled microenvironment due to the number of waterpipes used in the cafe. These results will provide exciting insight into waterpipe emissions in real-world settings.
引用
收藏
页码:2849 / 2854
页数:6
相关论文
共 50 条
  • [1] Oxides of carbon, particulate matters and volatile organic compounds impact on indoor air quality during waterpipe smoking
    A. N. Al-Dabbous
    A. R. Khan
    S. A. Al-Tamimi
    M. Shalash
    A. D. Bajoga
    M. J. Malek
    International Journal of Environmental Science and Technology, 2019, 16 : 2849 - 2854
  • [2] Volatile organic compounds - Sources, measurements, emissions, and the impact on indoor air quality
    Wolkoff, P
    INDOOR AIR, 1995, : 1 - 73
  • [3] Diffusion and sorption of volatile organic compounds in building materials - Impact on indoor air quality
    Meininghaus, R
    Gunnarsen, L
    Knudsen, HN
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (15) : 3101 - 3108
  • [4] Diffusion and sorption of volatile organic compounds in building materials - Impact on indoor air quality
    Meininghaus, R. (roman.meininghaus@ineris.fr), 2000, American Chemical Society (34):
  • [5] Indoor air contamination during a waterpipe (narghile) smoking session
    Fromme, Hermann
    Dietrich, Silvio
    Heitmann, Dieter
    Dressel, Holger
    Diemer, Juergen
    Schulz, Thomas
    Joerres, Rudolf A.
    Berlin, Knut
    Voelkel, Wolfgang
    FOOD AND CHEMICAL TOXICOLOGY, 2009, 47 (07) : 1636 - 1641
  • [6] Carbon monoxide and volatile organic compounds as indicators of indoor air quality in underground parking facilities
    El Fadel, M
    Alameddine, I
    Kazopoulo, M
    Hamdan, M
    Nasrallah, R
    INDOOR AND BUILT ENVIRONMENT, 2001, 10 (02) : 70 - 82
  • [7] Indoor air quality in waterpipe cafes: exposure level to particulate matter
    Naddafi, Kazem
    Nabizadeh, Ramin
    Rostamy, Roohollah
    Kalan, Mohammad Ebrahimi
    Hassanvand, Mohammad Sadegh
    Fazlzadeh, Mehdi
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2019, 26 (26) : 26605 - 26616
  • [8] The use of volatile organic compounds as an indicator in indoor air quality investigations
    Popa, M
    Popa, MS
    SEVENTH INTERNATIONAL SYMPOSIUM ON LASER METROLOGY APPLIED TO SCIENCE, INDUSTRY, AND EVERYDAY LIFE, PTS 1 AND 2, 2002, 4900 : 1090 - 1093
  • [9] Total volatile organic compounds (TVOC) in indoor air quality investigations
    Molhave, L
    Clausen, G
    Berglund, B
    de Ceaurriz, J
    Kettrup, A
    Lindvall, T
    Maroni, M
    Pickering, AC
    Risse, U
    Rothweiler, H
    Seifert, B
    Younes, M
    INDOOR AIR, 1997, 7 (04) : 225 - 240
  • [10] Built environment and indoor air quality: The case of volatile organic compounds
    Kotzias, Dimitrios