Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags

被引:105
作者
Mochalski, Pawe [1 ,2 ]
King, Julian [1 ,3 ]
Unterkofler, Karl [1 ]
Amann, Anton [1 ,4 ]
机构
[1] Austrian Acad Sci, Breath Res Inst, A-6850 Dornbirn, Austria
[2] Inst Nucl Phys PAN, PL-31342 Krakow, Poland
[3] Univ Vienna, Fac Math, A-1090 Vienna, Austria
[4] Med Univ Innsbruck, Univ Clin Anesthesia, A-6020 Innsbruck, Austria
基金
奥地利科学基金会;
关键词
LUNG-CANCER; EXHALED-BREATH; ORGANIC-COMPOUNDS; ISOPRENE; SUITABILITY; LIMIT;
D O I
10.1039/c2an36193k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The stability of 41 selected breath constituents in three types of polymer sampling bags, Tedlar, Kynar, and Flexfilm, was investigated using solid phase microextraction and gas chromatography mass spectrometry. The tested molecular species belong to different chemical classes (hydrocarbons, ketones, aldehydes, aromatics, sulphurs, esters, terpenes, etc.) and exhibit close-to-breath low ppb levels (3-12 ppb) with the exception of isoprene, acetone and acetonitrile (106 ppb, 760 ppb, 42 ppb respectively). Stability tests comprised the background emission of contaminants, recovery from dry samples, recovery from humid samples (RH 80% at 37 degrees C), influence of the bag's filling degree, and reusability. Findings yield evidence of the superiority of Tedlar bags over remaining polymers in terms of background emission, species stability (up to 7 days for dry samples), and reusability. Recoveries of species under study suffered from the presence of high amounts of water (losses up to 10%). However, only heavier volatiles, with molecular masses higher than 90, exhibited more pronounced losses (20-40%). The sample size (the degree of bag filling) was found to be one of the most important factors affecting the sample integrity. To sum up, it is recommended to store breath samples in pre-conditioned Tedlar bags up to 6 hours at the maximum possible filling volume. Among the remaining films, Kynar can be considered as an alternative to Tedlar; however, higher losses of compounds should be expected even within the first hours of storage. Due to the high background emission Flexfilm is not suitable for sampling and storage of samples for analyses aiming at volatiles at a low ppb level.
引用
收藏
页码:1405 / 1418
页数:14
相关论文
共 35 条
  • [1] Amann A., 2005, Breath analysis for clinical diagnosis and therapeutic monitoring
  • [2] Amann A, 2011, EXPERT REV MOL DIAGN, V11, P207, DOI [10.1586/ERM.10.112, 10.1586/erm.10.112]
  • [3] Noninvasive detection of lung cancer by analysis of exhaled breath
    Bajtarevic, Amel
    Ager, Clemens
    Pienz, Martin
    Klieber, Martin
    Schwarz, Konrad
    Ligor, Magdalena
    Ligor, Tomasz
    Filipiak, Wojciech
    Denz, Hubert
    Fiegl, Michael
    Hilbe, Wolfgang
    Weiss, Wolfgang
    Lukas, Peter
    Jamnig, Herbert
    Hackl, Martin
    Haidenberger, Alfred
    Buszewski, Boguslaw
    Miekisch, Wolfram
    Schubert, Jochen
    Amann, Anton
    [J]. BMC CANCER, 2009, 9 : 348
  • [4] On the use of Tedlar® bags for breath-gas sampling and analysis
    Beauchamp, Jonathan
    Herbig, Jens
    Gutmann, Rene
    Hansel, Armin
    [J]. JOURNAL OF BREATH RESEARCH, 2008, 2 (04)
  • [5] Sample water removal method in volatile organic compound analysis based on diffusion through poly(vinyl fluoride) film
    Beghi, Sandra
    Guillot, Jean-Michel
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1127 (1-2) : 1 - 5
  • [6] Analysis of exhaled breath from smokers, passive smokers and non-smokers by solid-phase microextraction gas chromatography/mass spectrometry
    Buszewski, Boguslaw
    Ulanowska, Agnieszka
    Ligor, Tomasz
    Denderz, Natalia
    Amann, Anton
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (05) : 551 - 556
  • [7] Double-layer Tedlar bags: a means to limit humidity evolution of air samples and to dry humid air samples
    Cariou, S
    Guillot, JM
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (02) : 468 - 474
  • [8] A quantum chemical study of the C-C bond fission pathways of alkoxy radicals formed following OH addition to isoprene
    Dibble, TS
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 1999, 103 (42) : 8559 - 8565
  • [9] Breath ammonia and trimethylamine allow real-time monitoring of haemodialysis efficacy
    Endre, Z. H.
    Pickering, J. W.
    Storer, M. K.
    Hu, W-P
    Moorhead, K. T.
    Allardyce, R.
    McGregor, D. O.
    Scotter, J. M.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2011, 32 (01) : 115 - 130
  • [10] 3-Heptanone as a potential new marker for valproic acid therapy
    Erhart, S.
    Amann, A.
    Haberlandt, E.
    Edlinger, G.
    Schmid, A.
    Filipiak, W.
    Schwarz, K.
    Mochalski, P.
    Rostasy, K.
    Karall, D.
    Scholl-Buergi, S.
    [J]. JOURNAL OF BREATH RESEARCH, 2009, 3 (01)