摘要
Purpose: To investigate the possibility of using intensity-modulated radiotherapy (IMRT) to reduce the irradiated volumes of the normal lung and other critical structures in the treatment of non-small-cell lung cancer (NSCLC) and to investigate the effect of IMRT on the potential of spreading low doses to large volumes of normal tissues in such treatment. Methods and Materials: A retrospective treatment planning study was performed to compare IMRT and conventional three-dimensional conformal radiation therapy (3D-CRT) for 10 NSCLC patients (Stage I-IIIB). In the IMRT plans, three to nine coplanar beams were designed to treat 95% of the planning target volume with 63 Gy and to minimize the volumes of the normal lung, esophagus, heart, and spinal cord irradiated above their tolerance doses. The two types of plans were compared with respect to the planning target volume coverage, dose-volume histograms, and other dosimetric indexes of the normal structures. Results: Comparing the nine-beam IMRT plan with the 3D-CRT plan, the percentage of lung volume that received >20 Gy and the mean lung dose were reduced for all cases, with a median reduction of 8% and 2 Gy, respectively. An additional reduction of the >5-Gy volume and >10-Gy volume for the lung and thoracic tissue was more difficult with IMRT, although still possible using fewer beams in IMRT. The integral dose to the entire thorax was equivalent and even reduced for 8 of 10 cases using IMRT. Conclusion: It is possible to reduce the volumes of low doses (such as the >10-Gy volume and >20-Gy volume) for thoracic normal tissues using IMRT. The increased integral dose and low-dose volumes can be avoided for IMRT if such concerns are addressed carefully in the inverse planning process and with optimization of the IMRT beam configuration. (C) 2004 Elsevier Inc.
引用
收藏
页码:1268 / 1279
页数:12
相关论文
共 32 条
  • [1] Lung toxicity following chest irradiation in patients with lung cancer
    Abratt, RP
    Morgan, GW
    [J]. LUNG CANCER, 2002, 35 (02) : 103 - 109
  • [2] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [3] Intensity-modulated radiotherapy: Current status and issues of interest
    Boyer, AL
    Butler, EB
    DiPetrillo, TA
    Engler, MJ
    Fraass, B
    Grant, W
    Ling, CC
    Low, DA
    Mackie, TR
    Mohan, R
    Purdy, JA
    Roach, M
    Rosenman, JG
    Verhey, LJ
    Wong, JW
    Cumberlin, RL
    Stone, H
    Palta, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 880 - 914
  • [4] FITTING OF NORMAL TISSUE TOLERANCE DATA TO AN ANALYTIC-FUNCTION
    BURMAN, C
    KUTCHER, GJ
    EMAMI, B
    GOITEIN, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 123 - 135
  • [5] Response, toxicity, failure patterns, and survival in five radiation therapy oncology group (RTOG) trials of sequential and/or concurrent chemotherapy and radiotherapy for locally advanced non-small-cell carcinoma of the lung
    Byhardt, RW
    Scott, C
    Sause, WT
    Emami, B
    Komaki, R
    Fisher, B
    Lee, JS
    Lawton, C
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03): : 469 - 478
  • [6] An evaluation of two techniques for beam intensity modulation in patients irradiated for stage III non-small cell lung cancer
    de Koste, JV
    Voet, P
    Dirkx, M
    van Meerbeeck, J
    Senan, S
    [J]. LUNG CANCER, 2001, 32 (02) : 145 - 153
  • [7] Beam intensity modulation for penumbra enhancement in the treatment of lung cancer
    Dirkx, MLP
    Essers, M
    de Koste, JRV
    Senan, S
    Heijmen, BJM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 44 (02): : 449 - 454
  • [8] Goffman TE, 2002, RADIAT RES, V158, P115, DOI 10.1667/0033-7587(2002)158[0115:IMRT]2.0.CO
  • [9] 2
  • [10] Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    Graham, MV
    Purdy, JA
    Emami, B
    Harms, W
    Bosch, W
    Lockett, MA
    Perez, CA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 323 - 329