New insights into uteroplacental perfusion: Quantitative analysis using Doppler and contrast-enhanced ultrasound imaging

被引:38
|
作者
Arthuis, C. J. [1 ,2 ]
Novell, A. [1 ]
Escoffre, J. -M. [1 ]
Patat, F. [1 ,3 ]
Bouakaz, A. [1 ]
Perrotin, F. [1 ,2 ]
机构
[1] Univ Tours, UMR Inserm U 930, F-37032 Tours 1, France
[2] CHRU Tours, Dept Obstet & Gynecol, F-37044 Tours 9, France
[3] CHRU Tours, Inserm CIC IT 806, F-37044 Tours 9, France
关键词
Uteroplacental perfusion; Doppler ultrasound; Contrast-enhanced ultrasound; Placenta; Rat; UTERINE ARTERY DOPPLER; INTERVILLOUS BLOOD-FLOW; TROPHOBLAST INVASION; ABDOMINAL PREGNANCY; PREECLAMPSIA; RAT; ULTRASONOGRAPHY; MICROBUBBLES; VELOCIMETRY; AGENTS;
D O I
10.1016/j.placenta.2013.01.019
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: To monitor and quantify uteroplacental perfusion in rat pregnancies by Doppler ultrasound (DUS) and contrast-enhanced ultrasound (CEUS). Methods: Fourteen rats were randomized in two groups (the CEUS group and the control group). On days 8, 11, 14, 17, 19 and 20 of gestation, we used DUS to measure the resistance index (RI), pulsatility index and blood velocity in the uterine, arcuate and umbilical arteries in both groups. On days 14, 17 and 20, one group was also examined by CEUS. Quantitative perfusion parameters were calculated in 4 compartments (mesometrial triangle, placenta, umbilical cord and fetus) and compared. Results: The DUS measurement showed that the RI of the uterine and arcuate arteries decreased (p < 0.01) from day 14 to day 17, while velocity increased each of these arteries (p < 0.01 and p < 0.05, respectively). Quantification of uteroplacental perfusion by CEUS in bolus mode revealed that blood volume and local blood flow increased from day 14 to day 20 in the mesometrial triangle (p < 0.01) and the placenta (p < 0.05). In the CEUS destruction-replenishment mode, the perfusion parameters showed trends similar to those observed in bolus mode. No microbubbles were detected in the umbilical vein or fetal compartments. The weights of pups in the two groups did not differ significantly. Conclusions: CEUS estimates of placental perfusion complement the data provided by DUS. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 50 条
  • [21] Quantitative contrast-enhanced ultrasound imaging: a review of sources of variability
    Tang, M. -X.
    Mulvana, H.
    Gauthier, T.
    Lim, A. K. P.
    Cosgrove, D. O.
    Eckersley, R. J.
    Stride, E.
    INTERFACE FOCUS, 2011, 1 (04) : 520 - 539
  • [22] Parametric perfusion imaging with contrast-enhanced ultrasound in acute ischemic stroke
    Wiesmann, M
    Meyer, K
    Albers, T
    Seidel, G
    STROKE, 2004, 35 (02) : 508 - 513
  • [23] Contrast-enhanced ultrasound analysis of renal perfusion in normal micropigs
    Yi, Kangjae
    Ji, Seoyeoun
    Kim, Junyoung
    Yoon, Junghee
    Choi, Mincheol
    JOURNAL OF VETERINARY SCIENCE, 2012, 13 (03) : 311 - 314
  • [24] Contrast-enhanced ultrasound for molecular imaging of angiogenesis
    Eisenbrey, J. R.
    Forsberg, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S138 - S146
  • [25] Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
    Machado, Priscilla
    Tan, Allison
    Forsberg, Flemming
    Gonsalves, Carin F.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (03) : 394 - 398
  • [26] Imaging Microbubbles With Contrast-Enhanced Endobronchial Ultrasound
    Mcgrath, Sean
    Shen, Yu-Jack
    Aragaki, Masato
    Motooka, Yamato
    Koga, Takamasa
    Gregor, Alexander
    Bernards, Nicholas
    Cherin, Emmanuel
    Demore, Christine E. M.
    Yasufuku, Kazuhiro
    Matsuura, Naomi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2024, 50 (01) : 28 - 38
  • [27] Quantitative analysis of tissue perfusion using contrast-enhanced transabdominal ultrasound (CEUS) in the evaluation of the severity of acute pancreatitis
    Golea, Adela
    Badea, Radu
    Socaciu, Mihai
    Diaconu, Brindusa
    Iacob, Daniela
    MEDICAL ULTRASONOGRAPHY, 2010, 12 (03) : 198 - 204
  • [28] Quantitative Perfusion Analysis of Malignant Liver Tumors Dynamic Computed Tomography and Contrast-Enhanced Ultrasound
    Goetti, Robert
    Reiner, Caecilia S.
    Knuth, Alexander
    Klotz, Ernst
    Stenner, Frank
    Samaras, Panagiotis
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2012, 47 (01) : 18 - 24
  • [29] Contrast-enhanced ultrasound imaging for intestinal lymphoma
    Cui, Ning-Yi
    Gong, Xuan-Tong
    Tian, Yan-Tao
    Wang, Yong
    Zhang, Rui
    Liu, Meng-Jia
    Han, Jie
    Wang, Bo
    Yang, Di
    WORLD JOURNAL OF GASTROENTEROLOGY, 2021, 27 (32) : 5438 - 5447
  • [30] International guidelines for contrast-enhanced ultrasonography: ultrasound imaging in the new millennium
    Nolsoe, Christian Pallson
    Lorentzen, Torben
    ULTRASONOGRAPHY, 2016, 35 (02) : 89 - 103