Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype

被引:0
|
作者
Ghani, Muhammad U. [1 ]
Wu, Di [1 ]
Li, Yuhua [1 ]
Kang, Minhua [1 ]
Chen, Wei R.
Wu, Xizeng
Liu, Hong [1 ]
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
来源
BIOPHOTONICS AND IMMUNE RESPONSES VIII | 2013年 / 8582卷
关键词
Contrast to Noise Ratio; Phase Contrast; RADIOGRAPHY; RESOLUTION;
D O I
10.1117/12.2001525
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study was to determine the Contrast to Noise Ratio (CNR) of the x-ray images taken with the phase contrast imaging mode and compare them with the CNR of the images taken under the conventional mode. For each mode, three images were taken under three exposure conditions of 100 kVp (2.8mAs), 120 kVp (1.9mAs) and 140kVp (1.42mAs). A 1.61cm thick contrast detail phantom was used as an imaging object. For phase contrast, the source to image detector distance (SID) was 182.88 cm and the source to object (SOD) distance was 73.15 cm. The SOD was the same as SID in the conventional imaging mode. A computed radiography (CR) plate was used as a detector and the output CR images were converted to linear form in relation with the incident x-ray exposure. To calculate CNR, an image processing software was used to determine the mean pixel value and the standard deviation of the pixels in the region of interest (ROI) and in the nearby background around ROI. At any given exposure condition investigated in this study, the CNR values for the phase contrast images were better as compared to the corresponding conventional mode images. The superior image quality in terms of CNR is contributed by the phase-shifts resulted contrast, as well as the reduced scatters due to the air gap between the object and the detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Nanoscale quantitative phase imaging using XOR-based X-ray differential interference contrast microscopy
    Nakamura, Takashi
    Chang, Chang
    ULTRAMICROSCOPY, 2012, 113 : 139 - 144
  • [42] Quantitative X-ray projection microscopy: phase-contrast and multi-spectral imaging
    Mayo, SC
    Miller, PR
    Wilkins, SW
    Davis, TJ
    Gao, D
    Gureyev, TE
    Paganin, D
    Parry, DJ
    Pogany, A
    Stevenson, AW
    JOURNAL OF MICROSCOPY-OXFORD, 2002, 207 : 79 - 96
  • [43] A theoretical framework for comparing noise characteristics of spectral, differential phase-contrast and spectral differential phase-contrast x-ray imaging
    Mechlem, Korbinian
    Sellerer, Thorsten
    Viermetz, Manuel
    Herzen, Julia
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (06)
  • [44] X-ray phase contrast angiography using CO2 as contrast agent
    Lundstrom, Ulf
    Larsson, Daniel H.
    Takman, Per A. C.
    Scott, Lena
    Burvall, Anna
    Hertz, Hans M.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [45] Simulation of X-ray Phase-contrast Imaging Using Grating-interferometry
    Bartl, P.
    Durst, J.
    Haas, W.
    Michel, T.
    Ritter, A.
    Weber, T.
    Anton, G.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3577 - 3580
  • [46] Preliminary research on body composition measurement using X-ray phase contrast imaging
    Han, Huajie
    Sharma, Yash
    Zan, Guibin
    Wu, Zhao
    Wang, Shenghao
    Wu, Yanlin
    Momose, Atsushi
    Zhai, Chao
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 : 1 - 8
  • [47] Contrast transfer function in grating-based x-ray phase-contrast imaging
    Huang, Jianheng
    Du, Yang
    Lin, Danying
    Liu, Xin
    Niu, Hanben
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 747 : 13 - 18
  • [48] X-ray phase contrast imaging using a micro-focused electron source
    Chang Shengcheng
    Zhu Zhuoya
    Lei Wei
    Zhang Xiaobing
    Li Yuan
    Yang Hua
    2016 29TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2016,
  • [49] Fast X-Ray Phase-Contrast Imaging Using High Resolution Detector
    Wang, Zhentian
    Huang, Zhifeng
    Zhang, Li
    Kang, Kejun
    Zhu, Peiping
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 1383 - 1388
  • [50] Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner
    Mueller, Mark
    Yaroshenko, Andre
    Velroyen, Astrid
    Bech, Martin
    Tapfer, Arne
    Pauwels, Bart
    Bruyndonckx, Peter
    Sasov, Alexander
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12)