Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype

被引:0
|
作者
Ghani, Muhammad U. [1 ]
Wu, Di [1 ]
Li, Yuhua [1 ]
Kang, Minhua [1 ]
Chen, Wei R.
Wu, Xizeng
Liu, Hong [1 ]
机构
[1] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
来源
BIOPHOTONICS AND IMMUNE RESPONSES VIII | 2013年 / 8582卷
关键词
Contrast to Noise Ratio; Phase Contrast; RADIOGRAPHY; RESOLUTION;
D O I
10.1117/12.2001525
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The purpose of this study was to determine the Contrast to Noise Ratio (CNR) of the x-ray images taken with the phase contrast imaging mode and compare them with the CNR of the images taken under the conventional mode. For each mode, three images were taken under three exposure conditions of 100 kVp (2.8mAs), 120 kVp (1.9mAs) and 140kVp (1.42mAs). A 1.61cm thick contrast detail phantom was used as an imaging object. For phase contrast, the source to image detector distance (SID) was 182.88 cm and the source to object (SOD) distance was 73.15 cm. The SOD was the same as SID in the conventional imaging mode. A computed radiography (CR) plate was used as a detector and the output CR images were converted to linear form in relation with the incident x-ray exposure. To calculate CNR, an image processing software was used to determine the mean pixel value and the standard deviation of the pixels in the region of interest (ROI) and in the nearby background around ROI. At any given exposure condition investigated in this study, the CNR values for the phase contrast images were better as compared to the corresponding conventional mode images. The superior image quality in terms of CNR is contributed by the phase-shifts resulted contrast, as well as the reduced scatters due to the air gap between the object and the detector.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Benchtop phase-contrast X-ray imaging
    Gundogdu, O.
    Nirgianaki, E.
    Ismail, E. Che
    Jenneson, P. M.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (12) : 1337 - 1344
  • [22] X-ray phase contrast imaging of spherical capsules
    Fourmaux, S.
    Hallin, E.
    Krol, A.
    Bourgade, J-L
    Kieffer, J-C
    OPTICS EXPRESS, 2020, 28 (09) : 13978 - 13990
  • [23] Edge-illumination x-ray phase-contrast imaging
    Olivo, Alessandro
    JOURNAL OF PHYSICS-CONDENSED MATTER, 2021, 33 (36)
  • [24] X-ray Phase Contrast Allows Three Dimensional, Quantitative Imaging of Hydrogel Implants
    Appel, Alyssa A.
    Larson, Jeffery C.
    Jiang, Bin
    Zhong, Zhong
    Anastasio, Mark A.
    Brey, Eric M.
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (03) : 773 - 781
  • [25] Project for applications of phase-contrast X-ray imaging to medicine using an X-ray interferometer
    Momose, A
    Yoneyama, A
    Takeda, T
    Itai, Y
    Tu, J
    Hirano, K
    MEDICAL APPLICATIONS OF PENETRATING RADIATION, 1999, 3770 : 23 - 31
  • [26] In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science
    Mayo, Sheridan C.
    Stevenson, Andrew W.
    Wilkins, Stephen W.
    MATERIALS, 2012, 5 (05) : 937 - 965
  • [27] Hard X-ray quantitative non-interferometric phase-contrast imaging
    Gureyev, TE
    Raven, C
    Snigirev, A
    Snigireva, I
    Wilkins, SW
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 356 - 364
  • [28] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971)
  • [29] Propagation-based x-ray phase contrast imaging using an iterative phase diversity technique
    Carroll, Aidan J.
    van Riessen, Grant A.
    Balaur, Eugeniu
    Dolbnya, Igor P.
    Tran, Giang N.
    Peele, Andrew G.
    JOURNAL OF OPTICS, 2018, 20 (03)
  • [30] An Analytic Method of Phase Retrieval for X-Ray Phase Contrast Imaging
    Palamodov, Victor
    JOURNAL OF FOURIER ANALYSIS AND APPLICATIONS, 2020, 26 (06)