DOSIMETRIC EVALUATION OF A NEWLY DEVELOPED RADIOCHROMIC FILM FOR RADIATION PROCESSING

被引:0
作者
Akhavan, A. [1 ]
Sohrabpour, M. [2 ]
Sharifzadeh, M. [1 ]
机构
[1] Radiat Applicat Res Sch, Nucl Sci & Technol Res Inst, Tehran, Iran
[2] Sharif Univ Technol, Dept Energy Engn, Tehran, Iran
来源
IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY TRANSACTION A-SCIENCE | 2007年 / 31卷 / A4期
关键词
Dosimetry; film dosimeter; radiochromic film; gamma radiation; electron beam;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In order to improve the performance of a newly developed radiochromic film, GIC-79, some dosimetric characteristics of this film have been Studied based oil relevant standard practice. The present study describes some parameters that may affect the dosimeter response before, during, and after irradiation. The effect of absorbed dose rate on dosimeter response was determined by irradiating dosimeters at low absorbed dose rates with gamma rays. Calibration irradiations of dosimeters were performed with both gamma rays and also electrons to determine the effect of large difference absorbed dose rates on dosimeter response. In addition, post irradiation stability was obtained and also the temperature and humidity effects on the dosimeter response during the storage time prior to irradiation and post irradiation have been investigated.
引用
收藏
页码:397 / 401
页数:5
相关论文
共 50 条
  • [1] Dosimetric evaluation of methyl red radiochromic film for radiation processing
    Al Zahrany, Awad
    Rabaeh, Khalid
    Eyadeh, Molham
    Basfar, Ahmed
    PIGMENT & RESIN TECHNOLOGY, 2021, 50 (02) : 157 - 162
  • [2] Study on radiochromic film by batch production for radiation processing
    Chen Y.-Z.
    Chen K.-S.
    Zhang W.-D.
    Li M.
    Ye H.-S.
    Lin M.
    Xu L.-J.
    Xia W.
    Cui Y.
    Luo R.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2016, 50 (09): : 1680 - 1687
  • [3] Dosimetric characteristics of an improved radiochromic film
    Meigooni, AS
    Sanders, MF
    Ibbott, GS
    Szeglin, SR
    MEDICAL PHYSICS, 1996, 23 (11) : 1883 - 1888
  • [4] Evaluation of dosimetric functions for Ir-192 source using radiochromic film
    Sellakumar, P.
    Kumar, A. Sathish
    Supe, Sanjay S.
    Anand, M. R.
    Nithya, K.
    Sajitha, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (10) : 1862 - 1866
  • [5] Radiochromic film dosimeter based on povidone-iodine for gamma dosimetric applications
    El-Shawadfy, El-Saeid R.
    Gafar, Sameh M.
    JOURNAL OF POLYMER ENGINEERING, 2025, 45 (04) : 344 - 350
  • [6] Radiochromic film for medical radiation dosimetry
    Butson, MJ
    Yu, PKN
    Cheung, T
    Metcalfe, P
    MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) : 61 - 120
  • [7] Study of the characteristics of a radiochromic film for dosimetry of small radiation beams
    Caporali, C
    Guerra, AS
    Laitano, RF
    Pimpinella, M
    Possenti, L
    PHYSICA MEDICA, 1997, 13 : 87 - 89
  • [8] Comparison of Epson scanner quality for radiochromic film evaluation
    Alnawaf, Hani
    Yu, Peter K. N.
    Butson, Martin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (05): : 314 - 321
  • [9] Dosimetric evaluation of an indigenously developed 10 MeV industrial electron beam irradiator
    Chilkulwar, R. H.
    Sharma, S. D.
    Chaudhary, N.
    Acharya, S.
    Mayya, Y. S.
    Mittal, K. C.
    Gantayet, L. M.
    RADIATION MEASUREMENTS, 2012, 47 (08) : 628 - 633
  • [10] Absorption spectra response of XRQA radiochromic film to x-ray radiation
    Alnawaf, Hani
    Cheung, Tsang
    Butson, Martin J.
    Yu, Peter K. N.
    RADIATION MEASUREMENTS, 2010, 45 (01) : 129 - 132