Capabilities and limitations of direct analysis in real time orbitrap mass spectrometry and tandem mass spectrometry for the analysis of synthetic and natural polymers

被引:31
|
作者
Bridoux, Maxime C. [1 ]
Machuron-Mandard, Xavier [1 ]
机构
[1] CEA, DAM, DIF, F-91297 Arpajon, France
关键词
ASSISTED-LASER-DESORPTION/IONIZATION; LONG-CHAIN POLYAMINES; COLLISION-INDUCED DISSOCIATION; ELECTROSPRAY-IONIZATION; GAS-PHASE; DIATOM BIOSILICA; POLY(ALKYL METHACRYLATE)S; FRAGMENTATION PATHWAYS; CHEMICAL-IONIZATION; ION-SOURCE;
D O I
10.1002/rcm.6664
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: Despite the widespread use of direct analysis in real time mass spectrometry (DART-MS), its capabilities in terms of accessible mass range and the types of polymers that can be analysed are not well known. The goal of this work was to evaluate the capabilities and limitations of this ionization technique combined with orbitrap mass spectrometry and tandem mass spectrometry, for the characterization (structural and polydispersity metrics) of various synthetic and natural polymers. METHODS: The capabilities and limitations of DART-MS (and -MS2), using an orbitrap mass spectrometer, for polymer analysis were evaluated using various industrial synthetic polymers and biopolymers. Stainless steel mesh screens secured on a movable rail were used as the sampling surface, onto which 5 of various polymers dissolved in tetrahydrofuran were added. Assignment of spectral features and calculation of molecular weight and polydispersity metrics were performed using Polymerix T software and the results were compared with those obtained by gel-permeation chromatography (GPC). RESULTS: Protonated oligomers and ammonium adducts were instantaneously detected as the major ionisation products in positive ion mode. Only perfluoropolyethers (PFPEs) were ionised in negative mode and detected as [M]-. ions. Only singly charged molecular species were observed for all oligomers under study, allowing for a rapid determination of the molecular weight and polydispersity metrics of polymers. At elevated DART gas temperatures (400-500 degrees C) the molecular weight and polydispersity metrics compared fairly well with those obtained by GPC, with polymers whose masses ranged from 200 g. mol-1 to 4000 g. mol(-1). CONCLUSIONS: DART-MS allowed the direct and rapid analysis (mass spectra and tandem mass spectra of all the polymers were acquired in seconds) based on the exact masses of their [M+H](+) and [M+NH4](+) ions (in the positive mode) or [M](-). ions (for polymers having a high sensitivity toward electron-capture ionisation such as PFPEs), as well as the exact masses of their product ions, for both synthetic and natural polymers under ambient conditions without any sample pre-treatment. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:2057 / 2070
页数:14
相关论文
共 50 条
  • [31] Sensitivity "Hot Spots" in the Direct Analysis in Real Time Mass Spectrometry of Nerve Agent Simulants
    Harris, Glenn A.
    Falcone, Caitlin E.
    Fernandez, Facundo M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (01) : 153 - 161
  • [32] Direct analysis real-time-high-resolution mass spectrometry for Triticum species authentication
    Miano, Brunella
    Righetti, Laura
    Piro, Roberto
    Dall'Asta, Chiara
    Folloni, Silvia
    Galaverna, Gianni
    Suman, Michele
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2018, 35 (12): : 2291 - 2297
  • [33] Unraveling the architecture of plasma polymers by electrospray tandem mass spectrometry
    Fouquet, Thierry
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 389 : 1 - 9
  • [34] Direct analysis of complex mixtures by mass spectrometry
    Cooks, R. Graham
    Jarmusch, Alan K.
    Wleklinski, Michael
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 377 : 709 - 718
  • [35] Detection of Saponins and Oligosaccharides in Herbs Using Direct Analysis in Real-time Mass Spectrometry
    He Yangfang
    Liu Wenlong
    Su Rui
    Xiu Yang
    Pei Jin
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2017, 33 (02) : 172 - 178
  • [36] Chemometric brand differentiation of commercial spices using direct analysis in real time mass spectrometry
    Pavlovich, Matthew J.
    Dunn, Emily E.
    Hall, Adam B.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (09) : 1123 - 1130
  • [37] Versatility of tandem mass spectrometry for focused analysis of oxylipids
    Petta, Tania
    Moraes, Luiz A. B.
    Faccioli, Lucia H.
    JOURNAL OF MASS SPECTROMETRY, 2015, 50 (07): : 879 - 890
  • [38] Argon Direct Analysis in Real Time Mass Spectrometry in Conjunction with Makeup Solvents: A Method for Analysis of Labile Compounds
    Yang, Hongmei
    Wan, Debin
    Song, Fengrui
    Liu, Zhiqiang
    Liu, Shuying
    ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1305 - 1309
  • [39] Analysis of isoaspartate in peptides by electrospray tandem mass spectrometry
    Lehmann, WD
    Schlosser, A
    Erben, G
    Pipkorn, R
    Bossemeyer, D
    Kinzel, V
    PROTEIN SCIENCE, 2000, 9 (11) : 2260 - 2268
  • [40] Phosphorothioate RNA Analysis by NETD Tandem Mass Spectrometry
    Peters-Clarke, Trenton M.
    Quan, Qiuwen
    Anderson, Benton J.
    McGee, William M.
    Lohr, Emily
    Hebert, Alexander S.
    Westphall, Michael S.
    Coon, Joshua J.
    MOLECULAR & CELLULAR PROTEOMICS, 2024, 23 (04)