VOLTAMMETRIC DETERMINATION OF ANTI-MALARIAL DRUG AMODIAQUINE AT A BORON-DOPED DIAMOND ELECTRODE SURFACE IN AN ANIONIC SURFACTANT MEDIA

被引:3
|
作者
Kamal, Sara Kurdo [1 ]
Yardim, Yavuz [1 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey
关键词
amodiaquine; antimalarial drug; surfactant; boron-doped diamond electrode; voltammetry; PERFORMANCE LIQUID-CHROMATOGRAPHY; RECENT ACHIEVEMENTS; HUMAN PLASMA; ELECTROCHEMISTRY; ARTESUNATE; COMBINATION; METABOLITES; MALARIA;
D O I
10.20450/mjcce.2022.2565
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, the electrochemical determination of the amodiaquine (ADQ) drug was evaluated us-ing an electrochemically pretreated boron-doped diamond (BDD) electrode due to the enhanced surface activity. The cyclic voltammogram results of ADQ were given as single reversible and diffusion-controlled peaks at +0.48 V for the oxidation peak and +0.05 V for the reduction peak (vs. Ag/AgCl) in Britton-Robinson (BR) buffer at pH 8.0. The peak potential and current signals of ADQ were evaluated at the surface of the BDD electrode using instrumental parameters to develop a simple method for ADQ de-tection. Also, the effect of an anionic surfactant, sodium dodecyl sulfate (SDS), on the adsorption ap-plicability of the BDD electrode significantly increased the stripping voltammetric determination of ADQ. Under the optimal conditions chosen and employing square-wave adsorptive stripping voltamme-try at the BDD electrode, ADQ was determined at + 0.34 V (vs. Ag/AgCl) at the open-circuit condition in BR buffer at pH 8.0 in the presence of 2 center dot 10-4 mol l-1 SDS. Furthermore, analytical parameters showed the linear relationship for ADQ determination in the concentration range of 0.1-20.0 mu g ml-1 (2.2 center dot 10-7 - 4.3 center dot 10-5 mol l-1), with a detection limit of 0.03 mu g ml-1 (6.5 center dot 10-8 mol l-1). The proposed approach can be applied to determine ADQ in water samples.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 50 条
  • [31] Electroanalytical determination of enrofloxacin based on the enhancement effect of the anionic surfactant at anodically pretreated boron-doped diamond electrode
    Donmez, Fatih
    Yardim, Yavuz
    Senturk, Zuhre
    DIAMOND AND RELATED MATERIALS, 2018, 84 : 95 - 102
  • [32] Evaluation of boron-doped diamond electrode for simultaneous voltammetric determination of hydrochlorothiazide and losartan in pharmaceutical formulations
    Gardenal Santos, Michely Cristina
    Teixeira Tarley, Cesar Ricardo
    Dall'Antonia, Luiz Henrique
    Sartori, Elen Romao
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 263 - 270
  • [33] Sensitive and selective voltammetric method for determination of quinoline alkaloid, quinine in soft drinks and urine by applying a boron-doped diamond electrode
    Dushna, Olha
    Dubenska, Liliya
    Marton, Marian
    Hatala, Michal
    Vojs, Marian
    MICROCHEMICAL JOURNAL, 2023, 191
  • [34] Sensing of the COVID-19 antiviral molnupiravir in the presence of an anionic surfactant on the surface of a boron-doped diamond electrode in pharmaceutical formulation
    Bedir, Yunus
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2025, 156 (02): : 145 - 154
  • [35] VOLTAMMETRIC QUANTIFICATION OF A NONSTEROIDAL ANTI-INFLAMMATORY AGENT DIFLUNISAL BASED ON THE ENHANCEMENT EFFECT OF CATIONIC SURFACTANT ON BORON-DOPED DIAMOND ELECTRODE
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Alali, Amer
    Yardim, Yavuz
    MACEDONIAN JOURNAL OF CHEMISTRY AND CHEMICAL ENGINEERING, 2021, 40 (01) : 11 - 20
  • [36] Voltammetric determination of plant hormone indole-3-butyric acid in acidic media employing boron-doped diamond electrode
    Chylkova, Jaromira
    Janikova, Lenka
    Sedlak, Milos
    Vana, Jiri
    Selesovska, Renata
    MONATSHEFTE FUR CHEMIE, 2019, 150 (03): : 443 - 449
  • [37] Simultaneous voltammetric determination of phenolic antioxidants in food using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    FOOD CHEMISTRY, 2010, 123 (03) : 886 - 891
  • [38] Voltammetric determination of plant hormone indole-3-butyric acid in acidic media employing boron-doped diamond electrode
    Jaromíra Chýlková
    Lenka Janíková
    Miloš Sedlák
    Jiří Váňa
    Renáta Šelešovská
    Monatshefte für Chemie - Chemical Monthly, 2019, 150 : 443 - 449
  • [39] Boron-doped Diamond Electrodes for Voltammetric Determination of Benzophenone-3
    Zavazalova, Jaroslava
    Prochazkova, Katerina
    Schwarzova-Peckova, Karolina
    ANALYTICAL LETTERS, 2016, 49 (01) : 80 - 91
  • [40] Voltammetric determination of sodium cyclamate in dietary products using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2008, 31 (06): : 1405 - 1409