Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study

被引:66
|
作者
Tao, Baoxin [1 ]
Feng, Yuan [2 ]
Fan, Xingqi [3 ]
Zhuang, Minjie [1 ]
Chen, Xiaojun [3 ]
Wang, Feng [4 ]
Wu, Yiqun [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Stomatol,Sch Med,Shanghai Key Lab Stomatol,S, Chinese Acad Med Sci,Res Unit Oral & Maxillofacia, Natl Ctr Stomatol,Natl Clin Res Ctr Oral Dis,Dept, 280 Mohe Rd, Shanghai, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Mech Engn, Dongchuan Rd 800, Shanghai 200240, Peoples R China
[3] Shanghai Jiao Tong Univ, Inst Biomed Mfg & Life Qual Engn, Sch Mech Engn, State Key Lab Mech Syst & Vibrat, Room 805,Dongchuan Rd 800, Shanghai 200240, Peoples R China
[4] Shanghai Jiao Tong Univ, Dept Oral Implantol,Sch Med,Res Unit Oral & Maxil, Chinese Acad Med Sci,Shanghai Key Lab Stomatol,Sh, Coll Stomatol,Natl Ctr Stomatol,Natl Clin Res Ctr, 639 Zhizaoju Rd, Shanghai, Peoples R China
关键词
Accuracy; Computer-assisted surgery; Robot-assisted surgery; Phantom study; CURRENT STATE; PLACEMENT; METAANALYSIS; GUIDE;
D O I
10.1016/j.jdent.2022.104170
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To compare the accuracy of dental implant placement using a dynamic navigation and a robotic system. Methods: Eighty three-dimensional (3D) printed phantoms, including edentulous and partially edentulous jaws, were assigned to two groups: a dynamic navigation system (Beidou-SNS) group and a robotic system (Hybrid Robotic System for Dental Implant Surgery, HRS-DIS) group. The entry, exit and angle deviations of the implants in 3D world were measured after pre-operative plans and postoperative cone-beam computed tomography (CBCT) fusion. A linear mixed model with a random intercept was applied, and a p value <.05 was considered statistically significant. Results: A total of 480 implants were placed in 80 phantoms. The comparison deviation of the dynamic navigation system and robotic system groups showed a mean (+/- SD) entry deviation of 0.96 +/- 0.57 mm vs. 0.83 +/- 0.55 mm (p=0.04), a mean exit deviation of 1.06 +/- 0.59 mm vs. 0.91 +/- 0.56 mm (p=0.04), and a mean angle deviation of 2.41 +/- 1.42 degrees vs. 1 +/- 0.48 degrees (p<0.00). Conclusions: The implant positioning accuracy of the robotic system was superior to that of the dynamic navigation system, suggesting that this prototype robotic system (HRS-DIS) could be a promising tool in dental implant surgery.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 149
  • [32] Verification of the usability of a navigation method in dental implant surgery: In vitro comparison with the stereolithographic surgical guide template method
    Kang, Sang-Hoon
    Lee, Jae-Won
    Lim, Se-Ho
    Kim, Yeon-Ho
    Kim, Moon-Key
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (07) : 1530 - 1535
  • [33] Accuracy of a Novel Robot-Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study
    Chen, Jianping
    Ding, Yude
    Cao, Ruijue
    Zheng, Yuchen
    Shen, Liheng
    Wang, Linhong
    Yang, Fan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [34] Effect of implant shape and length on the accuracy of robot-assisted immediate implant surgery: An in vitro study
    Wang, Yunxiao
    Yu, Shimin
    Wang, Yulan
    Feng, Yi
    Yan, Qi
    Zhang, Yufeng
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (03) : 350 - 357
  • [35] Accuracy of Dynamic Navigation for Dental Implant Placement-Model-Based Evaluation
    Emery, Robert W.
    Merritt, Scott A.
    Lank, Kathryn
    Gibbs, Jason D.
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (05) : 399 - 405
  • [36] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Dong Wu
    Lin Zhou
    Jin Yang
    Bao Zhang
    Yanjun Lin
    Jiang Chen
    Wenxiu Huang
    Yonghui Chen
    International Journal of Implant Dentistry, 6
  • [37] Accuracy of dynamic navigation compared to static surgical guide for dental implant placement
    Wu, Dong
    Zhou, Lin
    Yang, Jin
    Zhang, Bao
    Lin, Yanjun
    Chen, Jiang
    Huang, Wenxiu
    Chen, Yonghui
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [38] Accuracy of haptic robotic guidance of dental implant surgery for completely edentulous arches
    Bolding, Scotty L.
    Reebye, Uday N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) : 639 - 647
  • [39] Learning curve of dynamic navigation-assisted zygomatic implant surgery: An in vitro study
    Wang, Wenying
    Zhuang, Minjie
    Tao, Baoxin
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (01) : 178e1 - 178e12
  • [40] The effect of implant surgery experience on the learning curve of a dynamic navigation system: an in vitro study
    Zonghe Xu
    Lin Zhou
    Ming Zheng
    Yanjun Lin
    Wenxiu Huang
    Jiang Chen
    Yan Li
    Dong Wu
    BMC Oral Health, 23