Low-Temperature Plasma Probe Mass Spectrometry for Analytes Separated on Thin-Layer Chromatography Plates: Direct vs Laser Assisted Desorption

被引:17
|
作者
Gong, Xiaoxia [1 ]
Zhang, Dong [1 ]
Embile, Inah B. [1 ]
She, Yue [1 ]
Shi, Songyue [1 ]
Gamez, Gerardo [1 ]
机构
[1] Texas Tech Univ, Dept Chem & Biochem, Lubbock, TX 79409 USA
关键词
AMBIENT IONIZATION; VALPROIC ACID; AMINO-ACID; ELECTROSPRAY-IONIZATION; HEPATOTOXICITY; ABLATION; TOOL; TLC;
D O I
10.1021/jasms.0c00246
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Thin-layer chromatography (TLC) is a widespread technique because it allows fast, simple, and inexpensive analyte separations. In addition, direct analysis of the compounds separated on TLC plates via mass spectrometry (MS) has been shown to provide high sensitivity and selectivity while avoiding time-consuming sample extraction protocols. Here, direct desorption low-temperature plasma-mass spectrometry (LTP-MS) as well as diode laser assisted desorption (LD) LTP-MS are studied for direct spatially resolved analysis of compounds from TLC plates. Qualitative and quantitative characterization of amino acids, pharmaceuticals, and structural isomers were performed. The nature of the TLC plate stationary phase was found to have a significant influence, together with the analyte's characteristics, on the desorption efficiency. Tandem MS is shown to greatly improve the limits of detection (LODs). Direct desorption LTP-MS, without external thermal assisted desorption, demonstrates its best performance with cellulose TLC plates (LODs, 0.01 ng/mm(2) to 2.55 ng/mm(2)) and restricted performance with normal-phase (NP) TLC plates (several analytes without observable signal). LD LTP-MS, with systematic optimization of irradiance and focal point diameter, is shown to overcome the direct-desorption limitations and reach significantly improved LODs with NP TLC plates (up to x 1000 better). In addition, a wide-ranging characterization of amino acid analytical figures of merit with LD LTP-MS shows that LODs from 84 pg/mm(2) down to 0.3 pg/mm(2) are achieved on NP TLC plates.
引用
收藏
页码:1981 / 1993
页数:13
相关论文
共 38 条
  • [21] Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper
    Bouza, Marcos
    Ahlmann, Norman
    Garcia-Reyes, Juan F.
    Franzke, Joachim
    ANALYTICAL CHEMISTRY, 2023, 95 (50) : 18370 - 18378
  • [22] Rapid screening of active ingredients in drugs by mass spectrometry with low-temperature plasma probe
    Yueying Liu
    Ziqing Lin
    Sichun Zhang
    Chengdui Yang
    Xinrong Zhang
    Analytical and Bioanalytical Chemistry, 2009, 395 : 591 - 599
  • [23] Speciation of Metals in Asphaltenes by High-Performance Thin-Layer Chromatography and Laser Ablation Inductively Coupled Plasma-Mass Spectrometry
    Moulian, Remi
    Sama, Sara Gutierrez
    Garnier, Carole
    Mounicou, Sandra
    Enrico, Maxime
    Jaurand, Xavier
    Lobinski, Ryszard
    Giusti, Pierre
    Bouyssiere, Brice
    Barrere-Mangote, Caroline
    ENERGY & FUELS, 2019, 33 (07) : 6060 - 6068
  • [24] Post-chromatographic fixed-charge derivatization for the analysis of hydroxyl-containing compounds by a combination of thin-layer chromatography and matrix-assisted laser desorption/ionization mass spectrometry
    Esparza, Cesar
    Borisov, R. S.
    Polovkov, N. Yu
    Zaikin, V. G.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1560 : 97 - 103
  • [25] Differently complex oligosaccharides can be easily identified by matrix-assisted laser desorption and ionization time-of-flight mass spectrometry directly from a standard thin-layer chromatography plate
    Nimptsch, K.
    Suess, R.
    Riemer, T.
    Nimptsch, A.
    Schnabelrauch, M.
    Schiller, J.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (23) : 3711 - 3715
  • [26] A direct and simple method of coupling matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) to thin-layer chromatography (TLC) for the analysis of phospholipids from egg yolk
    Beate Fuchs
    Jürgen Schiller
    Rosmarie Süß
    Martin Schürenberg
    Detlev Suckau
    Analytical and Bioanalytical Chemistry, 2007, 389 : 827 - 834
  • [27] A direct and simple method of coupling matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) to thin-layer chromatography (TLC) for the analysis of phospholipids from egg yolk
    Fuchs, Beate
    Schiller, Juergen
    Suess, Rosmarie
    Schuerenberg, Martin
    Suckau, Detlev
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (03) : 827 - 834
  • [28] Thin-layer chromatography combined with diode laser thermal vaporization inductively coupled plasma mass spectrometry for the determination of selenomethionine and selenocysteine in algae and yeast
    Bednarik, Antonin
    Kuta, Jan
    Vu, Dai Long
    Ranglova, Karolina
    Hrouzek, Pavel
    Kanicky, Viktor
    Preisler, Jan
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1533 : 199 - 207
  • [29] Detection of layer-by-layer self-assembly multilayer films by low-temperature plasma mass spectrometry
    Xu, Xiangyu
    Na, Na
    Wen, Jiying
    Ouyang, Jin
    JOURNAL OF MASS SPECTROMETRY, 2013, 48 (02): : 172 - 178
  • [30] Separation and detection of apricot leaf triterpenes by high-performance thin-layer chromatography combined with direct bioautography and mass spectrometry
    Moricz, Agnes M.
    Ott, Peter G.
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1675