Creatinine-induced specific signal responses and enzymeless ratiometric electrochemical detection based on copper nanoparticles electrodeposited on reduced graphene oxide-based hybrids

被引:77
作者
Gao, Xiaohui [1 ]
Gui, Rijun [1 ]
Guo, Huijun [1 ]
Wang, Zonghua [1 ]
Liu, Qingyun [2 ]
机构
[1] Qingdao Univ, Coll Chem & Chem Engn, Shandong Sino Japanese Ctr Collaborat Res Carbon, Qingdao 266071, Peoples R China
[2] Shandong Univ Sci & Technol, Coll Chem & Environm Engn, Qingdao 266590, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2019年 / 285卷
基金
中国国家自然科学基金;
关键词
Ratiometric; Electrochemical sensors; Copper nanoparticles; Graphene oxide; Creatinine; URIC-ACID; BARE ELECTRODE; BIOSENSOR; FABRICATION; SERUM; RECOGNITION; PLATFORM; COMPLEX; SENSORS; ASSAY;
D O I
10.1016/j.snb.2019.01.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this article, a novel and efficient electrochemical sensor of creatinine was facilely constructed on the surface of multifunctional nanohybrids-modified glassy carbon electrode (GCE), integrating creatinine-induced specific signal response and enzymeless ratiometric signal detection strategy. Dopamine hydrochloride as a reducing agent was dispersed in interface layers of graphene oxide. One-step hydrothermal reaction of graphene oxide with dopamine hydrochloride was conducted to prepare reduced graphene oxide (rGO), together with self-polymerization of polydopamine (PDA) attaching on rGO. Nile blue (NB) was loaded on rGO under ultra-sonication through pi-pi stacking interactions between rGO and NB. The resulting PDA-rGO-NB complex was drop-coated on the surface of GCE. Under cyclic voltammetry scanning, copper nanoparticles (CuNPs) were prepared through electrochemical reduction of Cu2+ ions and electrodeposited on PDA-rGO-NB surface to construct a new CuNPs/PDA-rGO-NB/GCE sensing platform. Specific interactions of creatinine with Cu2+ ions from CuNPs surface led to regularly decreased peak current intensities located at -0.05 V (ICu2+) and negligible changes in peak current intensities located -0.325 V from NB (I-NB). There was a well plotted linear relationship between ICu2+/I-NB and creatinine concentration in the range from 0.01 to 100 mu M, with a low detection limit of 2 nM. This sensing platform enabled highly sensitive and selective responses towards creatinine, over potential interferents. In practical samples, this developed enzymeless ratiometric electrochemical sensor realized efficient detection of creatinine, showing high detection performance.
引用
收藏
页码:201 / 208
页数:8
相关论文
共 42 条
  • [1] Citrate-capped silver nanoparticles as a probe for sensitive and selective colorimetric and spectrophotometric sensing of creatinine in human urine
    Alula, Melisew Tadele
    Karamchand, Leshern
    Hendricks, Nicolette R.
    Blackburn, Jonathan M.
    [J]. ANALYTICA CHIMICA ACTA, 2018, 1007 : 40 - 49
  • [2] A conductometric creatinine biosensor prepared through contact printing of polyvinyl alcohol/polyethyleneimine based enzymatic membrane
    Braiek, Mohamed
    Djebbi, Mohamed Amine
    Chateaux, Jean-Francois
    Bonhomme, Anne
    Vargiolu, Roberto
    Bessueille, Francois
    Jaffrezic-Renault, Nicole
    [J]. MICROELECTRONIC ENGINEERING, 2018, 187 : 43 - 49
  • [3] Graphene Oxide: Preparation, Functionalization, and Electrochemical Applications
    Chen, Da
    Feng, Hongbin
    Li, Jinghong
    [J]. CHEMICAL REVIEWS, 2012, 112 (11) : 6027 - 6053
  • [4] An enzymeless electrochemical sensor for the selective determination of creatinine in human urine
    Chen, JC
    Kumar, AS
    Chung, HH
    Chien, SH
    Kuo, MC
    Zen, JM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 115 (01) : 473 - 480
  • [5] PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE
    COCKCROFT, DW
    GAULT, MH
    [J]. NEPHRON, 1976, 16 (01) : 31 - 41
  • [6] Development and characterization of an electrochemical biosensor for creatinine detection in human urine based on functional molecularly imprinted polymer
    Diouf, A.
    Motia, S.
    El Hassani, N. El Alami
    El Bari, N.
    Bouchikhi, B.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 44 - 53
  • [7] Mussel-Inspired Synthesis of Polydopamine-Functionalized Graphene Hydrogel as Reusable Adsorbents for Water Purification
    Gao, Hongcai
    Sun, Yimin
    Zhou, Jiajing
    Xu, Rong
    Duan, Hongwei
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (02) : 425 - 432
  • [8] Electrodeposition one-step preparation of silver nanoparticles/carbon dots/reduced graphene oxide ternary dendritic nanocomposites for sensitive detection of doxorubicin
    Guo, Huijun
    Jin, Hui
    Gui, Rijun
    Wang, Zonghua
    Xia, Jianfei
    Zhang, Feifei
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 253 : 50 - 57
  • [9] A mussel-inspired polydopamine coating as a versatile platform for the in situ synthesis of graphene-based nanocomposites
    Guo, Liangqia
    Liu, Qian
    Li, Guoliang
    Shi, Jianbo
    Liu, Jiyan
    Wang, Thanh
    Jiang, Guibin
    [J]. NANOSCALE, 2012, 4 (19) : 5864 - 5867
  • [10] Direct determination of creatinine based on poly(ethyleneimine)/phosphotungstic acid multilayer modified electrode
    Han, Ping
    Xu, Shimei
    Feng, Shun
    Hao, Yanjun
    Wang, Jide
    [J]. TALANTA, 2016, 151 : 114 - 118