Optimized coupling of an intermittent DC electric field with a membrane bioreactor for enhanced effluent quality and hindered membrane fouling

被引:59
|
作者
Tafti, Alireza Dehghani [1 ]
Mirzaii, Seyyed Morteza Seyyed [2 ]
Andalibi, Mohammad Reza [3 ]
Vossoughi, Manouchehr [2 ]
机构
[1] Shanf Univ Technol, Dept Civil & Environm, Biochem & Bioenvironm Engn Res Ctr, Tehran 1458889694, Iran
[2] Shanf Univ Technol, Dept Chem & Petr Engn, Biochem & Bioenvironm Engn Res Ctr, Tehran 1458889694, Iran
[3] Penn State Univ, Chem Engn, University Pk, PA 16802 USA
关键词
Submerged membrane electro-bioreactor; Membrane fouling; Wastewater treatment; Activated sludge properties; Soluble microbial products; WASTE-WATER; ELECTROCOAGULATION; FILTRATION; PERFORMANCE; SURFACE; IRON;
D O I
10.1016/j.seppur.2015.07.004
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This article studies a submerged membrane electro-bioreactor (SMEBR), an integrated system embracing biological treatment, electrical coagulation, and membrane filtration, all in one individual reactor, by applying an alternating electric field to a membrane bioreactor (MBR). The alternating electric field has been applied with current densities ranging from 5 to 23 A/m(2) under eight different electrical exposure modes. The results indicate that under the optimum condition with a current density of 12.5 A/m(2) and an exposure mode of (415 s OFF-185 s ON), the COD and phosphate removals would be respectively 4% and 43% more compared to an unmodified MBR system. Also at the same current density but with an exposure mode of (496 s OFF-104 s ON), ammonia removal efficiency was 22% more than the MBR system. At lower current density of 5 with an exposure mode (400 s OFF-200 s ON), the amounts of polysaccharides and proteins were respectively 59% and 51% less than ordinary membrane bioreactor. In summary, the SMEBR reactor membrane fouling is hindered while filtration course and particle size increase. Moreover, at current density less than 20 A/m(2) sludge activity enhances. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [21] Coupling of nanofiltration with microfiltration and membrane bioreactor for textile effluent reclamation
    Couto, Carolina Fonseca
    Marques, Larissa Silva
    Santos Amaral, Miriam Cristina
    Moravia, Wagner Guadagnin
    SEPARATION SCIENCE AND TECHNOLOGY, 2017, 52 (13) : 2150 - 2160
  • [22] Optimization of the operational parameters in a submerged membrane bioreactor using Box Behnken response surface methodology: membrane fouling control and effluent quality
    Asif, Muhammad Bilal
    Habib, Rasikh
    Iftekhar, Sidra
    Khan, Zahiruddin
    Majeed, Nadeem
    DESALINATION AND WATER TREATMENT, 2017, 82 : 26 - 38
  • [23] Effects of aeration parameters on effluent quality and membrane fouling in a submerged membrane bioreactor using Box-Behnken response surface methodology
    Fu, Hai-Yan
    Xu, Peng-Cheng
    Huang, Guo-He
    Chai, Tian
    Hou, Ming
    Gao, Pan-Feng
    DESALINATION, 2012, 302 : 33 - 42
  • [24] Development of a membrane-carbon cloth assembly for submerged membrane bioreactors to apply an intermittent electric field for fouling suppression
    Akamatsu, Kazuki
    Yoshida, Yoshio
    Suzaki, Takahiro
    Sakai, Yuji
    Nagamoto, Hidetoshi
    Nakao, Shin-ichi
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 88 : 202 - 207
  • [25] Understanding the effects of electrical exposure mode on membrane fouling in an electric anaerobic ceramic membrane bioreactor
    Su, Xiaoli
    Xing, Dingyu
    Song, Zi
    Dong, Wenyi
    Zhang, Mengdie
    Feng, Liang
    Wang, Mingming
    Sun, Feiyun
    JOURNAL OF MEMBRANE SCIENCE, 2022, 659
  • [26] Crossflow membrane filtration enhanced by an external DC electric field:: A review
    Huotari, HM
    Trägårdh, G
    Huisman, IH
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 1999, 77 (A5): : 461 - 468
  • [27] Crossflow membrane filtration enhanced by an external DC electric field: A review
    Huotari, H.M.
    Tragardh, G.
    Huisman, I.H.
    Chemical Engineering Research and Design, Transactions of the Institute of Chemical Engineers, Part A, 1999, 77 (A5): : 461 - 468
  • [28] Membrane Fouling Inversely Impacts Intracellular and Extracellular Antibiotic Resistance Gene Abundances in the Effluent of an Anaerobic Membrane Bioreactor
    Zarei-Baygi, Ali
    Wang, Phillip
    Harb, Moustapha
    Stadler, Lauren B.
    Smith, Adam L.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (19) : 12742 - 12751
  • [29] Enhanced membrane fouling control and trace organic compounds removal during microfiltration by coupling coagulation and adsorption in an electric field
    Du, Zhen
    Ji, Min
    Li, Ruying
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 795
  • [30] Performance and Mechanisms of Ultrafiltration Membrane Fouling Mitigation by Coupling Coagulation and Applied Electric Field in a Novel Electrocoagulation Membrane Reactor
    Sun, Jingqiu
    Hu, Chengzhi
    Tong, Tiezheng
    Zhao, Kai
    Qu, Jiuhui
    Liu, Huijuan
    Elimelech, Menachem
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2017, 51 (15) : 8544 - 8551