Respiration rate and volume measurements using wearable strain sensors

被引:265
作者
Chu, Michael [1 ]
Thao Nguyen [2 ]
Pandey, Vaibhav [3 ]
Zhou, Yongxiao [1 ]
Pham, Hoang N. [4 ]
Bar-Yoseph, Ronen [4 ,5 ]
Radom-Aizik, Shlomit [4 ]
Jain, Ramesh [3 ]
Cooper, Dan M. [4 ]
Khine, Michelle [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Chem Engn, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Bren Sch Informat & Comp Sci, Irvine, CA USA
[4] Univ Calif Irvine, Sch Med, Pediat Exercise & Genom Res Ctr, Irvine, CA 92717 USA
[5] Rambam Med Ctr, Dept Pediat, Haifa, Israel
关键词
MEASURING TIDAL VOLUME; OPTOELECTRONIC PLETHYSMOGRAPHY; INDUCTIVE PLETHYSMOGRAPHY; ECONOMIC BURDEN; ACCURACY; CALIBRATION; SLEEP;
D O I
10.1038/s41746-019-0083-3
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Current methods for continuous respiration monitoring such as respiratory inductive or optoelectronic plethysmography are limited to clinical or research settings; most wearable systems reported only measures respiration rate. Here we introduce a wearable sensor capable of simultaneously measuring both respiration rate and volume with high fidelity. Our disposable respiration sensor with a Band-Aid (c) like formfactor can measure both respiration rate and volume by simply measuring the local strain of the ribcage and abdomen during breathing. We demonstrate that both metrics are highly correlated to measurements from a medical grade continuous spirometer on participants at rest. Additionally, we also show that the system is capable of detecting respiration under various ambulatory conditions. Because these low-powered piezo-resistive sensors can be integrated with wireless Bluetooth units, they can be useful in monitoring patients with chronic respiratory diseases in everyday settings.
引用
收藏
页数:9
相关论文
共 39 条
[1]   Respiration Rate Monitoring Methods: A Review [J].
AL-Khalidi, F. Q. ;
Saatchi, R. ;
Burke, D. ;
Elphick, H. ;
Tan, S. .
PEDIATRIC PULMONOLOGY, 2011, 46 (06) :523-529
[2]   Optoelectronic plethysmography in intensive care patients [J].
Aliverti, A ;
Dellacà, R ;
Pelosi, P ;
Chiumello, D ;
Pedotti, A ;
Gattinoni, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (05) :1546-1552
[3]   Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review [J].
Amjadi, Morteza ;
Kyung, Ki-Uk ;
Park, Inkyu ;
Sitti, Metin .
ADVANCED FUNCTIONAL MATERIALS, 2016, 26 (11) :1678-1698
[4]  
Aoki H, 2012, 2012 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), P614
[5]   Statistical methods for assessing agreement between two methods of clinical measurement [J].
Bland, J. Martin ;
Altman, Douglas G. .
INTERNATIONAL JOURNAL OF NURSING STUDIES, 2010, 47 (08) :931-936
[6]   Clinical review: Respiratory monitoring in the ICU - a consensus of 16 [J].
Brochard, Laurent ;
Martin, Greg S. ;
Blanch, Lluis ;
Pelosi, Paolo ;
Belda, F. Javier ;
Jubran, Amal ;
Gattinoni, Luciano ;
Mancebo, Jordi ;
Ranieri, V. Marco ;
Richard, Jean-Christophe M. ;
Gommers, Diederik ;
Vieillard-Baron, Antoine ;
Pesenti, Antonio ;
Jaber, Samir ;
Stenqvist, Ola ;
Vincent, Jean-Louis .
CRITICAL CARE, 2012, 16 (02)
[7]   ACCURACY OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY DURING WAKEFULNESS AND SLEEP IN PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
CANTINEAU, JP ;
ESCOURROU, P ;
SARTENE, R ;
GAULTIER, C ;
GOLDMAN, M .
CHEST, 1992, 102 (04) :1145-1151
[8]   RELIABILITY OF RESPIRATORY INDUCTIVE PLETHYSMOGRAPHY FOR MEASURING TIDAL VOLUME DURING EXERCISE [J].
CARETTI, DM ;
PULLEN, PV ;
PREMO, LA ;
KUHLMANN, WD .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (10) :918-923
[9]  
Collop NA, 2007, J CLIN SLEEP MED, V3, P737
[10]   CURRENT CONCEPTS - PULMONARY-FUNCTION TESTING [J].
CRAPO, RO .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (01) :25-30