New classification of ophthalmic viscosurgical devices - 2005

被引:69
|
作者
Arshinoff, SA
Jafari, M
机构
[1] York Finch Eye Assoc, Toronto, ON M3N 2V6, Canada
[2] Humber River Reg Hosp, Toronto, ON, Canada
[3] Univ Toronto, Toronto, ON, Canada
[4] Alcon Res Ltd, Surg Formulat Dev, Ft Worth, TX USA
来源
关键词
D O I
10.1016/j.jcrs.2005.08.056
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To revise the generally accepted classification of ophthalmic viscosurgical devices (OVDs) to include cohesion data and the new class of viscous dispersive OVDs. SETTING: York Finch Eye Associates, Toronto, Ontario, Canada, and Alcon Research Limited, Fort Worth, Texas, USA. METHODS: Pseudo plasticity and cohesion-dispersion (CDI) data of DisCoVisc (hyaluronic acid 1.6%-chondroitin sulfate 4%), a new viscous dispersive OVD, were determined and compared with existing OVDs. The existing classification of OVDs was unable to accommodate its properties, so the classification was modified to include a new class and other potential new classes which currently remain unoccupied. RESULTS: Current OVD classification, although based on the clinically significant rheologic parameters of zero-shear viscosity and cohesion, only uses zero-shear viscosity because of the high correlation of these 2 parameters in existing OVDs. The appearance of DisCoVisc forces modification of the existing scheme because it does not fit into a preexisting category. The new proposed broadened classification is changed from a 1-dimensional list into a 2-dimensional table and considers CDI independently from viscosity for all OVDs. Expansion of the classification of OVDs in this manner predicts further possible new innovative OVDs for surgical use. CONCLUSION: The surgical behavior of OVDs can be predicted by their position in a classification of OVDs based upon zero-shear viscosity and cohesion.
引用
收藏
页码:2167 / 2171
页数:5
相关论文
共 50 条
  • [21] Bimanual RetroIOL aspiration for complete removal of ophthalmic viscosurgical devices
    Dada, T
    Dada, VK
    Sethi, HS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (04): : 852 - 852
  • [22] Understanding, retaining, and removing dispersive and pseudodispersive ophthalmic viscosurgical devices
    Arshinoff, SA
    Wong, E
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12): : 2318 - 2323
  • [23] Alteration of free radical development by ophthalmic viscosurgical devices in phacoemulsification
    Takahashi, Hiroshi
    Suzuki, Hisaharu
    Shiwa, Toshihiko
    Sakamoto, Atsuhiro
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (09): : 1545 - 1548
  • [24] Mixed polymeric systems: New ophthalmic viscosurgical device created by mixing commercially available devices
    Tognetto, Daniele
    Cecchini, Paolo
    D'Aloisio, Rossella
    Lapasin, Romano
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (01): : 109 - 114
  • [25] Rheological and Adhesive Properties to Identify Cohesive and Dispersive Ophthalmic Viscosurgical Devices
    Watanabe, Ippei
    Hoshi, Hirotaka
    Sato, Miwako
    Suzuki, Kiyoshi
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2019, 67 (03) : 277 - 283
  • [26] The Use of Ophthalmic Viscosurgical Devices During Donor's Corneal Harvesting
    Bor, Elite
    Bourla, Dan H.
    Kaiserman, Igor
    Kremer, Israel
    Bahar, Irit
    CURRENT EYE RESEARCH, 2013, 38 (06) : 626 - 629
  • [27] Impact of temperature on ophthalmic viscosurgical devices and clinical implications: a pilot study
    Henry, Caoimhe
    Castro, Alejandro Thompson
    Belkessa, Mohamed
    Rycroft, Ewan
    Syntouka, Ioanna M.
    Silva, Andreia F.
    Sillars, Fiona
    Oliveira, Monica S. N.
    Lockington, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (11): : 1173 - 1179
  • [28] Novel Model Development for Preclinical Safety Evaluation of Ophthalmic Viscosurgical Devices
    Huang, Ling C.
    Gray, Brad
    Leang, Ronika
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [29] Oxidative tissue damage after phacoemulsification: Influence of ophthalmic viscosurgical devices
    Augustin, AJ
    Dick, HB
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (02): : 424 - 427
  • [30] Addition Of D-Sorbitol Improves The Usability Of Ophthalmic Viscosurgical Devices
    Watanabe, Ippei
    Nagata, Mayumi
    Matsushima, Hiroyuki
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 1877 - 1885