Errors in MR-based attenuation correction for brain imaging with PET/MR scanners

被引:2
|
作者
Kops, Elena Rota [1 ]
Herzog, Hans [1 ]
机构
[1] Forschungszentrum Juelich, INM4, Julich, Germany
关键词
MR/PET; Template-based attenuation correction; Errors;
D O I
10.1016/j.nima.2012.09.032
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Aim: Attenuation correction of PET data acquired by hybrid MR/PET scanners remains a challenge, even if several methods for brain and whole-body measurements have been developed recently. A template-based attenuation correction for brain imaging proposed by our group is easy to handle and delivers reliable attenuation maps in a short time. However, some potential error sources are analyzed in this study. We investigated the choice of template reference head among all the available data (error A), and possible skull anomalies of the specific patient, such as discontinuities due to surgery (error B). Materials and methods: An anatomical MR measurement and a 2-bed-position transmission scan covering the whole head and neck region were performed in eight normal subjects (4 females, 4 males). Error A: Taking alternatively one of the eight heads as reference, eight different templates were created by nonlinearly registering the images to the reference and calculating the average. Eight patients (4 females, 4 males; 4 with brain lesions, 4 w/o brain lesions) were measured in the Siemens BrainPET/MR scanner. The eight templates were used to generate the patients' attenuation maps required for reconstruction. ROI and VOI atlas-based comparisons were performed employing all the reconstructed images. Error B: CT-based attenuation maps of two volunteers were manipulated by manually inserting several skull lesions and filling a nasal cavity. The corresponding attenuation coefficients were substituted with the water's coefficient (0.096/cm). Results: Error A: The mean SUVs over the eight templates pairs for all eight patients and all VOIs did not differ significantly one from each other. Standard deviations up to 1.24% were found. Error B: After reconstruction of the volunteers' BrainPET data with the CT-based attenuation maps without and with skull anomalies, a VOI-atlas analysis was performed revealing very little influence of the skull lesions (less than 3%), while the filled nasal cavity yielded an overestimation in cerebellum up to 5%. Conclusions: The present error analysis confirms that our template-based attenuation method provides reliable attenuation corrections of PET brain imaging measured in PET/MR scanners. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:104 / 107
页数:4
相关论文
共 50 条
  • [11] MR-BASED ATTENUATION MAP RE-ALIGNMENT AND MOTION CORRECTION IN SIMULTANEOUS BRAIN MR-PET IMAGING
    Sforazzini, Francesco
    Chen, Zhaolin
    Baran, Jakub
    Bradley, Jason
    Carey, Alexandra
    Shah, N. Jon
    Egan, Gary
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 231 - 234
  • [12] MR-based attenuation correction for hybrid PET-MR brain imaging systems using deformable image registration
    Schreibmann, Eduard
    Nye, Jonathon A.
    Schuster, David M.
    Martin, Diego R.
    Votaw, John
    Fox, Tim
    MEDICAL PHYSICS, 2010, 37 (05) : 2101 - 2109
  • [13] Effect of sinus attenuation in MR-based attenuation correction in 18F-FDG brain PET/MR
    Teuho, J.
    Tuisku, J.
    Linden, J.
    Teras, M.
    EMBEC & NBC 2017, 2018, 65 : 266 - 269
  • [14] MR-based attenuation correction for torso-PET/MR imaging:: pitfalls in mapping MR to CT data
    Beyer, Thomas
    Weigert, Markus
    Quick, Harald H.
    Pietrzyk, Uwe
    Vogt, Florian
    Palm, Christoph
    Antoch, Gerald
    Mueller, Stefan P.
    Bockisch, Andreas
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (06) : 1142 - 1146
  • [15] Evaluation of three methods for delineation and attenuation estimation of the sinus region in MR-based attenuation correction for brain PET-MR imaging
    Linden, Jani
    Teuho, Jarmo
    Teras, Mika
    Klen, Riku
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [16] Evaluation of three methods for delineation and attenuation estimation of the sinus region in MR-based attenuation correction for brain PET-MR imaging
    Jani Lindén
    Jarmo Teuho
    Mika Teräs
    Riku Klén
    BMC Medical Imaging, 22
  • [17] The effect of positioning aids on PET quantification following MR-based attenuation correction (AC) in PET/MR imaging
    Mantlik, Frederic
    Hofmann, Matthias
    Kupferschlaeger, Juergen
    Werner, Matthias
    Pichler, Bernd
    Beyer, Thomas
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [18] Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging
    Blumhagen, Jan O.
    Braun, Harald
    Ladebeck, Ralf
    Fenchel, Matthias
    Faul, David
    Scheffler, Klaus
    Quick, Harald H.
    MEDICAL PHYSICS, 2014, 41 (02)
  • [19] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [20] Influence and Compensation of Truncation Artifacts in MR-Based Attenuation Correction in PET/MR
    Schramm, G.
    Langner, J.
    Hofheinz, F.
    Petr, J.
    Lougovski, A.
    Beuthien-Baumann, B.
    Platzek, I.
    van den Hoff, J.