Regulating reserve with large penetration of renewable energy using midterm dynamic simulation

被引:4
作者
Jing, Chaoyang [1 ]
Li, Baiqing [2 ]
机构
[1] eMIT LLC, Pasadena, CA 91107 USA
[2] China Elect Power Res Inst, Beijing, Peoples R China
关键词
Renewable energy intermittency; Midterm dynamic simulation; Power systems; Dynamic stability; Renewable portfolio standard (RPS);
D O I
10.1007/s40565-013-0006-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel renewable energy intermittency model and a new midterm dynamic simulation tool in power systems are developed for examining dynamic behavior along the load curve for different combinations of the system operation reserves and renewable portfolio standard (RPS) rates. The system's import limits are considered. It is concluded that ignoring intermittency and governor effects is an inadequate method to assess intermittency impact. The intermittency midterm dynamic impact must be studied. For the studied system, the instability is expected to be about 25 % RPS with current reserves. Besides, the most vulnerable peak hour to instability is the afternoon peak hour when solar begins to drop off. This article stimulates further dynamic intermittency studies on the issues caused by renewable intermittency. The studies on the issues caused by renewable intermittency have not been revealed because of inadequate/incomprehensive study methodologies so that effective, mitigative solutions can be developed to guarantee the reliability of power grid when incorporating higher RPS if high operation reserves are impractical.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 17 条
[1]  
[Anonymous], 2009, MODELING GE SOLAR PH
[2]  
Bergen A.R., 2000, Power System Analysis, V2nd
[3]  
Bonneville Power Administration, 2007, LARG WIND INT IMP OP
[4]  
California ISO, 2010, INT REN RES OP REQ G
[5]   Online dynamic security assessment in an EMS [J].
Ejebe, GC ;
Jing, C ;
Waight, JG ;
Vittal, V ;
Pieper, G ;
Jamshidian, F ;
Hirsch, P ;
Sobajic, D .
IEEE COMPUTER APPLICATIONS IN POWER, 1998, 11 (01) :43-47
[6]  
Ela E, 2010, IEEE POW ENER SOC GE
[7]  
EnerNex Corporation, 2006, FIN REP ENERNEX CORP, V1
[8]  
ISO, 2010, CPUC WORKSH CAISO PG
[9]   INCORPORATION OF HVDC AND SVC MODELS IN THE NORTHERN-STATE-POWER-CO (NSP) NETWORK FOR ONLINE IMPLEMENTATION OF DIRECT TRANSIENT STABILITY ASSESSMENT [J].
JING, C ;
VITTAL, V ;
EJEBE, GC ;
IRISARRI, GD .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :898-904
[10]  
Kehler J, 2010, P 2010 IEEE POW EN S