Noninvasive determination of optical lever sensitivity in atomic force microscopy

被引:185
作者
Higgins, MJ
Proksch, R
Sader, JE
Polcik, M
Mc Endoo, S
Cleveland, JP
Jarvis, SP
机构
[1] Univ Dublin Trinity Coll, CRANN, Dublin 2, Ireland
[2] Asylum Res, Santa Barbara, CA 93117 USA
[3] Univ Melbourne, Dept Math & Stat, Melbourne, Vic 3010, Australia
基金
爱尔兰科学基金会; 澳大利亚研究理事会;
关键词
D O I
10.1063/1.2162455
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Atomic force microscopes typically require knowledge of the cantilever spring constant and optical lever sensitivity in order to accurately determine the force from the cantilever deflection. In this study, we investigate a technique to calibrate the optical lever sensitivity of rectangular cantilevers that does not require contact to be made with a surface. This noncontact approach utilizes the method of Sader [Rev. Sci. Instrum. 70, 3967 (1999)] to calibrate the spring constant of the cantilever in combination with the equipartition theorem [J. L. Hutter and J. Bechhoefer, Rev. Sci. Instrum. 64, 1868 (1993)] to determine the optical lever sensitivity. A comparison is presented between sensitivity values obtained from conventional static mode force curves and those derived using this noncontact approach for a range of different cantilevers in air and liquid. These measurements indicate that the method offers a quick, alternative approach for the calibration of the optical lever sensitivity. (c) 2006 American Institute of Physics.
引用
收藏
页码:1 / 5
页数:5
相关论文
共 16 条
  • [1] AN ATOMIC-RESOLUTION ATOMIC-FORCE MICROSCOPE IMPLEMENTED USING AN OPTICAL-LEVER
    ALEXANDER, S
    HELLEMANS, L
    MARTI, O
    SCHNEIR, J
    ELINGS, V
    HANSMA, PK
    LONGMIRE, M
    GURLEY, J
    [J]. JOURNAL OF APPLIED PHYSICS, 1989, 65 (01) : 164 - 167
  • [2] ATOMIC FORCE MICROSCOPE
    BINNIG, G
    QUATE, CF
    GERBER, C
    [J]. PHYSICAL REVIEW LETTERS, 1986, 56 (09) : 930 - 933
  • [3] Brar LK, 2002, CURR SCI INDIA, V83, P1197
  • [4] Comparison of calibration methods for atomic-force microscopy cantilevers
    Burnham, NA
    Chen, X
    Hodges, CS
    Matei, GA
    Thoreson, EJ
    Roberts, CJ
    Davies, MC
    Tendler, SJB
    [J]. NANOTECHNOLOGY, 2003, 14 (01) : 1 - 6
  • [5] CALCULATION OF THERMAL NOISE IN ATOMIC-FORCE MICROSCOPY
    BUTT, HJ
    JASCHKE, M
    [J]. NANOTECHNOLOGY, 1995, 6 (01) : 1 - 7
  • [6] A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY
    CLEVELAND, JP
    MANNE, S
    BOCEK, D
    HANSMA, PK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) : 403 - 405
  • [7] CLEVELAND JP, 1999, SOM DIGEST NOV
  • [8] In situ calibration of colloid probe cantilevers in force microscopy: Hydrodynamic drag on a sphere approaching a wall
    Craig, VSJ
    Neto, C
    [J]. LANGMUIR, 2001, 17 (19) : 6018 - 6022
  • [9] DCOSTA NP, 1995, REV SCI INSTRUM, V66, P5097
  • [10] CALIBRATION OF ATOMIC-FORCE MICROSCOPE TIPS
    HUTTER, JL
    BECHHOEFER, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (07) : 1868 - 1873