Sizing optimization, dynamic modeling and energy management strategies of a stand-alone PV/hydrogen/battery-based hybrid system

被引:204
|
作者
Castaneda, Manuel [1 ]
Cano, Antonio [2 ]
Jurado, Francisco [2 ]
Sanchez, Higinio [3 ]
Fernandez, Luis M. [1 ]
机构
[1] Univ Cadiz, EPS Algeciras, Dept Elect Engn, Algeciras 11202, Cadiz, Spain
[2] Univ Jaen, EPS Linares, Dept Elect Engn, Linares 23700, Jaen, Spain
[3] Univ Cadiz, ESI Cadiz, Dept Elect Engn, Cadiz 11002, Spain
关键词
Sizing optimization; Hydrogen; Battery; Photovoltaic; Control strategies; POWER-GENERATION SYSTEM; RENEWABLE ENERGY; HYDROGEN-PRODUCTION; SIMULATION; STORAGE;
D O I
10.1016/j.ijhydene.2013.01.080
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This paper presents a sizing method and different control strategies for the suitable energy management of a stand-alone hybrid system based on photovoltaic (PV) solar panels, hydrogen subsystem and battery. The battery and hydrogen subsystem, which is composed of fuel cell (FC), electrolyzer and hydrogen storage tank, act as energy storage and support system. In order to efficiently utilize the energy sources integrated in the hybrid system, an appropriate sizing is necessary. In this paper, a new sizing method based on Simulink Design Optimization (SDO) of MATLAB was used to perform a technical optimization of the hybrid system components. An analysis cost has been also performed, in that the configuration under study has been compared with those integrating only batteries and only hydrogen system. The dynamic model of the designed hybrid system is detailed in this paper. The models, implemented in MATLAB-Simulink environment, have been designed from commercially available components. Three control strategies based on operating modes and combining technical-economic aspects are considered for the energy management of the hybrid system. They have been designed, primarily, to satisfy the load power demand and, secondarily, to maintain a certain level at the hydrogen tank (hydrogen energy reserve), and at the state of charge (SOC) of the battery bank to extend its life, taking into account also technical-economic analysis. Dynamic simulations were performed to evaluate the configuration, sizing and control strategies for the energy management of the hybrid system under study in this work. Simulation results show that the proposed hybrid system with the presented controls is able to provide the energy demanded by the loads, while maintaining a certain energy reserve in the storage sources. Copyright (C) 2013, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:3830 / 3845
页数:16
相关论文
共 50 条
  • [21] The effect of components capacity loss on the performance of a hybrid PV/ wind/battery/hydrogen stand-alone energy system
    Simunovic, Jakov
    Radica, Gojmir
    Barbir, Frano
    ENERGY CONVERSION AND MANAGEMENT, 2023, 291
  • [22] Dynamic modeling and sizing optimization of stand-alone photovoltaic power systems using hybrid energy storage technology
    Li, Chun-Hua
    Zhu, Xin-Jian
    Cao, Guang-Yi
    Sui, Sheng
    Hu, Ming-Ruo
    RENEWABLE ENERGY, 2009, 34 (03) : 815 - 826
  • [23] Robust optimal sizing of a hybrid energy stand-alone system
    Billionnet, Alain
    Costa, Marie-Christine
    Poirion, Pierre-Louis
    EUROPEAN JOURNAL OF OPERATIONAL RESEARCH, 2016, 254 (02) : 565 - 575
  • [24] Modeling and Optimization of Wind/PV System for Stand-Alone Site
    Belfkira, Rachid
    Nichita, Cristian
    Barakat, Georges
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 429 - 434
  • [25] Smart Hybrid Energy Storage for Stand-alone PV Microgrid: Optimization of Battery Lifespan through Dynamic Power Allocation
    Jing, Wenlong
    Wong, M. L. Dennis
    Lai, Chean Hung
    Wong, Wallace Shun Hui
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [26] Modeling and Intelligent control of a Stand-alone PV-Wind-Diesel-Battery Hybrid System
    Ai-Barazanchi, Sardar Adil Mohammed
    Vurau, Ahmet Mete
    2015 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2015, : 423 - 430
  • [27] A STAND-ALONE HYBRID POWER SYSTEM BASED ON PV ENERGY AND HYDROGEN FUEL CELLS WITH ENERGY STORAGE SYSTEMS
    Issa, Hayder abdulsahib
    Abdali, Layth mohammed
    Velkin, Vladimir i.
    MM SCIENCE JOURNAL, 2024, 2024 : 8003 - 8009
  • [28] Optimal Sizing of Stand-alone PV System Using Grey Wolf Optimization
    Khalil, Ashraf
    Asheibi, Ali
    2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING RESEARCH & PRACTICE (ICEERP-2019), 2019, : 88 - 93
  • [29] Stand-alone PV system based on new structure of hybrid energy storage
    Zhang, Yingchao
    Long, Jiangtao
    Guo, Zhen
    Zhang, Yangjun
    Qian, Xisen
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2014, 35 (12): : 2461 - 2467
  • [30] Multi-objective genetic algorithm based sizing optimization of a stand-alone wind/PV power supply system with enhanced battery/supercapacitor hybrid energy storage
    Abdelkader, Abbassi
    Rabeh, Abbassi
    Ali, Dami Mohamed
    Mohamed, Jemli
    ENERGY, 2018, 163 : 351 - 363