Comparison of the diagnostic performances of two protocols of hand perfusion scintigraphy for Raynaud's phenomenon

被引:7
|
作者
Lee, Jeong Won [2 ]
Jeong, Woo Seong [1 ]
Lee, Sang Mee [3 ]
Kim, Jinseok [1 ]
机构
[1] Jeju Natl Univ, Jeju Natl Univ Hosp, Sch Med, Dept Internal Med, Jeju City 690767, Jeju Do, South Korea
[2] Jeju Natl Univ, Jeju Natl Univ Hosp, Sch Med, Dept Nucl Med, Jeju City 690767, Jeju Do, South Korea
[3] Soonchunhyang Univ Hosp, Dept Nucl Med, Cheonan, South Korea
关键词
diagnostic performance; Raynaud's phenomenon; Tc-99m-methylene diphosphonate scintigraphy; GEOGRAPHIC-VARIATION; PREVALENCE; TRANSITION; FINGERS; FORMS;
D O I
10.1097/MNM.0b013e3283567492
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective The aim of this study was to compare the diagnostic performances of two hand perfusion scintigraphy protocols for diagnosing Raynaud's phenomenon (RP). Methods We enrolled 130 patients who underwent hand perfusion scintigraphy for suspected RP and 40 normal controls. Of these, 66 patients (group A) and 25 normal controls underwent Tc-99m-methylene diphosphonate hand perfusion scintigraphy without one-hand chilling, and the finger-to-palm ratio (FPR) was calculated. The remaining 64 patients (group B) and 15 normal controls underwent Tc-99m-methylene diphosphonate hand perfusion scintigraphy with one-hand chilling, and three parameters (the chilled-to-ambient hand ratios of the first peak height, initial slope, and blood pool uptake) were calculated. Results Forty-eight and 47 patients were clinically diagnosed with RP in groups A and B, respectively. In group A, patients with RP had significantly lower FPRs compared with those without RP, and the receiver operating characteristic curve analysis showed that an FPR of 0.51 was the best cutoff value for diagnosing RP, with a sensitivity of 63% and a specificity of 83%. In group B, the three aforementioned parameters differed significantly (lower or higher) between patients with and without RP. The receiver operating characteristic curve analysis provided highly sensitive and specific results for all three parameters. The initial slope ratio showed the highest sensitivity of 87% and a specificity of 88% when using cutoff values of 0.78 and 1.25. Conclusion Although both protocols for hand perfusion scintigraphy showed high specificity for diagnosing RP, the protocol with one-hand chilling showed higher diagnostic ability compared with that without one-hand chilling. Nucl Med Commun 33:1032-1038 (C) 2012 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
引用
收藏
页码:1032 / 1038
页数:7
相关论文
共 40 条
  • [1] Perfusion Scintigraphy for the Evaluation of Patients with Raynaud's Phenomenon
    Chong, Ari
    NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 54 (06) : 269 - 273
  • [2] Perfusion Scintigraphy for the Evaluation of Patients with Raynaud’s Phenomenon
    Ari Chong
    Nuclear Medicine and Molecular Imaging, 2020, 54 : 269 - 273
  • [3] The use of hand perfusion scintigraphy to assess Raynaud's phenomenon associated with hand-arm vibration syndrome
    Lee, K. -A.
    Chung, H. W.
    Lee, S. -H.
    Kim, H. -R.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2017, 35 (04) : S138 - S143
  • [4] Diagnosis of Raynaud’s phenomenon by 99mTc-pertechnetate hand perfusion scintigraphy: a pilot study
    Slavica Pavlov-Dolijanovic
    Nebojsa Petrovic
    Nada Vujasinovic Stupar
    Nemanja Damjanov
    Goran Radunovic
    Dragan Babic
    Dragana Sobic-Saranovic
    Vera Artiko
    Rheumatology International, 2016, 36 : 1683 - 1688
  • [5] Diagnosis of Raynaud's phenomenon by 99mTc-pertechnetate hand perfusion scintigraphy: a pilot study
    Pavlov-Dolijanovic, Slavica
    Petrovic, Nebojsa
    Vujasinovic Stupar, Nada
    Damjanov, Nemanja
    Radunovic, Goran
    Babic, Dragan
    Sobic-Saranovic, Dragana
    Artiko, Vera
    RHEUMATOLOGY INTERNATIONAL, 2016, 36 (12) : 1683 - 1688
  • [6] Current diagnostic and treatment of Raynaud's phenomenon
    Caspary, L.
    Creutzig, A.
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2006, 131 (21) : 1223 - 1227
  • [7] Technetium-99m hand perfusion scintigraphy (Raynaud?s scan) as a method of verification in hand arm vibration syndrome: a review
    Ha, Taewoong
    Oh, Hyeoncheol
    Kim, Jungwon
    ANNALS OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2022, 34
  • [8] Comparison of different forms of Raynaud?s phenomenon by LASCA proximal-distal gradient perfusion
    Di Battista, Marco
    Morganti, Riccardo
    Da Rio, Mattia
    De Mattia, Giammarco
    Della Rossa, Alessandra
    Mosca, Marta
    MICROVASCULAR RESEARCH, 2023, 148
  • [9] Raynaud's Phenomenon and Hand Function in Patients with Rheumatoid Arthritis
    Tansey, Rosamond J.
    Wragg, Elizabeth A.
    Herrick, Ariane L.
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (06) : 1358 - 1359
  • [10] Geographic variation in the prevalence of Raynaud's phenomenon: A 5 region comparison
    Maricq, HR
    Carpentier, PH
    Weinrich, MC
    Keil, JE
    Palesch, Y
    Biro, C
    VionnetFuasset, M
    Jiguet, M
    Valter, I
    JOURNAL OF RHEUMATOLOGY, 1997, 24 (05) : 879 - 889