Assay of steroids by liquid chromatography-tandem mass spectrometry in monitoring 21-hydroxylase deficiency

被引:17
作者
Dahl, Sandra R. [1 ]
Nermoen, Ingrid [2 ,3 ]
Bronstad, Ingeborg [4 ,5 ]
Husebye, Eystein S. [6 ,7 ,8 ]
Lovas, Kristian [6 ,7 ,8 ]
Thorsby, Per M. [1 ]
机构
[1] Oslo Univ Hosp, Dept Med Biochem, Hormone Lab, Oslo, Norway
[2] Univ Oslo, Inst Clin Med, Oslo, Norway
[3] Akershus Univ Hosp, Div Med, Lorenskog, Norway
[4] Haukeland Hosp, Natl Ctr Ultrasound Gastroenterol, Bergen, Norway
[5] Univ Bergen, Dept Clin Med, Bergen, Norway
[6] Univ Bergen, Dept Clin Sci, Bergen, Norway
[7] Univ Bergen, KG Jebsen Ctr Autoimmune Dis, Bergen, Norway
[8] Haukeland Hosp, Dept Med, Bergen, Norway
来源
ENDOCRINE CONNECTIONS | 2018年 / 7卷 / 12期
关键词
21-hydroxylase deficiency; congenital adrenal hyperplasia; LC-MS/MS; monitoring; adrenal glucocorticoid quantitation; adrenal androgens quantitation; CONGENITAL ADRENAL-HYPERPLASIA; PCR-BASED DIAGNOSIS; PLASMA; 21-DEOXYCORTISOL; GENETIC DIAGNOSIS; TESTOSTERONE; WOMEN; IMMUNOASSAYS; MANAGEMENT; CARRIERS; MARKERS;
D O I
10.1530/EC-18-0453
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Immunoassays of steroid hormones are still used in the diagnosis and monitoring of patients with congenital adrenal hyperplasia. However, cross-reactivity between steroids can give rise to falsely elevated steroid levels. Here, we compare the use of immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the monitoring of patients with classic 21-hydroxylase deficiency (21OHD). Steroid profiles in different mutation groups (genotypes) were also compared. Fifty-five patients with classic 21OHD (38 women) were studied. Blood samples were collected in the morning after an overnight medication fast. LC-MS/MS and immunoassays were employed to assay 17-hydroxyprogesterone (17OHP), testosterone and androstenedione. In addition, 21-deoxycortisol (21DF), 11-deoxycortisol (11DF), corticosterone, deoxycorticosterone, cortisone and cortisol were analyzed by LC-MS/MS. Testosterone, androstenedione and 17OHP levels were consistently lower (by about 30-50%) when measured by LC-MS/ MS compared with immunoassays, with exception of testosterone in men. There was a significant correlation between 21DF and 17OHP (r=0.87, P<0.001), but three patients had undetectable 21DF. Subjects with no enzyme activity had significantly lower mean 11DF concentrations than subjects with residual activity. The use of LC-MS/MS gives a more specific view of adrenal steroid levels in 21OHD compared with immunoassays, which seem to considerably overestimate the levels of 17OHP and androstenedione. Falsely elevated levels of 17OHP and androstenedione could lead to overtreatment with glucocorticoids.
引用
收藏
页码:1542 / 1550
页数:9
相关论文
共 50 条
  • [31] Screening for Nonclassic Congenital Adrenal Hyperplasia in the Era of Liquid Chromatography-Tandem Mass Spectrometry
    Chesover, Alexander D.
    Millar, Heather
    Sepiashvili, Lusia
    Adeli, Khosrow
    Palmert, Mark R.
    Hamilton, Jill
    [J]. JOURNAL OF THE ENDOCRINE SOCIETY, 2020, 4 (02)
  • [32] Simultaneous determination of β-agonists and monitoring in bovine tissues by liquid chromatography-tandem mass spectrometry
    Jeong, Kyunghun
    Hossain, Md Akil
    Park, Hae-chul
    Son, Seong-Wan
    Kang, JeongWoo
    [J]. ACTA VETERINARIA BRNO, 2018, 87 (01) : 47 - +
  • [33] Monitoring Salivary Melatonin Concentrations in Children With Sleep Disorders Using Liquid Chromatography-Tandem Mass Spectrometry
    Khan, Sohil A.
    George, Rani
    Charles, Bruce G.
    Taylor, Paul J.
    Heussler, Helen S.
    Cooper, David M.
    McGuire, Treasure M.
    Pache, David
    Norris, Ross L. G.
    [J]. THERAPEUTIC DRUG MONITORING, 2013, 35 (03) : 388 - 395
  • [34] Simultaneous quantification of individual intermediate steroids in silkworm ecdysone biosynthesis by liquid chromatography-tandem mass spectrometry with multiple reaction monitoring
    Hikiba, Juri
    Ogihara, Mari H.
    Iga, Masatoshi
    Saito, Kazuki
    Fujimoto, Yoshinori
    Suzuki, Minoru
    Kataoka, Hiroshi
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 915 : 52 - 56
  • [35] Performance evaluation of Siemens ADVIA Centaur® enhanced estradiol assay and a split sample comparison with liquid chromatography-tandem mass spectrometry
    Chen, Yu
    Kinney, Lois
    Soldin, Steven J.
    [J]. CLINICAL BIOCHEMISTRY, 2012, 45 (10-11) : 811 - 815
  • [36] Clopidogrel and acetylsalycilic acid therapy monitoring by liquid chromatography tandem mass spectrometry
    Luchessi, A. D.
    Concheiro, M.
    Quintela, O.
    Hirata, R. D. C.
    Brion, M.
    Carracedo, A.
    Iniguez, A.
    Lopez-Rivadulla, M.
    Hirata, M. H.
    [J]. THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 500 - 500
  • [37] Implementation of a Liquid Chromatography Tandem Mass Spectrometry Assay for Eight Adrenal C-21 Steroids and Pediatric Reference Data
    Kulle, Alexandra E.
    Welzel, Maik
    Holterhus, Paul-Martin
    Riepe, Felix G.
    [J]. HORMONE RESEARCH IN PAEDIATRICS, 2013, 79 (01): : 22 - 31
  • [38] Determination of serum amantadine by liquid chromatography-tandem mass spectrometry
    Arndt, T
    Guessregen, B
    Hohl, A
    Reis, J
    [J]. CLINICA CHIMICA ACTA, 2005, 359 (1-2) : 125 - 131
  • [39] Determination of testosterone in serum by liquid chromatography-tandem mass spectrometry
    Turpeinen, U.
    Linko, S.
    Itkonen, O.
    Hamalainen, E.
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2008, 68 (01) : 50 - 57
  • [40] Determination of raloxifene and its glucuronides in human urine by liquid chromatography-tandem mass spectrometry assay
    Trdan, Tina
    Roskar, Robert
    Trontelj, Jurij
    Ravnikar, Matjaz
    Mrhar, Ales
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2323 - 2331