OPTIMAL AEROSOL DELIVERY

被引:0
|
作者
Levin, Michael E. [1 ]
机构
[1] Univ Cape Town, Dept Paediat & Child Hlth, Div Allergy, Cape Town, South Africa
关键词
METERED-DOSE INHALER; DRUG-DELIVERY; CHILDREN; OUTCOMES; THERAPY; DEVICE; SPACER;
D O I
暂无
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Pressurised metered-dose inhalers (pMDIs), nebulisers and dry-powder inhalers (DPIs) aim to deliver aerosols to the lungs. With optimal technique, lung deposition ranges from below 10% to approximately 15%. pMDIs are the most frequently used device. Excellent hand-breath co-ordination is required for effective use of pMDIs. Optimal technique requires slow inspiratory flow of 30 l/min and a breath hold of 10 seconds. Deposition in crying infants is minimal. 'Blow-by therapy' of nebuliser or pMDI aerosol delivered close to the sleeping child's mouth and nose is ineffective. Spacers and valved holding chambers provide an additional volume in which medication is dispersed, before it is breathed into the lungs. DPIs overcome the difficulties of poor hand-breath co-ordination. Patients who are unable to generate sufficient inspiratory flow and depth of breathing to trigger DPIs should not use these devices. Patients must not exhale into the device prior to inspiration. Equivalent clinical results can be achieved from any delivery device, providing the patient can use it correctly. Selection of the appropriate device for each patient requires consideration of multiple factors. Inhaler technique should be demonstrated by the patient at each visit, assessed by the health-care provider, and where necessary, training to optimise aerosol delivery should be repeated.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [21] DELIVERY OF BIOTHERAPEUTICS BY INHALATION AEROSOL
    NIVEN, RW
    CRITICAL REVIEWS IN THERAPEUTIC DRUG CARRIER SYSTEMS, 1995, 12 (2-3): : 151 - 231
  • [22] Other medications for aerosol delivery
    Rubin, Bruce K.
    PAEDIATRIC RESPIRATORY REVIEWS, 2006, 7 : S76 - S79
  • [23] The AERX™ Aerosol Delivery System
    Jeff Schuster
    Reid Rubsamen
    Peter Lloyd
    Jack Lloyd
    Pharmaceutical Research, 1997, 14 : 354 - 357
  • [24] Effect of Aerosol Devices and Administration Techniques on Drug Delivery in a Simulated Spontaneously Breathing Pediatric Tracheostomy Model
    Alhamad, Bshayer R.
    Fink, James B.
    Harwood, Robert J.
    Sheard, Meryl M.
    Ari, Arzu
    RESPIRATORY CARE, 2015, 60 (07) : 1026 - 1032
  • [25] Aerosol delivery during invasive mechanical ventilation: a systematic review
    Dugernier, Jonathan
    Ehrmann, Stephan
    Sottiaux, Thierry
    Roeseler, Jean
    Wittebole, Xavier
    Dugernier, Thierry
    Jamar, Francois
    Laterre, Pierre-Francois
    Reychler, Gregory
    CRITICAL CARE, 2017, 21
  • [26] Face Mask Leak Determines Aerosol Delivery in Noninvasive Ventilation
    Haw, Alexandra
    McPeck, Michael
    Cuccia, Ann D.
    Smaldone, Gerald C.
    RESPIRATORY CARE, 2021, 66 (01) : 95 - 103
  • [27] A narrative review on trans-nasal pulmonary aerosol delivery
    Li, Jie
    Fink, James B.
    MacLoughlin, Ronan
    Dhand, Rajiv
    CRITICAL CARE, 2020, 24 (01):
  • [28] A new aerosol delivery approach for enhanced long-term respiratory care in resource-poor settings
    Khan, Mohammed Asad
    Gadgil, Hrishikesh
    Kumar, Sudarshan
    POWDER TECHNOLOGY, 2025, 449
  • [29] Optimal delivery of aerosolized medication to mechanically ventilated pediatric and neonatal patients: A scoping review
    Chartrand, Louise
    Ploszay, Victoria
    Tessier, Sebastien
    CANADIAN JOURNAL OF RESPIRATORY THERAPY, 2022, 58 (01): : 199 - 203
  • [30] Alternative propellant aerosol delivery systems
    Smyth, HDC
    Leach, CL
    CRITICAL REVIEWS IN THERAPEUTIC DRUG CARRIER SYSTEMS, 2005, 22 (06): : 493 - 534