OPTIMAL AEROSOL DELIVERY

被引:0
|
作者
Levin, Michael E. [1 ]
机构
[1] Univ Cape Town, Dept Paediat & Child Hlth, Div Allergy, Cape Town, South Africa
关键词
METERED-DOSE INHALER; DRUG-DELIVERY; CHILDREN; OUTCOMES; THERAPY; DEVICE; SPACER;
D O I
暂无
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Pressurised metered-dose inhalers (pMDIs), nebulisers and dry-powder inhalers (DPIs) aim to deliver aerosols to the lungs. With optimal technique, lung deposition ranges from below 10% to approximately 15%. pMDIs are the most frequently used device. Excellent hand-breath co-ordination is required for effective use of pMDIs. Optimal technique requires slow inspiratory flow of 30 l/min and a breath hold of 10 seconds. Deposition in crying infants is minimal. 'Blow-by therapy' of nebuliser or pMDI aerosol delivered close to the sleeping child's mouth and nose is ineffective. Spacers and valved holding chambers provide an additional volume in which medication is dispersed, before it is breathed into the lungs. DPIs overcome the difficulties of poor hand-breath co-ordination. Patients who are unable to generate sufficient inspiratory flow and depth of breathing to trigger DPIs should not use these devices. Patients must not exhale into the device prior to inspiration. Equivalent clinical results can be achieved from any delivery device, providing the patient can use it correctly. Selection of the appropriate device for each patient requires consideration of multiple factors. Inhaler technique should be demonstrated by the patient at each visit, assessed by the health-care provider, and where necessary, training to optimise aerosol delivery should be repeated.
引用
收藏
页码:27 / 30
页数:4
相关论文
共 50 条
  • [1] Novel Aerosol Delivery Devices
    Singh, Supriya
    Kanbar-Agha, Faisal
    Sharafkhaneh, Amir
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 36 (04) : 543 - 551
  • [2] In Vitro Performance of Spacers for Aerosol Delivery during Adult Mechanical Ventilation
    Boukhettala, Nabile
    Poree, Thierry
    Diot, Patrice
    Vecellio, Laurent
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2015, 28 (02) : 130 - 136
  • [3] In vitro evaluation of aerosol drug delivery with and without high flow nasal cannula in children
    Alalwan, Mahmood A.
    Fink, James B.
    Ari, Arzu
    PEDIATRIC PULMONOLOGY, 2019, 54 (12) : 1968 - 1973
  • [4] Survey of Aerosol Delivery Techniques to Spontaneously Breathing Tracheostomized Children
    Willis, L. Denise
    Berlinski, Ariel
    RESPIRATORY CARE, 2012, 57 (08) : 1234 - 1241
  • [5] Dos and don'ts to optimize transnasal aerosol drug delivery in clinical practice
    Ari, Arzu
    Hoops, Jordan A.
    Koyuncu, Ayfer
    Fink, James B.
    EXPERT OPINION ON DRUG DELIVERY, 2024, 21 (07) : 1103 - 1114
  • [6] Optimal Drug-Aerosol Delivery to Predetermined Lung Sites
    Kleinstreuer, Clement
    Zhang, Zhe
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (01):
  • [7] Aerosol delivery to intubated patients
    Fink, James
    Ari, Arzu
    EXPERT OPINION ON DRUG DELIVERY, 2013, 10 (08) : 1077 - 1093
  • [8] Workshop Report: Aerosol Delivery to Spontaneously Breathing Tracheostomized Patients
    Berlinski, Ariel
    Ari, Arzu
    Davies, Phil
    Fink, Jim
    Majaesic, Carina
    Reychler, Gregory
    Tatla, Taran
    Amirav, Israel
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2017, 30 (04) : 207 - 222
  • [9] Aerosol delivery via noninvasive ventilation: role of models and bioanalysis
    Saeed, Haitham
    Harb, Hadeer S.
    Madney, Yasmin M.
    Abdelrahim, Mohamed E. A.
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (07)
  • [10] Assessing of low-tech solutions for aerosol delivery: Comparative performance study of manufactured versus homemade spacers
    Moreau-Neidhardt, Manon
    Leclerc, Lara
    Grange, Jeanne
    Perinel, Sophie
    Pourchez, Jeremie
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2023, 633