Developments in hollow fiber based liquid-phase microextraction: principles and applications

被引:161
作者
Ghambarian, Mahnaz [2 ]
Yamini, Yadollah [1 ]
Esrafili, Ali [1 ]
机构
[1] Tarbiat Modares Univ, Fac Sci, Dept Chem, Tehran, Iran
[2] Iranian Res & Dev Ctr Chem Ind, ACECR, Tehran, Iran
关键词
Hollow fiber membrane; Liquid-phase microextraction; Sample preparation; Environmental and pharmaceutical applications; CHROMATOGRAPHY-MASS SPECTROMETRY; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; INJECTION-PORT-DERIVATIZATION; ENVIRONMENTAL WATER SAMPLES; MEMBRANE SOLVENT MICROEXTRACTION; SIMULTANEOUS BACK-EXTRACTION; IMMISCIBLE ORGANIC-SOLVENTS; CARRIER-MEDIATED TRANSPORT; SOLID-MATRIX LUMINESCENCE; DUAL GAUGE MICROSYRINGE;
D O I
10.1007/s00604-012-0773-x
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Hollow fiber liquid-phase microextraction (HF-LPME) offers an efficient alternative to classical techniques for sample preparation and preconcentration. Features include high selectivity, good enrichment factors, and improved possibilities for automation. HP-LPME relies on the extraction of target analytes from aqueous samples into a supported liquid membrane (SLM) sustained in the pores of the wall of a porous hollow fiber, and then into an acceptor phase (that can be aqueous or organic) in the lumen of the hollow fiber. After extraction, the acceptor solution is directly subjected to a chemical analysis. HP-LPME can be performed in either the 2- or 3-phases mode. In the 2-phase mode, the organic solvent is present both in the porous wall and inside the lumen of the hollow fiber. In the 3-phase mode, the acceptor phase can be aqueous and this results in a conventional 3-phase system compatible with HPLC or capillary electrophoresis. Alternatively, the acceptor solution is organic and this represents a 3-phase extraction system with two immiscible organic solvents that is compatible with all common analytical instruments. In HP-LPME methods based on the use of SLMs, the mass transfer occurs by passive diffusion, and high extraction yields as well as efficient extraction kinetics are obtained by applying a pH gradient. In addition, active transport can be performed by using carrier or applying an electrical potential across the SLM. Due to high analyte preconcentration, excellent sample clean-up, and low consumption of organic solvent, HF-LPME has a large application potential in areas such as drug analysis and environmental monitoring. This review focuses on the fundamentals of extraction principles, technical implementations, and future trends in HF-LPME.
引用
收藏
页码:271 / 294
页数:24
相关论文
共 134 条
[1]   Stereospecific determination of citalopram and desmethylcitalopram by capillary electrophoresis and liquid-phase microextraction [J].
Andersen, S ;
Halvorsen, TG ;
Pedersen-Bjergaard, S ;
Rasmussen, KE ;
Tanum, L ;
Refsum, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (02) :263-273
[2]   Liquid-phase microextraction combined with capillary electrophoresis, a promising tool for the determination of chiral drugs in biological matrices [J].
Andersen, S ;
Halvorsen, TG ;
Pedersen-Bjergaard, S ;
Rasmussen, KE .
JOURNAL OF CHROMATOGRAPHY A, 2002, 963 (1-2) :303-312
[3]   Electromembrane extraction of peptides [J].
Balchen, Marte ;
Reubsaet, Leon ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (02) :143-149
[4]   Electrokinetic migration of acidic drugs across a supported liquid membrane [J].
Balchen, Marte ;
Gjelstad, Astrid ;
Rasmussen, Knut Einar ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1152 (1-2) :220-225
[5]   Rapid isolation of angiotensin peptides from plasma by electromembrane extraction [J].
Balchen, Marte ;
Halvorsen, Trine Gronhaug ;
Reubsaet, Leon ;
Pedersen-Bjergaard, Stig .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (41) :6900-6905
[6]   Hollow fiber-liquid-phase microextraction of fungicides from orange juices [J].
Barahona, Francisco ;
Gjelstad, Astrid ;
Pedersen-Bjergaard, Stig ;
Rasmussen, Knut Einar .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (13) :1989-1994
[7]   Analysis of persistent organic pollutants in marine sediments using a novel microwave assisted solvent extraction and liquid-phase microextraction technique [J].
Basheer, C ;
Obbard, JP ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1068 (02) :221-228
[8]   Analysis of endocrine disrupting alkylphenols, chlorophenols and bisphenol-A using hollow fiber-protected liquid-phase microextraction coupled with injection port-derivatization gas chromatography-mass spectrometry [J].
Basheer, C ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1057 (1-2) :163-169
[9]   Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :161-169
[10]   Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry [J].
Basheer, C ;
Balasubramanian, R ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) :11-20