In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation?

被引:73
作者
Matthews, Iain G. [1 ]
Fazal, Iftikhar A. [2 ]
Bates, Matthew G. D. [3 ]
Turley, Andrew J. [2 ]
机构
[1] Freeman Rd Hosp, Dept Cardiol, Newcastle Upon Tyne NE7 7DN, Tyne & Wear, England
[2] James Cook Univ Hosp, Div Cardiothorac, Middlesbrough TS4 3BW, Cleveland, England
[3] Univ Newcastle, Mitochondrial Res Grp, Inst Ageing & Hlth, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
关键词
Aortic valve replacement; Permanent pacemaker; Outcome; Predictors; Conducting system disease; RISK-FACTORS; DEPENDENCY; SURGERY;
D O I
10.1510/icvts.2010.254607
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A best evidence topic in cardiac surgery was written according to a structured protocol. The question was to determine what preoperative, perioperative and postoperative factors influence the requirement for permanent pacemaker (PPM) implantation postisolated aortic valve replacement (AVR). Transcatheter aortic valve intervention was not included in this analysis. Using the reported search method outlined below, 705 papers were found. No randomised controlled trials, meta-analyses or registries were identified. Seven single-centre retrospective observational studies represent the best evidence on the subject. The author, journal, date and country of publication, level of evidence, patient group studied, study type, outcomes and results were tabulated. The incidence of PPM implantation following AVR varied from 3.0% to 11.8% (mean 7.0%, median 7.2%). Current best available evidence suggests that baseline evidence of conducting system disease - first degree atrioventricular block (AVB), left anterior hemiblock, right bundle branch block (RBBB) or left bundle branch block (LBBB) is the most powerful independent predictor of PPM requirement following AVR. Other important predictors are surgery for aortic regurgitation, preoperative myocardial infarction and longer perioperative cardiopulmonary bypass time. No consistent postoperative factors were identified. The mean time to PPM implant postAVR ranged from 6 to 13 days in the four studies that reported it. Current European Society of Cardiology guidelines recommend a period of seven days of persistent AVB postsurgery prior to PPM implantation. (C) 2011 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
引用
收藏
页码:475 / 479
页数:5
相关论文
共 15 条
[1]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.hrthm.2008.04.014, 10.1016/j.jacc.2008.05.007]
[2]   Permanent pacemaker implantation after isolated aortic valve replacement: Incidence, indications, and predictors [J].
Dawkins, Sam ;
Hobson, Alex R. ;
Kalra, Paul R. ;
Tang, Augustine T. M. ;
Monro, James L. ;
Dawkins, Keith D. .
ANNALS OF THORACIC SURGERY, 2008, 85 (01) :108-112
[3]  
Dunning Joel, 2003, Interact Cardiovasc Thorac Surg, V2, P405, DOI 10.1016/S1569-9293(03)00191-9
[4]   The bioprosthesis type and size influence the postoperative incidence of permanent pacemaker implantation in patients undergoing aortic valve surgery [J].
Elahi, Maqsood ;
Usmaan, Khalid .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 15 (02) :113-118
[5]   Risk factors for requirement of permanent pacemaker implantation after aortic valve replacement [J].
Erdogan, HB ;
Kayalar, N ;
Ardal, H ;
Omeroglu, SN ;
Kirali, K ;
Guler, M ;
Akinci, E ;
Yakut, C .
JOURNAL OF CARDIAC SURGERY, 2006, 21 (03) :211-215
[6]   Indications, effectiveness, and long-term dependency in permanent pacing after cardiac surgery [J].
Glikson, M ;
Dearani, JA ;
Hyberger, LK ;
Schaff, HV ;
Hammill, SC ;
Hayes, DL .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1309-1313
[7]   Permanent cardiac pacing after a cardiac operation: Predicting the use of permanent pacemakers [J].
Gordon, RS ;
Ivanov, J ;
Cohen, G ;
Ralph-Edwards, AL .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1698-1704
[8]   Permanent Pacemaker Implantation Following Aortic Valve Replacement: Current Prevalence and Clinical Predictors [J].
Huynh, Hieu ;
Dalloul, Ghassan ;
Ghanbari, Hamid ;
Burke, Peter ;
David, Mariam ;
Daccarett, Marcos ;
Machado, Christian ;
David, Shukri .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2009, 32 (12) :1520-1525
[9]   Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery [J].
Koplan, BA ;
Stevenson, WG ;
Epstein, LM ;
Aranki, SF ;
Maisel, WH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (05) :795-801
[10]   Risk factors for pacemaker implantation following aortic valve replacement:: a single centre experience [J].
Limongelli, G ;
Ducceschi, V ;
D'Andrea, A ;
Renzulli, A ;
Sarubbi, B ;
De Feo, M ;
Cerasuolo, F ;
Calabrò, R ;
Cotrufo, M .
HEART, 2003, 89 (08) :901-904