A frequency domain compensation scheme for multi-slice helical CT reconstruction with tilted gantry

被引:1
|
作者
Hsieh, J [1 ]
Hu, H [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
来源
MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3 | 2001年 / 4322卷
关键词
multi-slice computed tomography; tilted helical scan; tomographic reconstruction; image artifact;
D O I
10.1117/12.430998
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Multi-slice CT (MCT) is one of the most recent technical advancements in computed tomography. MCT offers high volume coverage, faster scan speed, and reduced x-ray tube loading. When combined with the helical scan mode, MCT provides even higher volume coverage as a result of the elimination of the inter-scan delays. Similar to the single slice CT, the projection data collected in MCT is inherently inconsistent.. To combat projection inconsistency, many image reconstruction algorithms were investigated and developed. Recent studies, have shown, however, that the image quality of MCT can be significantly degraded when the data is collected in a tilted helical mode. The degradation can be so severe that it is unacceptable for routine clinical usage. In this paper, we present a detailed investigation to, show that the root cause of the image quality degradation is the deviation of the reconstruction iso-center from the gantry iso-center. An analytical model is derived to establish a quantitative relationship between the iso-center shift and other system parameters. The model serves as the mathematical basis for the derivation of a frequency-domain correction algorithm. Detailed performance evaluation is provided in terms of spatial resolution, noise, computational efficiency, and image artifacts.
引用
收藏
页码:105 / 112
页数:4
相关论文
共 18 条
  • [11] Otosclerosis: Anatomy and Pathology in the Temporal Bone Assessed by Multi-Slice and Cone-Beam CT
    Redfors, Ylva Dahlin
    Grondahl, Hans Goran
    Hellgren, Johan
    Lindfors, Ninita
    Nilsson, Inger
    Moller, Claes
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 922 - 927
  • [12] Cone-angle dependent generalized weighting scheme for 16-slice helical CT
    Hsieh, J
    Dong, YT
    Simoni, P
    Toth, T
    Slack, CL
    Grekowicz, B
    Seidenschnur, G
    Shaughnessy, C
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 74 - 81
  • [13] Cone-Beam CT Compared to Multi-Slice CT for the Diagnostic Analysis of Conductive Hearing Loss: A Feasibility Study
    Kemp, Pieter
    Van Stralen, Jiska
    De Graaf, Pim
    Berkhout, Erwin
    Van Horssen, Pepijn
    Merkus, Paul
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2020, 16 (02) : 222 - +
  • [14] New aspects in the emergency room management of critically injured patients: A multi-slice CT-oriented care algorithm
    Hilbert, P.
    Nieden, K. zur
    Hofmann, G. O.
    Hoeller, I.
    Koch, R.
    Stuttmann, R.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (05): : 552 - 558
  • [15] Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery
    Nicolielo, Laura Ferreira Pinheiro
    Van Dessel, Jeroen
    Shaheen, Eman
    Letelier, Carolina
    Codari, Marina
    Politis, Constantinus
    Lambrichts, Ivo
    Jacobs, Reinhilde
    INTERNATIONAL JOURNAL OF ORAL SCIENCE, 2017, 9 (03) : 139 - 144
  • [16] Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery
    Laura Ferreira Pinheiro Nicolielo
    Jeroen Van Dessel
    Eman Shaheen
    Carolina Letelier
    Marina Codari
    Constantinus Politis
    Ivo Lambrichts
    Reinhilde Jacobs
    International Journal of Oral Science, 2017, 9 : 139 - 144
  • [17] Validation of a novel imaging approach using multi-slice CT and cone-beam CT to follow-up on condylar remodeling after bimaxillary surgery
    Laura Ferreira Pinheiro Nicolielo
    Jeroen Van Dessel
    Eman Shaheen
    Carolina Letelier
    Marina Codari
    Constantinus Politis
    Ivo Lambrichts
    Reinhilde Jacobs
    International Journal of Oral Science, 2017, 9 (03) : 139 - 144
  • [18] Multi-slice CT (MSCT) imaging in pretrans-catheter aortic valve implantation (TAVI) screening. How to perform and how to interpret
    Latsios, George
    Spyridopoulos, Themistoklis N.
    Toutouzas, Konstantinos
    Synetos, Andreas
    Trantalis, George
    Stathogiannis, Konstantinos
    Penesopoulou, Vassiliki
    Oikonomou, George
    Brountzos, Elias
    Tousoulis, Dimitrios
    HELLENIC JOURNAL OF CARDIOLOGY, 2018, 59 (01) : 3 - 7