Multi-slice CT (MCT) is one of the most recent technical advancements in computed tomography. MCT offers high volume coverage, faster scan speed, and reduced x-ray tube loading. When combined with the helical scan mode, MCT provides even higher volume coverage as a result of the elimination of the inter-scan delays. Similar to the single slice CT, the projection data collected in MCT is inherently inconsistent.. To combat projection inconsistency, many image reconstruction algorithms were investigated and developed. Recent studies, have shown, however, that the image quality of MCT can be significantly degraded when the data is collected in a tilted helical mode. The degradation can be so severe that it is unacceptable for routine clinical usage. In this paper, we present a detailed investigation to, show that the root cause of the image quality degradation is the deviation of the reconstruction iso-center from the gantry iso-center. An analytical model is derived to establish a quantitative relationship between the iso-center shift and other system parameters. The model serves as the mathematical basis for the derivation of a frequency-domain correction algorithm. Detailed performance evaluation is provided in terms of spatial resolution, noise, computational efficiency, and image artifacts.
引用
收藏
页码:105 / 112
页数:4
相关论文
共 18 条
  • [1] Improvement of Efficiency and Flexibility in Multi-slice Helical CT
    孙文武
    陈思平
    庄天戈
    JournalofShanghaiJiaotongUniversity(Science), 2008, (04) : 408 - 412
  • [2] Improvement of efficiency and flexibility in multi-slice helical CT
    Sun W.-W.
    Chen S.-P.
    Zhuang T.-G.
    J. Shanghai Jiaotong Univ. Sci., 2008, 4 (408-412): : 408 - 412
  • [3] Analytical models for multi-slice helical CT performance parameters
    Hsieh, J
    MEDICAL PHYSICS, 2003, 30 (02) : 169 - 178
  • [4] Analytical noise and slice-sensitivity-profile models for multi-slice helical CT
    Hsieh, J
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 112 - 119
  • [5] Multi-slice Tomographic Reconstruction: To Couple or Not to Couple
    Gopal, Preeti
    Chandran, Sharat
    Svalbe, Imants
    Rajwade, Ajit
    TENTH INDIAN CONFERENCE ON COMPUTER VISION, GRAPHICS AND IMAGE PROCESSING (ICVGIP 2016), 2016,
  • [6] Clinical use of multi-slice CT coronary angiography
    Achenbach, S
    HERZ, 2003, 28 (02) : 119 - 125
  • [7] Performance of approximate cone-beam reconstruction in multi-slice computed tomography
    Bruder, H
    Kachelriess, M
    Schaller, S
    Mertelmeier, T
    MEDICAL IMAGING 2000: IMAGE PROCESSING, PTS 1 AND 2, 2000, 3979 : 541 - 553
  • [8] Usefulness of Multi-slice CT in a Case with Internal Fistulas in Crohn's Disease
    Oshima, Go
    Itano, Osamu
    Matsui, Hideo
    Chiba, Naokazu
    Ishikawa, Hideki
    Koyama, Yasumasa
    Miyakita, Makoto
    Yuasa, Yuji
    HEPATO-GASTROENTEROLOGY, 2008, 55 (86-87) : 1664 - 1665
  • [9] Klinischer Stellenwert der Cardio-CT-KoronarangiographieClinical Use of Multi-Slice CT Coronary Angiography
    Stephan Achenbach
    Herz, 2003, 28 (2) : 119 - 125
  • [10] Multi-Slice CT Angiography in Acute Suspected Mesenteric Ischemia: Role in Diagnosis and Differential Diagnosis
    Cao, Xueyuan
    Jiang, Jing
    Wang, Jing-Yu
    Suo, Jian
    Wang, Jing
    2013 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING (CME), 2013, : 467 - 470