Speed of Sound Imaging Improved Image Quality in Breast Sonography

被引:12
作者
Barr, Richard G. [1 ,2 ]
Rim, Alice [3 ]
Graham, Ruffin [3 ]
Berg, Wendie
Grajo, Joseph R. [1 ,4 ]
机构
[1] Northeastern Ohio Univ Coll Med & Pharm, Coll Med, Rootstown, OH 44272 USA
[2] Radiol Consultants Inc, Youngstown, OH USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Amer Radiol Serv Inc, Johns Hopkins Green Spring, Lutherville Timonium, MD USA
关键词
speed of sound imaging; breast; image quality;
D O I
10.1097/RUQ.0b013e3181b789aa
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to evaluate blindly breast ultrasound images corrected for the speed of sound in breast tissue compared with conventional images. Materials and Methods: In this study, 409 images from 153 patients were obtained on an Antares Ultrasound system. The system was modified to process the radiofrequency data with the standard 1540 m/s as the speed of sound and at a corrected speed of sound for breast tissue. An offline MATLAB-developed program randomized the image pairs, and 3 blinded reviewers who were unaware of the new technique reviewed these. The reviewers were asked to rate the image quality of the pair on a 5-point scale (right++, right+, equal, left+, left++). Comments on differences in the images were also recorded. Results: Conventional images were graded much better in 0.0% and better: in 15.1% +/- 6.2%. Corrected speed of sound images were rated much better in 10.5% +/- 14.3%, better in 48.4% +/- 14.3%, and equal in 25.9% +/- 27.6%. Improvements in image quality with corrected speed of sound images included better margin characterization and improved resolution of calcifications. Conclusions: Correcting for the speed of sound in breast ultrasound improved the overall image quality in 59% of cases, whereas 26% were of similar quality. Specific improvements noted included better characterization of mass margins, tissue interfaces, and depiction of calcifications.
引用
收藏
页码:141 / 144
页数:4
相关论文
共 5 条
[1]   The direct estimation of sound speed using pulse-echo ultrasound [J].
Anderson, ME ;
Trahey, GE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (05) :3099-3106
[2]   The impact of sound speed errors on medical ultrasound imaging [J].
Anderson, ME ;
McKeag, MS ;
Trahey, GE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2000, 107 (06) :3540-3548
[3]   Simulation study of effects of speed of sound and attenuation on ultrasound lateral resolution [J].
Chen, Q ;
Zagzebski, JA .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (10) :1297-1306
[4]   COMPREHENSIVE COMPILATION OF EMPIRICAL ULTRASONIC PROPERTIES OF MAMMALIAN-TISSUES [J].
GOSS, SA ;
JOHNSTON, RL ;
DUNN, F .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1978, 64 (02) :423-457
[5]   Sound speed correction in ultrasound imaging [J].
Napolitano, David ;
Chou, Ching-Hua ;
McLaughlin, Glen ;
Ji, Ting-Lan ;
Mo, Larry ;
DeBusschere, Derek ;
Steins, Robert .
ULTRASONICS, 2006, 44 (SUPPL.) :E43-E46