Comparison of performance of solar photovoltaics on dual axis tracker with fixed axis at 13°N latitude

被引:0
作者
Rao, Roshan R. [1 ]
Swetha, H. R. [1 ]
Srinivasan, J. [1 ]
Ramasesha, Sheela K. [1 ]
机构
[1] Indian Inst Sci, Divecha Ctr Climate Change, Bengaluru 560012, Karnataka, India
来源
CURRENT SCIENCE | 2015年 / 108卷 / 11期
关键词
Cost payback time; dual axis Sun tracker; energy conversion; solar panel;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Tracking systems, that continually orient photovoltaic (PV) panels towards the Sun, are expected to increase the power output from the PV panels. Tremendous amount of research is being done and funds are being spent in order to increase the efficiency of PV cells to generate more power. We report the performance of two almost identical PV systems; one at a fixed latitude tilt and the other on a two-axis tracker. We observed that the fixed axis PV panels generated 336.3 kWh, and the dual-axis Sun-tracked PV panels generated 407.2 kWh during August 2012 March 2013. The tracked panels generated 21.2% more electricity than the optimum tilt angle fixed-axis panels. The cost payback calculations indicate that the additional cost of the tracker can be recovered in 450 days.
引用
收藏
页码:2087 / 2094
页数:8
相关论文
共 14 条
  • [1] Ahmad M.J., 2009, Open Renewable Energy Journal, V2, P19
  • [2] [Anonymous], 1998, IEC 61724
  • [3] [Anonymous], GLOB STAT REP
  • [4] [Anonymous], NREL SYST ADV MOD SA
  • [5] Briner G., 2009, THESIS IMPERIAL COLL
  • [6] Duffle JA., 2006, Solar engineering of thermal processes, V3rd
  • [7] Tracking benefits for solar collectors installed in Bangalore
    Fahl, Pascal
    Ganapathisubbu, S.
    [J]. JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2011, 3 (02)
  • [8] Green M.A., 1982, Solar Cells: Operating Principles, Technology, and System Applications
  • [9] Helwa N. H., 2000, ENERG SOURCE, V22, p[1, 2]
  • [10] Kivrak S., 2012, PRZEGLAD ELEKTROTECH