Use of a novel platelet function analyzer (PFA-100™) with high sensitivity to disturbances in von willebrand factor to screen for von Willebrand's disease and other disorders

被引:0
|
作者
Favaloro, EJ [1 ]
Facey, D [1 ]
Henniker, A [1 ]
机构
[1] Westmead Hosp, Western Sydney Area Hlth Serv, Inst Clin Pathol & Med Res, Dept Haematol,Diagnost Hemostasis Lab, Westmead, NSW 2145, Australia
关键词
von Willebrand factor; von Willebrand's disease; laboratory assessment; screening; diagnosis;
D O I
10.1002/(SICI)1096-8652(199911)62:3<165::AID-AJH6>3.0.CO;2-C
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The PFA-100(TM) is a platelet function analyzer which uses whole blood and high shear stress blood flow to simulate primary hemostasis and assess platelet function. A small volume of blood is introduced into a disposable cartridge, and forced through a capillary tube, Platelet adhesion and aggregation is then initiated following exposure to either collagen/ADP [C/ADP] or collagen/epinephrine [C/Epi] coated membranes. Movement of blood through the capillary, and its subsequent occlusion is monitored and yields the measured endpoint (closure time [CT] in seconds). Using two approaches, we assessed the sensitivity of this system to disturbances in the function of von Willebrand Factor (VWF), Firstly, we assessed the ability of the PFA-100(TM) to detect the presence of von Willebrands Disease (VWD), Using normal individuals (N=18), CTs (in seconds; mean [range = mean +/- 2SD]) were (i) C/ADP, 95 [66-124], (ii) C/Epi, 128 [98-158]. A panel of 47 patients undergoing evaluation for clinical hemostatic defects inclusive of VWD were also evaluated. All samples from patients confirmed to have VWD following specific VWF studies [N = 9; 3 x Type 1, 1 x Type 3, 1 x Type 2A, 4 x Type 2B] gave prolonged CTs (greater than or equal to 200 s) for both C/ADP and C/Epi membranes; in contrast, all patients yielding normal CT values were found to yield normal VWF results (i.e., were found not to suffer from VWD), Patients with hemophilia (1 x hemophilia A, 1 x hemophilia C) gave normal PFA-100(TM) CT, while those with clinical thrombocytopaenia (N = 3) gave prolonged PFA-100(TM) CT. A number of other patient samples also gave abnormal CT values which in some cases could be linked to recent aspirin consumption, In the second evaluation process, and using normal blood, we have assessed the ability of various antibodies to influence the CT. Of the monoclonal antibody panel tested [N = 20], only a proportion of those against VWF [6/10] or gp1b/lX [CD42; 2/5] were found to be inhibitory (i.e., prolonged the CT), Data using polyclonal antibodies (against platelets, VWF, fibrinogen and fibronectin) is more complex but largely confirms the sensitivity of the system to VWF. On the basis of these results, we conclude that the PFA-100(TM) is highly sensitive to disturbances in VWF and to the presence of VWD and may thus provide a valuable screening test for VWD in certain specific circumstances (i.e., acute need conditions or remote testing sites; normal CT result generally effective as negative predictor, i.e. not severe VWD), However, since abnormal CT values were obtained in clinical situations other than evident VWD, the PFA-100(TM) cannot be used as a specific diagnostic tool to establish the presence of VWD. Thus, any abnormal PFA-100TM CT result should be thoroughly evaluated by follow-up specific testing to establish the true clinical disorder affecting the individual under investigation, inclusive of appropriate VWF assays if VWD is clinically suspected. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 33 条
  • [21] Platelet Adhesion Mediated by von Willebrand Factor at High Shear Rates Is Associated with Premature Coronary Artery Disease
    Okhota, Sergey
    Kozlov, Sergey
    Avtaeva, Yuliya
    Melnikov, Ivan
    Saburova, Olga
    Guria, Konstantin
    Matroze, Evgeny
    Gabbasov, Zufar
    BIOMEDICINES, 2023, 11 (07)
  • [22] Clinical use of Haemate® P in inherited von Willebrand's disease: a cohort study on 100 Italian patients
    Federici, Augusto B.
    Castaman, Giancarlo
    Franchini, Massimo
    Morfini, Massimo
    Zanon, Ezio
    Coppola, Antonio
    Tagliaferri, Annarita
    Boeri, Elio
    Mazzucconi, Maria Gabriella
    Rossetti, Gina
    Mannucci, Pier Mannuccio
    HAEMATOLOGICA, 2007, 92 (07) : 944 - 951
  • [23] Successful Use of a Highly Purified Plasma von Willebrand Factor Concentrate Containing Little FVIII for the Long-Term Prophylaxis of Severe (Type 3) von Willebrand's Disease
    Simurda, Tomas
    Dobrotova, Miroslava
    Skornova, Ingrid
    Sokol, Juraj
    Kubisz, Peter
    Stasko, Jan
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2017, 43 (06) : 639 - 641
  • [24] Influence of ABO Locus on PFA-100 Collagen-ADP Closure Time Is Not Totally Dependent on the Von Willebrand Factor. Results of a GWAS on GAIT-2 Project Phenotypes
    Pujol-Moix, Nuria
    Martinez-Perez, Angel
    Sabater-Lleal, Maria
    Llobet, Dolors
    Vilalta, Noelia
    Hamsten, Anders
    Carles Souto, Joan
    Manuel Soria, Jose
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (13):
  • [25] The power of a standardized bleeding score in diagnosing paediatric type 1 von Willebrand's disease and platelet function defects
    Marcus, P. D.
    Nire, K. G.
    Grooms, L.
    Klima, J.
    O'Brien, S. H.
    HAEMOPHILIA, 2011, 17 (02) : 223 - 227
  • [26] Von Willebrand's disease: a novel mutation, P1824H and the incidence of R1205H defect among families with dominant quantitative von Willebrand factor deficiency
    Casana, Pilar
    Cabrera, Noelia
    Haya, Saturnino
    Rosa Cid, Ana
    Antonio Aznar, Jose
    HAEMATOLOGICA, 2006, 91 (08) : 1130 - 1133
  • [27] Influence of platelet count, acetylsalicylic acid, von Willebrand's disease, coagulopathies, and haematocrit on results obtained using a platelet function analyser in dogs
    Mischke, R
    Keidel, A
    VETERINARY JOURNAL, 2003, 165 (01) : 43 - 52
  • [28] A new case of platelet-type von Willebrand disease supports the recent findings of gain-of-function GP1BA variants outside the C-terminal disulphide loop enhances affinity for von Willebrand factor
    Monteiro, Catarina
    Goncalves, Ana
    Pereira, Monica
    Lau, Catarina
    Morais, Sara
    Santos, Rosario
    BRITISH JOURNAL OF HAEMATOLOGY, 2023, 203 (04) : 673 - 677
  • [30] No von Willebrand factor domains other than A1 are involved in type 2B von Willebrand disease: what the p.R924Q and p.A2178S variants teach us
    Casonato, Alessandra
    Gianesello, Lisa
    Regazzo, Daniela
    Galletta, Eva
    Daidone, Viviana
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2023, 7 (06)