Application of the evaporative light scattering detector to analytical problems in polymer science

被引:51
|
作者
Arndt, J. H. [1 ]
Macko, T. [1 ]
Bruell, R. [1 ]
机构
[1] Fraunhofer Inst Struct Durabil & Syst Reliabil, Div Plast, Grp Mat Analyt, D-64289 Darmstadt, Germany
关键词
Evaporative light scattering detector; Synthetic polymers; PERFORMANCE LIQUID-CHROMATOGRAPHY; SIZE-EXCLUSION CHROMATOGRAPHY; CHEMICAL-COMPOSITION DISTRIBUTION; THERMODYNAMICALLY GOOD SOLVENTS; ETHYLENE-PROPYLENE COPOLYMERS; FULL ADSORPTION MECHANISMS; TEMPERATURE GRADIENT HPLC; FATTY ALCOHOL ETHOXYLATES; CHARGED AEROSOL DETECTOR; FIELD-FLOW FRACTIONATION;
D O I
10.1016/j.chroma.2013.08.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last two decades the evaporative light scattering detector (ELSD) has found more and more use in liquid chromatography (LC) of synthetic polymers. The reason behind this is that it can be used for a significantly wider variety of analyte/solvent combinations. Although in many of the applications the ELSD has been used in a qualitative manner, it can also be used quantitatively. For quantitative interpretation of analyses it is, in the case of synthetic polymers, essential to know how parameters, which characterize a polymer sample (i.e., molar mass and chemical composition), as well as parameters, which are a consequence of the LC separation (i.e., composition and flow rate of the mobile phase, its composition), influence the response of the ELSD. This review gives a tabulated overview over applications of ELS detectors in polymer analysis. The influence of parameters arising from either the polymer side or the chromatographic separation is discussed in detail and, in addition, the influence of the ELS detector's running conditions, i.e. type and flow rate of gas and temperature of nebulizer and evaporator), will be reviewed. This information will prove valuable whenever the calibration of an ELSD for the quantitative analysis of synthetic polymers is attempted. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [41] Determination of residual poly diallyldimethylammonium chloride (pDADMAC) in monoclonal antibody formulations by size exclusion chromatography and evaporative light scattering detector
    Khodadadian, Mehdi
    Ghassemi, Maryam
    Behrouz, Hossein
    Maleknia, Shayan
    Mahboudi, Fereidoun
    BIOLOGICALS, 2019, 57 : 21 - 28
  • [42] Binary HPLC-Diode Array Detector and HPLC-Evaporative Light-Scattering Detector Fingerprints of Methanol Extracts from the Selected Sage (Salvia) Species
    Sajewicz, Mieczyslaw
    Staszek, Dorota
    Wojtal, Lukasz
    Kowalska, Teresa
    Hajnos, Michal L.
    Waksmundzka-Hajnos, Monika
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (01) : 71 - 76
  • [43] Simultaneous analysis of isoflavones and saponins in Pueraria flowers using HPLC coupled to an evaporative light scattering detector and isolation of a new isoflavone diglucoside
    Niiho, Yujiro
    Nakajima, Yoshijiro
    Yamazaki, Takashi
    Okamoto, Mitsuru
    Tsuchihashi, Ryota
    Kodera, Mitsuru
    Kinjo, Junei
    Nohara, Toshihiro
    JOURNAL OF NATURAL MEDICINES, 2010, 64 (03) : 313 - 320
  • [44] Separation and quantitation of bile acids using an isocratic solvent system for high performance liquid chromatography coupled to an evaporative light scattering detector
    Torchia, EC
    Labonté, ED
    Agellon, LB
    ANALYTICAL BIOCHEMISTRY, 2001, 298 (02) : 293 - 298
  • [45] Simultaneous analysis of isoflavones and saponins in Pueraria flowers using HPLC coupled to an evaporative light scattering detector and isolation of a new isoflavone diglucoside
    Yujiro Niiho
    Yoshijiro Nakajima
    Takashi Yamazaki
    Mitsuru Okamoto
    Ryota Tsuchihashi
    Mitsuru Kodera
    Junei Kinjo
    Toshihiro Nohara
    Journal of Natural Medicines, 2010, 64 : 313 - 320
  • [46] A direct method for the separation and quantification of bile acid acyl glycosides by high-performance liquid chromatography with an evaporative light scattering detector
    Kakiyama, Genta
    Hosoda, Atsuko
    Iida, Takashi
    Fujimoto, Yasuo
    Goto, Takaaki
    Mano, Nariyasu
    Goto, Junichi
    Nambara, Toshio
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1125 (01) : 112 - 116
  • [47] MEASUREMENT OF EVAPORATIVE LIGHT-SCATTERING OF MICROPARTICLES IN GASEOUS-PHASE
    DREUX, M
    LAFOSSE, M
    ANALUSIS, 1992, 20 (10) : 587 - 595
  • [48] Analysis of gemcitabine liposome injection by HPLC with evaporative light scattering detection
    Zhou, Qinmei
    Liu, Liucheng
    Zhang, Dengshan
    Fan, XingFeng
    JOURNAL OF LIPOSOME RESEARCH, 2012, 22 (04) : 263 - 269
  • [49] DETERMINATION OF ADDITIVES IN GASOLINE BY SEC COUPLED TO A LIGHT-SCATTERING DETECTOR-CHEMOMETRICS APPLICATION
    COLAIOCCO, S
    LATTANZIO, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1995, 18 (06): : 387 - 388
  • [50] In Vitro Plasma Protein Binding Determination of Lefamulin by Equilibrium Dialysis and High-Performance Liquid Chromatography Coupled With Evaporative Light Scattering Detector
    Xin, Lin
    Xiao, Hong-Liang
    Li, Mei-Di
    Ji, Yi-Kuan
    Liu, Wen-Zi
    Liao, Xiao-Ping
    Yu, Yang
    Zhao, Dong-Hao
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (04)