Application of the evaporative light scattering detector to analytical problems in polymer science

被引:51
|
作者
Arndt, J. H. [1 ]
Macko, T. [1 ]
Bruell, R. [1 ]
机构
[1] Fraunhofer Inst Struct Durabil & Syst Reliabil, Div Plast, Grp Mat Analyt, D-64289 Darmstadt, Germany
关键词
Evaporative light scattering detector; Synthetic polymers; PERFORMANCE LIQUID-CHROMATOGRAPHY; SIZE-EXCLUSION CHROMATOGRAPHY; CHEMICAL-COMPOSITION DISTRIBUTION; THERMODYNAMICALLY GOOD SOLVENTS; ETHYLENE-PROPYLENE COPOLYMERS; FULL ADSORPTION MECHANISMS; TEMPERATURE GRADIENT HPLC; FATTY ALCOHOL ETHOXYLATES; CHARGED AEROSOL DETECTOR; FIELD-FLOW FRACTIONATION;
D O I
10.1016/j.chroma.2013.08.041
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Over the last two decades the evaporative light scattering detector (ELSD) has found more and more use in liquid chromatography (LC) of synthetic polymers. The reason behind this is that it can be used for a significantly wider variety of analyte/solvent combinations. Although in many of the applications the ELSD has been used in a qualitative manner, it can also be used quantitatively. For quantitative interpretation of analyses it is, in the case of synthetic polymers, essential to know how parameters, which characterize a polymer sample (i.e., molar mass and chemical composition), as well as parameters, which are a consequence of the LC separation (i.e., composition and flow rate of the mobile phase, its composition), influence the response of the ELSD. This review gives a tabulated overview over applications of ELS detectors in polymer analysis. The influence of parameters arising from either the polymer side or the chromatographic separation is discussed in detail and, in addition, the influence of the ELS detector's running conditions, i.e. type and flow rate of gas and temperature of nebulizer and evaporator), will be reviewed. This information will prove valuable whenever the calibration of an ELSD for the quantitative analysis of synthetic polymers is attempted. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [1] THE APPLICATION OF AN EVAPORATIVE LIGHT-SCATTERING DETECTOR IN POLYMER ANALYSIS
    SCHULTZ, R
    ENGELHARDT, H
    CHROMATOGRAPHIA, 1990, 29 (11-12) : 517 - 522
  • [2] On the Issue of Characteristic Evaporative Light Scattering Detector Response
    Mojsiewicz-Pienkowska, Krystyna
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2009, 39 (02) : 89 - 94
  • [3] HPLC Analysis of Egg Yolk Phosphatidylcholine by Evaporative Light Scattering Detector
    Zhou Jing
    Hu Xianmei
    Wang Tianxin
    Liang Hao
    Yuan Qipeng
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2012, 20 (04) : 665 - 672
  • [4] Development and Evaluation of Micro Evaporative Light Scattering Detector
    Wang Yu-Hong
    Liu Fang
    Zhao Hui
    Wang Jian-Min
    Wang Yan
    Yan Chao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (10) : 1622 - 1626
  • [5] Analysis of silica nanoparticles by capillary electrophoresis coupled to an evaporative light scattering detector
    Adelantado, Carlos
    Rodriguez-Farinas, Nuria
    Rodriguez Martin-Doimeadios, Rosa C.
    Zougagh, Mohammed
    Rios, Angel
    ANALYTICA CHIMICA ACTA, 2016, 923 : 82 - 88
  • [6] Fast separation of triterpenoids by supercritical fluid chromatography/evaporative light scattering detector
    Lesellier, E.
    Destandau, E.
    Grigoras, C.
    Fougere, L.
    Elfakir, C.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1268 : 157 - 165
  • [7] EVAPORATIVE LIGHT-SCATTERING DETECTOR FOR ANALYSIS OF NATURAL PRODUCTS
    Morais Urano, Raquel P.
    Rodrigues, Fabiana T.
    Berlinck, Roberto G. S.
    QUIMICA NOVA, 2012, 35 (06): : 1198 - 1208
  • [8] Determination of biogenic amines in different cheese samples by LC with evaporative light scattering detector
    Spizzirri, U. Gianfranco
    Restuccia, Donatella
    Curcio, Manuela
    Parisi, Ortensia I.
    Iemma, Francesca
    Picci, Nevio
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2013, 29 (01) : 43 - 51
  • [9] A new method for the determination of biogenic amines in cheese by LC with evaporative light scattering detector
    Restuccia, Donatella
    Spizzirri, U. Gianfranco
    Puoci, Francesco
    Cirillo, Giuseppe
    Curcio, Manuela
    Parisi, Ortensia I.
    Iemma, Francesca
    Picci, Nevio
    TALANTA, 2011, 85 (01) : 363 - 369
  • [10] Usefulness of the evaporative light scattering detector for direct screening of biological fluids
    Criado, A
    Cárdenas, S
    Gallego, M
    Valcárcel, M
    ANALYTICA CHIMICA ACTA, 2001, 435 (02) : 281 - 288