Lung texture in serial thoracic CT scans: Registration- based methods to compare anatomically matched regions

被引:18
作者
Cunliffe, Alexandra R. [1 ]
Armato, Samuel G., III [1 ]
Fei, Xianhan M. [1 ]
Tuohy, Rachel E. [1 ]
Al-Hallaq, Hania A. [2 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL 60637 USA
基金
美国国家科学基金会;
关键词
texture analysis; deformable image registration; lung; CT; COMPUTER-AIDED DIAGNOSIS; DISEASE; CANCER;
D O I
10.1118/1.4805110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of this study was to compare three demons registration-based methods to identify spatially matched regions in serial computed tomography (CT) scans for use in texture analysis. Methods: Two thoracic CT scans containing no lung abnormalities and acquired during serial examinations separated by at least one week were retrospectively collected from 27 patients. Over 1000 regions of interest (ROIs) were randomly placed in the lungs of each baseline scan. Anatomically matched ROIs in the corresponding follow-up scan were placed by mapping the baseline scan ROI center pixel to (1) the original follow-up scan, (2) the follow-up scan resampled to match the baseline scan voxel size, and (3) the follow-up scan aligned to the baseline scan through affine registration. Mappings used the vector field obtained through demons deformable registration of each follow-up scan variant to the baseline scan. 140 texture features distributed among five feature classes were calculated in all ROIs. Feature value differences between paired ROIs were evaluated using Bland-Altman 95% limits of agreement. For each feature, (1) the mean feature value change and (2) the difference between the upper and lower limits of agreement were normalized to the mean feature value to obtain, respectively, the normalized bias and normalized range of agreement (nRoA). Nonparametric tests were used to evaluate differences in normalized bias and nRoA across the three methods. Results: Because patient CT scans contained no pathology, minimal changes in feature values were expected (i.e., low nRoA and normalized bias). Seventy-five features with very large feature value variability (nRoA >= 100%) were excluded from further analysis. Across the remaining 65 features, significant differences in normalized bias were observed among the three methods. The lowest normalized bias (median: 0.06%) was achieved when feature values were calculated on original follow-up scans. The affine registration method achieved the lowest nRoA, though nRoA was not significantly increased using original follow-up scans. Features with low nRoA values also had low normalized bias, though the converse was not necessarily true. Using nRoA as a metric, a set of 20 features having both low nRoA and normalized bias were identified. Conclusions: Three methods to facilitate texture analysis of serial CT scans using demons registration for ROI placement were evaluated. The bias in feature value change between matched ROIs was minimized when feature values were calculated on original baseline and follow-up scans. A set of features that had both low bias and variability (nRoA) in feature value change using this method were identified. This texture analysis approach could facilitate future measurement of pathologic changes between CT scans without necessitating calculation of feature values on deformed scans. c 2013 American Association of Physicists in Medicine.
引用
收藏
页数:9
相关论文
共 13 条
  • [1] Lung texture in serial thoracic CT scans: Assessment of change introduced by image registration
    Cunliffe, Alexandra R.
    Al-Hallaq, Hania A.
    Labby, Zacariah E.
    Pelizzari, Charles A.
    Straus, Christopher
    Sensakovic, William F.
    Ludwig, Michelle
    Armato, Samuel G., III
    MEDICAL PHYSICS, 2012, 39 (08) : 4679 - 4690
  • [2] Comparison of demons deformable registration-based methods for texture analysis of serial thoracic CT scans
    Cunliffe, Alexandra R.
    Al-Hallaq, Hania A.
    Fei, Xianhan M.
    Tuohy, Rachel E.
    Armato, Samuel G., III
    MEDICAL IMAGING 2013: COMPUTER-AIDED DIAGNOSIS, 2013, 8670
  • [3] Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy
    Cunliffe, Alexandra R.
    Armato, Samuel G., III
    Straus, Christopher
    Malik, Renuka
    Al-Hallaq, Hania A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) : 5387 - 5398
  • [4] SCreg: a registration-based platform to compare unicondylar knee arthroplasty SPECT/CT scans
    Dandois, Felix
    De Buck, Stijn
    Beckers, Lucas
    Shah, Darshan
    Slane, Laura
    Vandenneucker, Hilde
    Scheys, Lennart
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [5] Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans
    Alexandra R. Cunliffe
    Bradley White
    Julia Justusson
    Christopher Straus
    Renuka Malik
    Hania A. Al-Hallaq
    Samuel G. Armato
    Journal of Digital Imaging, 2015, 28 : 755 - 760
  • [6] Comparison of Two Deformable Registration Algorithms in the Presence of Radiologic Change Between Serial Lung CT Scans
    Cunliffe, Alexandra R.
    White, Bradley
    Justusson, Julia
    Straus, Christopher
    Malik, Renuka
    Al-Hallaq, Hania A.
    Armato, Samuel G., III
    JOURNAL OF DIGITAL IMAGING, 2015, 28 (06) : 755 - 760
  • [7] Pulmonary nodule registration in serial CT scans based on rib anatomy and nodule template matching
    Shi, Jiazheng
    Sahiner, Berkman
    Chan, Heang-Ping
    Hadjiiski, Lubomir
    Zhou, Chuan
    Cascade, Philip N.
    Bogot, Naama
    Kazerooni, Ella A.
    Wu, Yi-Ta
    Wei, Jun
    MEDICAL PHYSICS, 2007, 34 (04) : 1336 - 1347
  • [8] Internet of Medical Things-Based on Deep Learning Techniques for Segmentation of Lung and Stroke Regions in CT Scans
    Han, Tao
    Nunes, Virginia Xavier
    De Freitas Souza, Luis Fabricio
    Marques, Adriell Gomes
    Lima Silva, Iagson Carlos
    Araujo Ferreira Junior, Marcos Aurelio
    Sun, Jinghua
    Reboucas Filho, Pedro P.
    IEEE ACCESS, 2020, 8 (08): : 71117 - 71135
  • [9] Accuracy improvement of lung cancer detection based on spatial statistical analysis of thoracic CT scans
    Takizawa, Hotaka
    Yamamoto, Shinji
    Shiina, Tsuyoshi
    COMPUTER VISION/COMPUTER GRAPHICS COLLABORATION TECHNIQUES, 2007, 4418 : 607 - +
  • [10] A TEXTURE ANALYSIS APPROACH TO ASSESS THE SEVERITY OF ACUTE NORMAL TISSUE CHANGES IN THORACIC CT SCANS FOLLOWING RADIATION THERAPY FOR LUNG CANCER
    Cunliffe, Alexandra
    Armato, Samuel G.
    Straus, Christopher
    Malik, Renuka
    Al-Hallaq, Hania A.
    JOURNAL OF THORACIC ONCOLOGY, 2013, 8 : S969 - S969