关键词
Atmospheric pressure DC arc discharge; Argon/nitrogen plasma; Excitation temperature; Electron density; Thermal equilibrium; INDUCTIVELY-COUPLED PLASMA; ANALYTICAL ATOMIC SPECTROMETRY; POWER INTERRUPTION TECHNIQUE; EXCITATION MECHANISMS; OPTICAL-EMISSION; LINE-INTENSITIES; MIXED-GAS; PARAMETERS; RESPONSES; HYDROGEN;
D O I
10.1007/s11090-015-9637-6
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The effect of nitrogen addition (1-20 %) on atmospheric argon DC arc plasma parameters was investigated. Nitrogen was added to three initial plasma gas compositions: pure argon gas, argon gas with water aerosol, and argon gas with water aerosol containing 0.5 % KCl. Admixtures of nitrogen from 1 up to 10 % (in the case of Ar-N-2-water aerosol plasma) or up to 5 % (in the presence of 0.5 % KCl) produced a more contracted discharge, with larger gradients of electron number density and temperature, as compared to plasma without molecular gas addition. The opposite effect was observed in gas mixtures with 20 % of nitrogen. In that case, the arc core was expanded, and the radial profile of electron density and temperature became flatter as compared to the case of pure argon plasma. The changes in the radial structure of the discharge could be explained by increased thermal conductivity of mixed gas plasma and the presence of molecular ions. Increasing nitrogen content brings plasma closer to thermal equilibrium. To evaluate the effect of nitrogen upon analytic performance of the arc source, limits of detection (LODs) were measured for Zn, Cu, Li, and Rb. In plasma without KCl, the addition of nitrogen resulted in lowering of LODs for Cu, Li and Rb, while the opposite was observed for Zn. In the presence of KCl the addition of nitrogen had little or no effect on LODs for Cu, Li and Rb, while detection limits for Zn were increased.
引用
收藏
页码:1071 / 1095
页数:25
相关论文
共 44 条
[1]   Towards the reduction of matrix effects in inductively coupled plasma mass spectrometry without compromising detection limits: The use of argon-nitrogen mixed-gas plasma [J].
Agatemor, Christian ;
Beauchemin, Diane .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (01) :1-11
[2]   Plasma parameters of an argon DC arc with graphite electrodes [J].
Baronnet, JM ;
Ershov-Pavlov, EA ;
Megy, S .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (19) :2552-2559
[3]   Modeling of a nonequilibrium cylindrical column of a low-current arc discharge [J].
Benilov, MS .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 1999, 27 (05) :1458-1463
[4]  
BLADES MW, 1987, PROG ANAL SPECTROSC, V10, P57
[5]   State-of-the-art and trends of development in analytical atomic spectrometry with inductively coupled plasmas as radiation and ion sources [J].
Broekaert, JAC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (07) :739-751
[6]   Comparative study of an argon plasma and an argon copper plasma produced by an ICP torch at atmospheric pressure based on spectroscopic methods [J].
Bussiere, W. ;
Vacher, D. ;
Menecier, S. ;
Andre, P. .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 2011, 20 (04)
[7]   Achieving non-contracted and non-filamentary rare-gas tubular discharges at atmospheric pressure [J].
Castanos-Martinez, E. ;
Moisan, M. ;
Kabouzi, Y. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (01)
[8]  
Eletskii AV, 1996, PHYS-USP, V39, P1137
[9]   INSTANTANEOUS AND DELAYED-RESPONSES OF LINE-INTENSITIES TO INTERRUPTION OF THE RF POWER IN AN ARGON INDUCTIVELY COUPLED PLASMA [J].
FEY, FHAG ;
STOFFELS, WW ;
VANDERMULLEN, JAM ;
VANDERSIJDE, B ;
SCHRAM, DC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (6-7) :885-900
[10]   Thermal plasma modelling [J].
Gleizes, A ;
Gonzalez, JJ ;
Freton, P .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (09) :R153-R183