Towards automated electroencephalography-based Alzheimer's disease diagnosis using portable low-density devices

被引:54
作者
Cassani, Raymundo [1 ]
Falk, Tiago H. [1 ]
Fraga, Francisco J. [2 ]
Cecchi, Marco [3 ]
Moore, Dennis K. [3 ]
Anghinah, Renato [4 ]
机构
[1] Univ Quebec, Inst Natl Rech Sci, Ctr Energie Mat Telecommun, Montreal, PQ, Canada
[2] Univ Fed ABC, Engn Modelling & Appl Social Sci Ctr, Sao Paulo, Brazil
[3] Neuronetrix, Louisville, KY USA
[4] Univ Sao Paulo, Sch Med, Reference Ctr Behav Disturbances & Dementia, Sao Paulo, Brazil
基金
加拿大自然科学与工程研究理事会; 巴西圣保罗研究基金会;
关键词
Alzheimer's disease (AD); Electroencephalography (EEG); Portable; Low-density; Amplitude modulation; Spectral power; Coherence; Diagnosis; MILD COGNITIVE IMPAIRMENT; OSCILLATORY RESPONSES; MEMORY TASK; EEG; ARTIFACTS; CRITERIA; SIGNALS;
D O I
10.1016/j.bspc.2016.12.009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Today, Alzheimer's disease (AD) diagnosis is carried out using subjective mental status examinations assisted in research by scarce and expensive neuroimaging scans and invasive laboratory tests; all of which render the diagnosis time-consuming, geographically confined and costly. Driven by these limitations, quantitative analysis of electroencephalography (EEG) has been proposed as a non-invasive and more convenient technique to study AD. Published works on EEG-based AD diagnosis typically share two main characteristics: EEG is manually selected by experienced clinicians to discard artefacts that affect AD diagnosis, and reliance on EEG devices with 20 or more electrodes. Recent work, however, has suggested promising results by using automated artefact removal (AAR) algorithms combined with medium-density EEG setups. Over the last couple of years, however, low-density, portable EEG devices have emerged, thus opening the doors for low-cost AD diagnosis in low-income countries and remote regions, such as the Canadian Arctic. Unfortunately, the performance of automated diagnostic solutions based on low-density portable devices is still unknown. The work presented here aims to fill this gap. We propose an automated EEG-based AD diagnosis system based on AAR and a low-density (7- channel) EEG setup. EEG data was acquired during resting-awake protocol from control and AD participants. After AAR, common EEG features, spectral power and coherence, are computed along with the recently proposed amplitude-modulation features. The obtained features are used for training and testing of the proposed diagnosis system. We report and discuss the results obtained with such system and compare the obtained performance with results published in the literature using higher-density EEG layouts. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 271
页数:11
相关论文
共 50 条
  • [1] Abdi H., 2006, ENCY MEASUREMENT STA, P103
  • [2] Alzheimer's disease: Models of computation and analysis of EEGs
    Adeli, H
    Ghosh-Dastidar, S
    Dadmehr, N
    [J]. CLINICAL EEG AND NEUROSCIENCE, 2005, 36 (03) : 131 - 140
  • [3] [Anonymous], 2015, ALZH DIS FACTS FIG
  • [4] [Anonymous], GLOB IMP DEM 2013 20
  • [5] [Anonymous], 2006, GUID 6 PROP STAND MO
  • [6] [Anonymous], DEM PUBL HLTH PRIOR
  • [7] EEG artifact removal-state-of-the-art and guidelines
    Antonio Urigueen, Jose
    Garcia-Zapirain, Begona
    [J]. JOURNAL OF NEURAL ENGINEERING, 2015, 12 (03)
  • [8] White-Matter Lesions Along the Cholinergic Tracts are Related to Cortical Sources of EEG Rhythms in Amnesic Mild Cognitive Impairment
    Babiloni, Claudio
    Pievani, Michela
    Vecchio, Fabrizio
    Geroldi, Cristina
    Eusebi, Fabrizio
    Fracassi, Claudia
    Fletcher, Evan
    De Carli, Charles
    Boccardi, Marina
    Rossini, Paolo Maria
    Frison, Giovanni B.
    [J]. HUMAN BRAIN MAPPING, 2009, 30 (05) : 1431 - 1443
  • [9] Barua B., 2020, Waiting Your Turn: Wait Times for Health Care in Canada, 2020 Report
  • [10] Ben-Hur A, 2010, METHODS MOL BIOL, V609, P223, DOI 10.1007/978-1-60327-241-4_13